Determinants of variability of protein content, volume and pH of exhaled breath condensate

被引:47
作者
Bloemen, K.
Lissens, G.
Desager, K.
Schoeters, G.
机构
[1] Flemish Inst Technol Res, VITO, Environm Toxicol Unit, B-2000 Antwerp, Belgium
[2] Univ Antwerp Hosp, Dept Pediat, Antwerp, Belgium
关键词
exhaled breath condensate; pH; total protein concentration; variability; volume;
D O I
10.1016/j.rmed.2006.10.008
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Collection of exhaled breath condensate (EBC) is a simple and noninvasive method to obtain information on the respiratory system. Different mediators can be determined in EBC. However, determinants of variability are not well described. The aim of this study was to evaluate variability of pH, volume and protein concentration of EBC between individuals and between sampling times. Therefore, EBC was collected from 20 healthy volunteers on two different days. Median pH for all samples, measured 5 min after collection without deaeration, was 6.17. Median volume was 1.70ml and median total protein concentration was 1.02 mu g/ml. Coefficients of variation were 5.17%, 21.84% and 37.93%, respectively. No intra- or interday variability could be found, except for the first collection time. Between individuals, significant differences were observed for all three mediators. Age, height and gender can explain part of this variation. In conclusion, no significant difference between sampling times on the same day or on different days was obtained for pH, volume and total protein concentration, provided that subjects are experienced in collecting EBC. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1331 / 1337
页数:7
相关论文
共 20 条
[1]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]
Reproducibility of exhaled breath condensate pH in chronic obstructive pulmonary disease [J].
Borrill, Z ;
Starkey, C ;
Vestbo, J ;
Singh, D .
EUROPEAN RESPIRATORY JOURNAL, 2005, 25 (02) :269-274
[3]
High levels of interleukin-6 in the exhaled breath condensate of patients with COPD [J].
Bucchioni, E ;
Kharitonov, SA ;
Allegra, L ;
Barnes, PJ .
RESPIRATORY MEDICINE, 2003, 97 (12) :1299-1302
[4]
CAIN D, 2002, EUR RESPIR J, V20, pP3280
[5]
CAREY KW, 2001, CIRCADIAN VARIATION
[6]
Increased inflammatory markers in the exhaled breath condensate of cigarette smokers [J].
Carpagnano, GE ;
Kharitonov, SA ;
Foschino-Barbaro, MP ;
Resta, O ;
Gramiccioni, E ;
Barnes, PJ .
EUROPEAN RESPIRATORY JOURNAL, 2003, 21 (04) :589-593
[7]
The effects of volatile salivary acids and bases on exhaled breath condensate pH [J].
Effros, RM ;
Casaburi, R ;
Su, J ;
Dunning, M ;
Torday, J ;
Biller, J ;
Shaker, R .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2006, 173 (04) :386-392
[8]
Variability of nitric oxide metabolites in exhaled breath condensate [J].
Franklin, P ;
Moeller, A ;
Hall, GL ;
Horak, F ;
Patterson, H ;
Stick, SM .
RESPIRATORY MEDICINE, 2006, 100 (01) :123-129
[9]
Markers of inflammation in exhaled breath condensate of young healthy smokers [J].
Garey, KW ;
Nenhauser, MM ;
Robbins, RA ;
Danziger, LH ;
Rubinstein, I .
CHEST, 2004, 125 (01) :22-26
[10]
Exhaled breath condensate cytokine patterns in chronic obstructive pulmonary disease [J].
Gessner, C ;
Scheibe, R ;
Wötzel, M ;
Hammerschmidt, S ;
Kuhn, H ;
Engelmann, L ;
Hoheisel, G ;
Gillissen, A ;
Sack, U ;
Wirtz, H .
RESPIRATORY MEDICINE, 2005, 99 (10) :1229-1240