Miniaturized measurement system for ammonia in air

被引:36
作者
Timmer, BH
van Delft, KM
Otjes, RP
Olthuis, W
van den Berg, A
机构
[1] Univ Twente, MESA Res Inst, NL-7500 AE Enschede, Netherlands
[2] Energy Res Ctr Netherlands, Petten, Netherlands
关键词
gaseous ammonia sensor; microfluidics;
D O I
10.1016/j.aca.2003.09.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a miniaturized ammonia sensor made using microsystem technology is described. Gas is sampled in a sampler comprising two opposite channels separated by a gas permeable, water repellent polypropylene membrane. Subsequently, the acid sample solution is pumped into a selector where an alkaline solution is added to ionize all sampled ambient acid gasses, resulting in an enhanced selectivity. In the selector, the ammonia can diffuse through a second membrane into a purified water stream where an electrolyte conductivity sensor quantifies the resulting ammonium concentration. The realized system is shown to be selective enough not to be influenced by normal ambient carbon dioxide concentrations. Experiments with a gas flow of 3 ml/min, containing ammonia concentrations ranging from 9.8 to 0.3 ppm in a nitrogen carrier flow, into a 15 mul/min sample solution flow and finally into a 5 mul/min purified water stream have been carried out and show that the system is sensitive to ammonia concentration below I ppm. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:137 / 143
页数:7
相关论文
共 25 条
[1]   Respiratory ammonia output and blood ammonia concentration during incremental exercise [J].
Ament, W ;
Huizenga, JR ;
Kort, E ;
van der Mark, TW ;
Grevink, RG ;
Verkerke, GJ .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1999, 20 (02) :71-77
[2]   A highly selective ammonia gas sensor using surface-ruthenated zinc oxide [J].
Aslam, M ;
Chaudhary, VA ;
Mulla, IS ;
Sainkar, SR ;
Mandale, AB ;
Belhekar, AA ;
Vijayamohanan, K .
SENSORS AND ACTUATORS A-PHYSICAL, 1999, 75 (02) :162-167
[3]   Field measurement of acid gases and soluble anions in atmospheric particulate matter using a parallel plate wet denuder and an alternating filter-based automated analysis system [J].
Boring, CB ;
Al-Horr, R ;
Genfa, Z ;
Dasgupta, PK ;
Martin, MW ;
Smith, WF .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1256-1268
[4]   Ammonia detection and monitoring with photofragmentation fluorescence [J].
Buckley, SG ;
Damm, CJ ;
Vitovec, WM ;
Sgro, LA ;
Sawyer, RF ;
Koshland, CP ;
Lucas, D .
APPLIED OPTICS, 1998, 37 (36) :8382-8391
[5]   Acrylic acid doped polyaniline as an ammonia sensor [J].
Chabukswar, VV ;
Pethkar, S ;
Athawale, AA .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (03) :657-663
[6]  
CHANG R, 2000, U SCI BOOKS, pCH11
[7]   Instrument development and application in studies and monitoring of ambient ammonia [J].
Erisman, JW ;
Otjes, R ;
Hensen, A ;
Jongejan, P ;
van den Bulk, P ;
Khlystov, A ;
Möls, H ;
Slanina, S .
ATMOSPHERIC ENVIRONMENT, 2001, 35 (11) :1913-1922
[8]   Breath ammonia measurement in Helicobacter pylori infection [J].
Kearney, DJ ;
Hubbard, T ;
Putnam, D .
DIGESTIVE DISEASES AND SCIENCES, 2002, 47 (11) :2523-2530
[9]  
LAEHDESMAEKI I, 1996, TALANTA, V43, P125
[10]   MEASUREMENT OF ATMOSPHERIC SULFUR-DIOXIDE BY DIFFUSION SCRUBBER COUPLED ION CHROMATOGRAPHY [J].
LINDGREN, PF ;
DASGUPTA, PK .
ANALYTICAL CHEMISTRY, 1989, 61 (01) :19-24