Multi-residue analytical method for human pharmaceuticals and synthetic hormones in river water and sewage effluents by solid-phase extraction and liquid chromatography-tandem mass spectrometry
被引:184
作者:
Al-Odaini, Najat Ahmed
论文数: 0引用数: 0
h-index: 0
机构:
Univ Putra Malaysia, Fac Environm Studies, Ctr Excellence Environm Forens, Upm Serdang 43400, Selangor, MalaysiaUniv Putra Malaysia, Fac Environm Studies, Ctr Excellence Environm Forens, Upm Serdang 43400, Selangor, Malaysia
Al-Odaini, Najat Ahmed
[1
]
Zakaria, Mohamad Pauzi
论文数: 0引用数: 0
h-index: 0
机构:
Univ Putra Malaysia, Fac Environm Studies, Ctr Excellence Environm Forens, Upm Serdang 43400, Selangor, MalaysiaUniv Putra Malaysia, Fac Environm Studies, Ctr Excellence Environm Forens, Upm Serdang 43400, Selangor, Malaysia
Zakaria, Mohamad Pauzi
[1
]
Yaziz, Mohamad Ismail
论文数: 0引用数: 0
h-index: 0
机构:
Univ Putra Malaysia, Fac Environm Studies, Ctr Excellence Environm Forens, Upm Serdang 43400, Selangor, MalaysiaUniv Putra Malaysia, Fac Environm Studies, Ctr Excellence Environm Forens, Upm Serdang 43400, Selangor, Malaysia
Yaziz, Mohamad Ismail
[1
]
Surif, Salmijah
论文数: 0引用数: 0
h-index: 0
机构:
Univ Kebangsaan Malaysia, Fac Sci & Technol, Sch Environm & Nat Resources Sci, Ukm Bangi 43600, Selangor, MalaysiaUniv Putra Malaysia, Fac Environm Studies, Ctr Excellence Environm Forens, Upm Serdang 43400, Selangor, Malaysia
Surif, Salmijah
[2
]
机构:
[1] Univ Putra Malaysia, Fac Environm Studies, Ctr Excellence Environm Forens, Upm Serdang 43400, Selangor, Malaysia
[2] Univ Kebangsaan Malaysia, Fac Sci & Technol, Sch Environm & Nat Resources Sci, Ukm Bangi 43600, Selangor, Malaysia
Pollutants such as human pharmaceuticals and synthetic hormones that are not covered by environmental legislation have increasingly become important emerging aquatic contaminants. This paper reports the development of a sensitive and selective multi-residue method for simultaneous determination and quantification of 23 pharmaceuticals and synthetic hormones from different therapeutic classes in water samples. Target pharmaceuticals include anti-diabetic, antihypertensive, hypolipidemic agents, beta 2-adrenergic receptor agonist, antihistamine, analgesic and sex hormones. The developed method is based on solid phase extraction (SPE) followed by instrumental analysis using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) with 30 min total run time. River water samples (150 mL) and (sewage treatment plant) STP effluents (100 mL) adjusted to pH 2, were loaded into MCX (3 cm(3), 60 mg) cartridge and eluted with four different reagents for maximum recovery. Quantification was achieved by using eight isotopically labeled internal standards (IS.) that effectively correct for losses during sample preparation and matrix effects during LC-ESI-MS/MS analysis. Good recoveries higher than 70% were obtained for most of target analytes in all matrices. Method detection limit (MDL) ranged from 0.2 to 281 ng/L. The developed method was applied to determine the levels of target analytes in various samples, including river water and STP effluents. Among the tested emerging pollutants, chlorothiazide was found at the highest level, with concentrations reaching up to 865 ng/L in STP effluent, and 182 ng/L in river water. (c) 2010 Elsevier B.V. All rights reserved.