Immobilized glycerol-based liquid membranes in hollow fibers for selective CO2 separation from CO2-N2 mixtures

被引:46
作者
Chen, H
Obuskovic, G
Majumdar, S
Sirkar, KK [1 ]
机构
[1] New Jersey Inst Technol, Dept Chem Engn Chem & Environm Sci, Newark, NJ 07102 USA
[2] NJIT, Ctr Membrane Technol, Newark, NJ USA
基金
美国国家航空航天局;
关键词
fiber membrane; facilitated transport; CO2; separation; liquid membrane; glycerol;
D O I
10.1016/S0376-7388(00)00581-0
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Glycerol-based liquid membranes immobilized in the pores of hydrophilic microporous hollow fibers have been studied for selective separation of CO2 from a mixed gas (CO2, N-2) feed having low concentrations of CO2 characteristic of gases encountered in space walk and space cabin atmosphere. The immobilized liquid membranes (ILMs) investigated consist of sodium carbonate-glycerol or glycine-Na-glycerol solution. Based on the performances of such liquid membranes in flat hydrophilic porous substrates [Chen et al., Ind. Eng. Chem. Res. 38 (1999) 3489; Chen et al., Ind. Eng. Chem. Res. 39 (2000) 2447], hollow fiber-based ILMs were studied at selected CO2 partial pressure differentials (Deltap(CO2), range 0.36-0.50 cmHg), relative humidities (RH range 45-100%), as well as carrier concentrations. The sodium carbonate concentration was primarily 1.0 mol/dm(3): the glycine-Na concentration was 3.0 mol/dm(3). The sweep gas was always dry helium and it flowed on the shell side. Very high CO2/N-2 selectivities were observed with porous polysulfone microfiltration membranes as substrate. As in the case of flat film-based ILMs (see references above), feed side RH is an important factor determining the ILM performances. Generally, lower permeances and greater CO2/N-2 selectivity values were observed at lower feed stream RHs. When the feed side average RH = 60%, p(CO2.f) = 0.005 arm and glycine-Na concentration was 3.0 M, the CO2/N-2 Separation factor observed was over 5000. Prolonged runs lasting for 300 h showed that the hollow fiber-based ILM permeation performances were stable. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:75 / 88
页数:14
相关论文
共 11 条
[1]   GAS PERMEATION AND SEPARATION BY AQUEOUS MEMBRANES IMMOBILIZED ACROSS THE WHOLE THICKNESS OR IN A THIN-SECTION OF HYDROPHOBIC MICROPOROUS CELGARD FILMS [J].
BHAVE, RR ;
SIRKAR, KK .
JOURNAL OF MEMBRANE SCIENCE, 1986, 27 (01) :41-61
[2]   Removal of water vapor and VOCs from nitrogen in a hydrophilic hollow fiber gel membrane permeator [J].
Cha, JS ;
Li, R ;
Sirkar, KK .
JOURNAL OF MEMBRANE SCIENCE, 1996, 119 (01) :139-153
[3]   Selective CO2 separation from CO2-N2 mixtures by immobilized carbonate-glycerol membranes [J].
Chen, H ;
Kovvali, AS ;
Majumdar, S ;
Sirkar, KK .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1999, 38 (09) :3489-3498
[4]   Selective CO2 separation from CO2-N2 mixtures by immobilized glycine-Na-glycerol membranes [J].
Chen, H ;
Kovvali, AS ;
Sirkar, KK .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2000, 39 (07) :2447-2458
[5]  
Davidson D L, 1993, Seizure, V2, P1, DOI 10.1016/S1059-1311(05)80095-0
[6]  
JEFFREYS GV, 1964, T I CHEM ENG-LOND, V42, pT118
[7]  
Matsuyama H, 1996, ACS SYM SER, V642, P252
[8]  
Meldon J., 1986, AICHE S SER, V248, P114
[9]   FACILITATED TRANSPORT OF CARBON-DIOXIDE - A REVIEW [J].
MELDON, JH ;
STROEVE, P ;
GREGOIRE, CE .
CHEMICAL ENGINEERING COMMUNICATIONS, 1982, 16 (1-6) :263-300
[10]   SELECTIVE CO2 SEPARATION FROM CO2/C2H6 MIXTURES BY IMMOBILIZED DIETHANOLAMINE PEG MEMBRANES [J].
SAHA, S ;
CHAKMA, A .
JOURNAL OF MEMBRANE SCIENCE, 1995, 98 (1-2) :157-171