Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: Comparison with arthroscopy in 130 patients

被引:291
作者
Bredella, MA
Tirman, PFJ
Peterfy, CG
Zarlingo, M
Feller, JF
Bost, FW
Belzer, JP
Wischer, TK
Genant, HK
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] San Francisco Magnet Resonance Ctr, San Francisco, CA 94118 USA
[3] Desert Med Imaging Ctr, Indian Wells, CA 92210 USA
[4] Calif Pacific Orthoped & Sports Med, San Francisco, CA 94118 USA
关键词
D O I
10.2214/ajr.172.4.10587150
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to assess the accuracy of routine T2-weighted MR imaging in detecting and grading articular cartilage lesions in the knee compared with arthroscopy. SUBJECTS AND METHODS. We examined 130 consecutive patients who underwent MR imaging and arthroscopy of the knee for suspected internal derangement. MR imaging consisted of axial and coronal T2-weighted fast spin-echo sequences with fat saturation and sagittal T2-weighted spin-echo sequences. Each single plane was evaluated and graded for the presence and appearance of articular cartilage defects using a standard arthroscopic grading scheme adapted to MR imaging. RESULTS. Of the 86 arthroscopically proven abnormalities, 81 were detected on MR imaging. Sensitivity of the T2-weighted fast spin-echo sequence with fat saturation was 61% for the coronal plane alone and 59% for the axial plane alone. Specificity for each plane was 99%. Sensitivity for the sagittal T2-weighted spin-echo sequence was 40%, and specificity was 100%. Sensitivity of the combination of axial and coronal T2-weighted fast spin-echo sequences with fat saturation and sagittal T2-weighted spin-echo sequence compared with arthroscopy for revealing cartilage lesions was 94%, specificity was 99%, and accuracy was 98%. Sensitivity of coronal and axial T2-weighted fast spin-echo sequences with fat saturation was 93%, and specificity was 99%. Fifty-five lesions (64%) were identically graded on MR imaging and arthroscopy. Seventy-eight lesions (90%) were within one grade using MR imaging and arthroscopy, and 84 lesions (97%) were within two grades using MR imaging and arthroscopy. CONCLUSION. T2-weighted fast spin-echo MR imaging with fat saturation is an accurate and fast technique for detecting and grading articular cartilage defects in the knee. The combination of the axial and coronal planes offers sufficient coverage of articular surfaces to provide a high sensitivity and specificity for chondral defects.
引用
收藏
页码:1073 / 1080
页数:8
相关论文
共 28 条
  • [1] TREATMENT OF DEEP CARTILAGE DEFECTS IN THE KNEE WITH AUTOLOGOUS CHONDROCYTE TRANSPLANTATION
    BRITTBERG, M
    LINDAHL, A
    NILSSON, A
    OHLSSON, C
    ISAKSSON, O
    PETERSON, L
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (14) : 889 - 895
  • [2] SEVERITY OF ARTICULAR-CARTILAGE ABNORMALITY IN PATIENTS WITH OSTEOARTHRITIS - EVALUATION WITH FAST SPIN-ECHO MR VS ARTHROSCOPY
    BRODERICK, LS
    TURNER, DA
    RENFREW, DL
    SCHNITZER, TJ
    HUFF, JP
    HARRIS, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 99 - 103
  • [3] KNEE HYALINE CARTILAGE EVALUATED WITH MR IMAGING - A CADAVERIC STUDY INVOLVING MULTIPLE IMAGING SEQUENCES AND INTRAARTICULAR INJECTION OF GADOLINIUM AND SALINE SOLUTION
    CHANDNANI, VP
    HO, C
    CHU, P
    TRUDELL, D
    RESNICK, D
    [J]. RADIOLOGY, 1991, 178 (02) : 557 - 561
  • [4] Cartilage injuries: A review of 31,516 knee arthroscopies
    Curl, WW
    Krome, J
    Gordon, ES
    Rushing, J
    Smith, BP
    Poehling, GG
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1997, 13 (04) : 456 - 460
  • [5] DETECTION OF KNEE HYALINE CARTILAGE DEFECTS USING FAT-SUPPRESSED 3-DIMENSIONAL SPOILED GRADIENT-ECHO MR-IMAGING - COMPARISON WITH STANDARD MR-IMAGING AND CORRELATION WITH ARTHROSCOPY
    DISLER, DG
    MCCAULEY, TR
    WIRTH, CR
    FUCHS, MD
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) : 377 - 382
  • [6] Fat-suppressed three-dimensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee: Comparison with standard MR imaging and arthroscopy
    Disler, DG
    McCauley, TR
    Kelman, CG
    Fuchs, MD
    Ratner, LM
    Wirth, CR
    Hospodar, PP
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) : 127 - 132
  • [7] INTRAARTICULAR DIFFUSION OF GD-DOTA AFTER INTRAVENOUS-INJECTION IN THE KNEE - MR-IMAGING EVALUATION
    DRAPE, JL
    THELEN, P
    GAYDEPASSIER, P
    SILBERMANN, O
    BENACERRAF, R
    [J]. RADIOLOGY, 1993, 188 (01) : 227 - 234
  • [8] ARTICULAR-CARTILAGE DEFECTS - DETECTABILITY IN CADAVER KNEES WITH MR
    GYLYSMORIN, VM
    HAJEK, PC
    SARTORIS, DJ
    RESNICK, D
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (06) : 1153 - 1157
  • [9] PATELLAR CARTILAGE LESIONS - INVITRO DETECTION AND STAGING WITH MR IMAGING AND PATHOLOGICAL CORRELATION
    HAYES, CW
    SAWYER, RW
    CONWAY, WF
    [J]. RADIOLOGY, 1990, 176 (02) : 479 - 483
  • [10] EVALUATION OF ARTICULAR-CARTILAGE - RADIOGRAPHIC AND CROSS-SECTIONAL IMAGING TECHNIQUES
    HAYES, CW
    CONWAY, WF