Mercury-plated iridium-based microelectrode arrays for trace metals detection by voltammetry: Optimum conditions and reliability

被引:115
作者
Belmont, C
Tercier, ML
Buffle, J
Fiaccabrino, GC
KoudelkaHep, M
机构
[1] DEPT INORGAN ANALYT & APPL CHEM,CH-1211 GENEVA 4,SWITZERLAND
[2] UNIV NEUCHATEL,INST MICROTECHNOL,CH-2000 NEUCHATEL,SWITZERLAND
关键词
mercury-plated iridium-based microelectrode arrays; nanotechnology; stripping voltammetry; trace metals; reliability;
D O I
10.1016/0003-2670(96)00116-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric microsensor for the detection of trace metals in the low or sub nanomolar range is presented. It is obtained by successively evaporating iridium (2000 Angstrom) and Si3N4 (2000 Angstrom) on a silicon wafer, followed by a photolithographic pattering procedure. It consists of an array of 10x10 iridium microdisc electrodes with a recessed depth of 0.2 mu m, separated by 50 or 150 mu m. The electrical contacts are isolated by a layer of Agolit or Epoxy resin. Scanning electron microscopy and Atomic force microscopy have been used to control the regularity of the microelectrode array geometry and morphology. For the analysis of trace metals, mercury is deposited on the iridium-based microelectrode array. A given array is able to sustain the operations of Hg deposition/dissolution at least 10 times. The reliability of the mercury-plated iridium-based microelectrode arrays has been tested by a series of systematic Square Wave Anodic Striping Voltammetry (SWASV) analyses in synthetic solutions of lead and cadmium ions in the concentration range 1-10 nM. Repeated measurements over long periods of time on a given mercury layer showed good stability when the Epoxy resin was used and good reproducibility (+/-4%) for at least 5 h. A good reproducibility was also found between different arrays. Finally, the mercury-plated iridium-based microelectrode arrays were applied to the lead and cadmium speciation in river water, by direct SWASV measurements, without any separation. A detection limit of 50 pM was established for a preconcentration time of 15 min. The results were compared with other techniques, in particular a similar procedure using a single Hg-plated Ir-based microelectrode.
引用
收藏
页码:203 / 214
页数:12
相关论文
共 26 条
[1]   MULTICHANNEL ELECTROCHEMICAL DETECTION WITH A MICROELECTRODE ARRAY IN FLOWING STREAMS [J].
AOKI, A ;
MATSUE, T ;
UCHIDA, I .
ANALYTICAL CHEMISTRY, 1992, 64 (01) :44-49
[2]  
BERZINS T, 1951, J AM CHEM SOC, V73, P555
[3]   A COMPARISON OF THE CHRONOAMPEROMETRIC RESPONSE AT INLAID AND RECESSED DISK MICROELECTRODES [J].
BOND, AM ;
LUSCOMBE, D ;
OLDHAM, KB ;
ZOSKI, CG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 249 (1-2) :1-14
[4]   PREPARATION OF A MERCURY DISK MICROELECTRODE BASED ON SOLID SILVER AMALGAM [J].
CISZKOWSKA, M ;
DONTEN, M ;
STOJEK, Z .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :4112-4115
[5]   LINEAR SWEEP AND CYCLIC VOLTAMMETRY FOR METAL-DEPOSITION AT SOLID AND MERCURY MICROELECTRODES FROM SOLUTIONS WITH AND WITHOUT SUPPORTING ELECTROLYTE [J].
DANIELE, S ;
BALDO, MA ;
CORBETTA, M ;
MAZZOCCHIN, GA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 379 (1-2) :261-270
[6]   ADSORPTIVE STRIPPING VOLTAMMETRY ON MERCURY-COATED CARBON-FIBER ULTRAMICROELECTRODES [J].
DELPOZO, JA ;
GARCIA, AC ;
BLANCO, PT .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :101-109
[7]  
FERRETTI R, 1994, THESIS U GENEVE
[8]  
GUMINSKI C, 1986, SOLUBILITY DATA SERI
[9]   TOWARDS AN INTEGRATED ELECTRONIC NOSE USING CONDUCTING POLYMER SENSORS [J].
HATFIELD, JV ;
NEAVES, P ;
HICKS, PJ ;
PERSAUD, K ;
TRAVERS, P .
SENSORS AND ACTUATORS B-CHEMICAL, 1994, 18 (1-3) :221-228
[10]   MULTICHANNEL AMPEROMETRIC DETECTION SYSTEM FOR LIQUID-CHROMATOGRAPHY AND FLOW-INJECTION ANALYSIS [J].
HOOGVLIET, JC ;
REIJN, JM ;
VANBENNEKOM, WP .
ANALYTICAL CHEMISTRY, 1991, 63 (21) :2418-2423