Primary renal artery stenting: Characteristics and outcomes after 363 procedures

被引:199
作者
Lederman, RJ
Mendelsohn, FO
Santos, R
Phillips, HR
Stack, RS
Crowley, JJ
机构
[1] Duke Univ, Med Ctr, Dept Med, Div Cardiol, Durham, NC 27710 USA
[2] Univ Michigan Hlth Syst, Dept Internal Med, Div Cardiol, Ann Arbor, MI USA
关键词
D O I
10.1067/mhj.2001.116958
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Stenting improves the acute results of percutaneous balloon angioplasty for atherosclerotic renal artery stenosis. Predictors of benefit and angiographic restenosis are not well understood. We describe the technical and clinical success of renal artery stenting in a large consecutive series of patients with hypertension or renal insufficiency. We identify clinical, procedural, and anatomic factors that might influence outcome, restenosis, and survival. Methods Primary renal artery stenting was performed in 300 consecutive patients who underwent 363 stent procedures in 358 arteries. Angiograms were analyzed quantitatively. Clinical and angiographic follow-up data are available after a median of 16.0 months. Results At baseline, 87% of patients had hypertension, and 37% had chronic renal insufficiency. The mean age was 70 years (interquartile range 63.1-74.6) years. The stenosis was unilateral in 49% and bilateral in 48% and involved a solitary functioning kidney in 3.6%. The stenting procedure was successful in all attempts. There were no procedural deaths or emergency renal surgical procedures. Postprocedure azotemia was seen in 45 of 363 (12%) procedures but persisted in only 6 patients (2%), all of whom had baseline renal insufficiency. Systolic and diastolic blood pressures were significantly reduced (systolic blood pressure from 164.0 +/- 28.7 to 142.4 +/- 19.1 mm Hg, P <.001). At follow-up, 70% of patients had improved blood pressure control regardless of renal function. In patients with baseline renal insufficiency, 19% had improvement in serum creatinine levels at follow-up, 54% had stabilization, and 27% had deterioration. Follow-up mortality was 10% and was predicted by baseline creatinine levels (odds ratio 1.72 for each 1 mg/dL creatinine increment, 95% confidence interval 1. 13-2.49) and extent of coronary artery disease (odds ratio 1.66 for each diseased coronary artery, 95% confidence interval 1.03-2.67). Angiographic restenosis was found in 21% of 102 patients overall and was less common (12%) in arteries with a reference caliber >4.5 mm (P<.01 vs caliber <4.5 mm). Neither poststenotic dilation nor severity of angiographic stenosis predicted clinical outcome. Conclusions Primary renal artery stenting can be performed safely with nearly uniform technical success. The majority of patients with hypertension or renal insufficiency derive benefit. Follow-up mortality is 5-fold higher in patients with baseline renal insufficiency. Clinical and angiographic features did not predict blood pressure or renal functional outcome. Restenosis is more common in renal arteries with a reference caliber less than 4.5 mm.
引用
收藏
页码:314 / 323
页数:10
相关论文
共 48 条
[1]  
Ahuja Ratan K., 1999, Journal of the American College of Cardiology, V33, p42A
[2]  
[Anonymous], 1991, JAMA, V265, P3255
[3]  
[Anonymous], 1997, ARCH INTERN MED, V157, P2413, DOI [10.1001/archinte.1997.00440420033005, DOI 10.1001/ARCHINTE.1997.00440420033005]
[4]   ACCURACY OF INDIVIDUAL AND PANEL VISUAL INTERPRETATIONS OF CORONARY ARTERIOGRAMS - IMPLICATIONS FOR CLINICAL DECISIONS [J].
BEAUMAN, GJ ;
VOGEL, RA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (01) :108-113
[5]  
BERGAN JJ, 1992, ARCH SURG-CHICAGO, V127, P1119
[6]   Treatment of ostial renal-artery stenoses with vascular endoprostheses after unsuccessful balloon angioplasty [J].
Blum, U ;
Krumme, B ;
Flugel, P ;
Gabelmann, A ;
Lehnert, T ;
BuitragoTellez, C ;
Schollmeyer, P ;
Langer, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (07) :459-465
[7]   Treatment of renal angioplasty failure by percutaneous renal artery stenting with Palmaz stents: Midterm technical and clinical results [J].
Boisclair, C ;
Therasse, E ;
Oliva, VL ;
Soulez, G ;
Bui, BT ;
Querin, S ;
Robillard, P .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (01) :245-251
[8]   RENAL-ARTERY ANGIOPLASTY - TECHNICAL RESULTS AND CLINICAL OUTCOME IN 320 PATIENTS [J].
BONELLI, FS ;
MCKUSICK, MA ;
TEXTOR, SC ;
KOS, PB ;
STANSON, AW ;
JOHNSON, CM ;
SHEEDY, PF ;
WELCH, TJ ;
SCHIRGER, A .
MAYO CLINIC PROCEEDINGS, 1995, 70 (11) :1041-1052
[9]   THE DURABILITY OF DIFFERENT RECONSTRUCTIVE TECHNIQUES FOR ATHEROSCLEROTIC RENAL-ARTERY DISEASE [J].
CAMBRIA, RP ;
BREWSTER, DC ;
LITALIEN, GJ ;
MONCURE, A ;
DARLING, RC ;
GERTLER, JP ;
LAMURAGLIA, GM ;
ATAMIAN, S ;
ABBOTT, WM .
JOURNAL OF VASCULAR SURGERY, 1994, 20 (01) :76-87
[10]   Risk of atrophy in kidneys with atherosclerotic renal artery stenosis [J].
Caps, MT ;
Zierler, RE ;
Polissar, NL ;
Bergelin, RO ;
Beach, KW ;
Cantwell-Gab, K ;
Casadei, A ;
Davidson, RC ;
Strandness, ED .
KIDNEY INTERNATIONAL, 1998, 53 (03) :735-742