In vivo dosimetry during external photon beam radiotherapy

被引:183
作者
Essers, M
Mijnheer, BJ
机构
[1] Univ Rotterdam Hosp, Hosp Dijkzigt, Dept Radiat Oncol, Div Clin Phys & Instrumentat,Daniel den Hoed Canc, NL-3075 EA Rotterdam, Netherlands
[2] Antoni Van Leeuwenhoek Huis, Netherlands Canc Inst, Dept Radiotherapy, Amsterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1999年 / 43卷 / 02期
关键词
in vivo dosimetry; quality assurance; diodes; TLDs; photon beams;
D O I
10.1016/S0360-3016(98)00341-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
In this critical review of the current practice of patient dose verification, we first demonstrate that a high accuracy (about 1-2%, 1 SD) can be obtained. Accurate in vivo dosimetry is possible if diodes and thermoluminescence dosimeters (TLDs), the main detector types in use for in vivo dosimetry, are carefully calibrated and the factors influencing their sensitivity are taken into account. Various methods and philosophies for applying patient dose verification are then evaluated: the measurement of each field for each fraction of each patient, a limited number of checks for all patients, or measurements of specific patient groups, for example, during total body irradiation (TBI) or conformal radiotherapy. The experience of a number of centers is then presented, providing information on the various types of errors detected by in vivo dosimetry, including their frequency and magnitude. From the results of recent studies it can be concluded that in centers having modern equipment with verification systems as well as comprehensive quality assurance (QA) programs, a systematic error larger than 5% in dose delivery is still present for 0.5-1% of the patient treatments. In other studies, a frequency of 3-10% of errors was observed for specific patient groups or when no verification system was present at the accelerator. These results were balanced against the additional manpower and other resources required for such a QA program. It could be concluded that patient dose verification should be an essential part of a QA program in a radiotherapy department, and plays a complementary role to treatment-sheet double checking. As the radiotherapy community makes the transition from the conventional two-dimensional (2D) to three-dimensional (3D) conformal and intensity modulated dose delivery, it is recommended that new treatment techniques be checked systematically for a few patients, and to perform in vivo dosimetry a few times for each patient for situations where errors in dose delivery should be minimized. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:245 / 259
页数:15
相关论文
共 126 条
[1]   Dose perturbations due to in vivo dosimetry with diodes [J].
Alecu, R ;
Feldmeier, JJ ;
Alecu, M .
RADIOTHERAPY AND ONCOLOGY, 1997, 42 (03) :289-291
[2]  
Aletti P, 1994, Bull Cancer Radiother, V81, P453
[3]   A COMPARISON OF SEMICONDUCTOR AND THERMOLUMINESCENT DOSIMETERS FOR INVIVO DOSIMETRY [J].
AUKETT, RJ .
BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (766) :947-952
[4]   RADIOTHERAPY OF LYMPH-NODE METASTASES IN PATIENTS WITH SQUAMOUS-CELL CARCINOMA OF THE HEAD AND NECK REGION [J].
BARTELINK, H ;
BREUR, K ;
HART, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1982, 8 (06) :983-989
[5]  
BASCUAS JL, 1977, J RADIOL ELEC MED N, V58, P701
[6]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .2. PROPERTIES AND MEASUREMENTS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1901-1913
[7]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .1. PHYSICAL CHARACTERISTICS AND THEORETICAL CONSIDERATIONS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1883-1900
[8]   TRANSFER ERRORS OF PLANNING CT TO SIMULATOR - A POSSIBLE SOURCE OF SETUP INACCURACIES [J].
BEL, A ;
BARTELINK, H ;
VIJLBRIEF, RE ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1994, 31 (02) :176-180
[9]   RADIOBIOLOGICAL CONSIDERATIONS IN THE DESIGN OF CLINICAL-TRIALS [J].
BENTZEN, SM .
RADIOTHERAPY AND ONCOLOGY, 1994, 32 (01) :1-11
[10]   QUALITY ASSURANCE IN RADIATION-THERAPY - SYSTEMATIC EVALUATION OF ERRORS DURING THE TREATMENT EXECUTION [J].
BLANCO, S ;
LOPEZBOTE, MA ;
DESCO, M .
RADIOTHERAPY AND ONCOLOGY, 1987, 8 (03) :253-261