Computationally efficient methodology for analysis of faulted power systems with series-compensated transmission lines: A phase coordinate approach

被引:28
作者
Gajbhiye, Rajeev Kumar [1 ]
Gopi, Beeram [1 ]
Kulkarni, Pushpa [1 ]
Soman, S. A. [1 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Bombay 400076, Maharashtra, India
关键词
current inversion; fault analysis; metal-oxide varistor (MOV); series capacitor; Thevenin equivalent circuit; voltage inversion;
D O I
10.1109/TPWRD.2007.915966
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 [电气工程]; 0809 [电子科学与技术];
摘要
A capacitor in series with a transmission line is protected from overvoltage due to a large fault current by a nonlinear metal-oxide varistor (MOV) connected in parallel. Fault analysis, as well as the evaluation of performance of the transmission protection system, in the presence of MOV action becomes complex because 1) v-i characteristics of the MOV are nonlinear; 2) unsymmetrical MOV action for unsymmetrical faults will introduce coupling in sequence networks; and 3) MOV action will influence voltage or current inversion phenomenon. This paper presents a computationally efficient and simple methodology for fault analysis wherein the linear part of the network is modeled by an equivalent multiport Thevenin network. The proposed approach handles nonlinearity in fault analysis efficiently. It also provides an elegant approach to model unbalance in a network due to MOV action. The proposed approach can be used to determine relays prone to voltage or current inversion. Results on a real-life 716-bus Indian system illustrate the efficiency of the proposed approach.
引用
收藏
页码:873 / 880
页数:8
相关论文
共 15 条
[1]
Anderson PM, 1999, POWER SYSTEM PROTECT
[2]
Analysis of faulted power systems by phase coordinates [J].
Berman, A ;
Xu, W .
IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (02) :587-595
[3]
MODELING MOV-PROTECTED SERIES CAPACITORS FOR SHORT-CIRCUIT STUDIES [J].
COURSOL, M ;
NGUYEN, CT ;
LORD, R ;
DO, XD .
IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (01) :448-453
[4]
GAJBHIYE RK, 2005, ANAL FAULTED POWER S, P1
[5]
A LINEARIZED MODEL FOR MOV-PROTECTED SERIES CAPACITORS [J].
GOLDSWORTHY, DL .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1987, 2 (04) :953-958
[6]
GOPALAKRISHNAN A, 2001, DEV POWER SYSTEM PRO, P363
[7]
*IEEE, 1998, SER CAP BANK PROT
[8]
ANALYSIS OF UNBALANCED POLYPHASE NETWORKS BY METHOD OF PHASE CO-ORDINATES .1. SYSTEM REPRESENTATION IN PHASE FRAME OF REFERENCE [J].
LAUGHTON, MA .
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1968, 115 (08) :1163-&
[9]
ANALYSIS OF UNBALANCED POLYPHASE NETWORKS BY METHOD OF PHASE CO-ORDINATES .2. FAULT ANALYSIS [J].
LAUGHTON, MA .
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1969, 116 (05) :857-&
[10]
A COMPUTATIONALLY EFFICIENT MOV MODEL FOR SERIES COMPENSATION STUDIES [J].
LUCAS, JR ;
MCLAREN, PG .
IEEE TRANSACTIONS ON POWER DELIVERY, 1991, 6 (04) :1491-1497