New methods for fully automated isotope ratio determination from hydrogen at the natural abundance level

被引:42
作者
Brand, WA
Avak, H
Seedorf, R
Hofmann, D
Conradi, T
机构
[1] UFZ HELMHOLTZ CTR ENVIRONM RES, LEIPZIG, GERMANY
[2] UNIV BREMEN, BREMEN, GERMANY
关键词
chromium; deuterium; equilibration; hydrogen; IRMS; isotope ratios; mass spectrometry; water;
D O I
10.1080/10256019608036319
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A variety of methods for measurement of H-2/H-1 from H-2 are evaluated for their ability to be fully automated and for applicability to automated isotopic analysis of water and organic compounds. Equilibration of water with H-2 gas with the aid of a platinum catalyst has been commercialized into a fully automated sample preparation device. A second and newer technique, involving injecting water, methane, or other volatile organic compounds onto hot chromium in a reactor attached to the dual inlet system of a gas isotope ratio mass spectrometer, can be integrated with a conventional GC-autosampler to allow automated analysis of a variety of substrates. Both techniques result in precisions around 1 parts per thousand(delta notation) on the VSMOW scale, and are fast and accurate, and with appropriate mass spectrometers require only negligible scaling for the SLAP/VSMOW difference. Several experimental methods which show considerable promise employ ''isotope ratio monitoring'' (irm) inlet systems, in which a carrier gas is used for transport of H-2 to the mass spectrometer. Any such method has to address the problem of He ions corrupting the measurement of the H-2 ions. One such approach uses a heated palladium membrane for selective introduction of H-2 into the mass spectrometer, and a second involves modifications to the ion optics to control the stray helium ions. Both approaches have significant limitations that must be overcome before irm techniques can be used in routine applications, in particular for measuring hydrogen isotopes From GC effluents (irm-GCMS).
引用
收藏
页码:263 / 273
页数:11
相关论文
共 14 条
[1]  
AVAK H, 1995, 11 FINN MAT
[2]   CONVERSION OF HYDROGENIC MATERIALS TO HYDROGEN FOR ISOTOPIC ANALYSIS [J].
BIGELEISEN, J ;
PERLMAN, ML ;
PROSSER, HC .
ANALYTICAL CHEMISTRY, 1952, 24 (08) :1356-1357
[3]  
BRAND WA, 1989, ADV MASS SPECTROM B, V11, P1800
[4]   REDUCTION OF WATER WITH ZINC FOR HYDROGEN ISOTOPE ANALYSIS [J].
COLEMAN, ML ;
SHEPHERD, TJ ;
DURHAM, JJ ;
ROUSE, JE ;
MOORE, GR .
ANALYTICAL CHEMISTRY, 1982, 54 (06) :993-995
[5]   IMPROVEMENTS IN THE GASEOUS-HYDROGEN WATER EQUILIBRATION TECHNIQUE FOR HYDROGEN ISOTOPE RATIO ANALYSIS [J].
COPLEN, TB ;
WILDMAN, JD ;
CHEN, J .
ANALYTICAL CHEMISTRY, 1991, 63 (09) :910-912
[6]   AN IMPROVED TECHNIQUE FOR THE H-2 H-1 ANALYSIS OF URINES FROM DIABETIC VOLUNTEERS [J].
COPLEN, TB ;
HARPER, IT .
BIOLOGICAL MASS SPECTROMETRY, 1994, 23 (07) :437-439
[7]   VARIATION OF O-18 CONTENT OF WATERS FROM NATURAL SOURCES [J].
EPSTEIN, S ;
MAYEDA, T .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1953, 4 (05) :213-224
[8]   DEUTERIUM CONTENT OF NATURAL WATERS AND OTHER SUBSTANCES [J].
FRIEDMAN, I .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1953, 4 (1-2) :89-103
[9]  
GEHRE M, UNPUB METHODICAL STU
[10]   STANDARDS FOR STABLE ISOTOPE MEASUREMENTS IN NATURAL COMPOUNDS [J].
GONFIANTINI, R .
NATURE, 1978, 271 (5645) :534-536