The accuracy of ultrasound, stereotactic, and clinical core biopsies in the diagnosis of breast cancer, with an analysis of false-negative cases

被引:89
作者
Dillon, MF
Hill, ADK
Quinn, CM
O'Doherty, A
McDermott, EW
O'Higgins, N
机构
[1] St Vincents Univ Hosp, Dept Surg, Dublin 4, Ireland
[2] St Vincents Univ Hosp, Dept Pathol, Dublin 4, Ireland
[3] St Vincents Univ Hosp, Dept Radiol, Dublin 4, Ireland
[4] Univ Coll Dublin, Inst Biomol & Biomed Res, Dublin 2, Ireland
[5] BreastCheck, Natl Breast Screening Programme, Merion Unit, Dublin, Ireland
关键词
D O I
10.1097/01.sla.0000186186.05971.e0
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Preoperative core biopsy in breast cancer is becoming the standard of care. The aim of this study was to analyze the various methods of core biopsy with respect to diagnostic accuracy and to examine the management and outcome of those patients with false-negative biopsies. Methods: All patients undergoing core biopsy for breast abnormalities over a 5-year period (1999-2003) were reviewed. The accuracy rates for each method of core biopsy, the histologic agreement between the core pathology and subsequent excision pathology, and the length of follow-up for cases of benign disease were studied. Patients whose biopsies were benign but who were subsequently diagnosed with cancer underwent detailed review. Results: There were 2427 core biopsies performed over the 5-year period, resulting in a final diagnosis of cancer in 1384 patients, benign disease in 954 patients, and atypical disease in 89 patients. Biopsy type consisted of 1279 ultrasound-guided cores, 739 clinically guided cores, and 409 stereotactic-guided cores. The overall false-negative rate was 6.1%, with specific rates for ultrasound-, clinical-, and stereotactic-guided cores of 1.7%, 13%, and 8.9%, respectively. False-negative biopsies occurred in 85 patients, and in 8 of these patients the diagnosis was delayed by greater than 2 months. In all other false-negative cases, "triple assessment" review allowed prompt recognition of discordant biopsy results and further evaluation. Conclusion: Ultrasound guidance should be used to perform core biopsies in evaluating all breast abnormalities visible on ultrasound. Adherence to principles of triple assessment following biopsy allows for early recognition of the majority of false-negative cases.
引用
收藏
页码:701 / 707
页数:7
相关论文
共 43 条
  • [1] Core biopsy versus FNAC for palpable breast cancers. Is image guidance necessary?
    Agarwal, T
    Patel, B
    Rajan, P
    Cunningham, DA
    Darzi, A
    Hadjiminas, DJ
    [J]. EUROPEAN JOURNAL OF CANCER, 2003, 39 (01) : 52 - 56
  • [2] Ballo MS, 1996, CANCER, V78, P773
  • [3] BARRETO V, 1991, EUR J SURG ONCOL, V17, P237
  • [4] Percutaneous core biopsy of the breast: Effect of operator experience and number of samples on diagnostic accuracy
    Brenner, RJ
    Fajardo, L
    Fisher, PR
    Dershaw, DD
    Evans, WP
    Bassett, L
    Feig, S
    Mendelson, E
    Jackson, V
    Margolin, FR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (02) : 341 - 346
  • [5] Changing to core biopsy in an NHS breast screening unit
    Britton, PD
    Flower, CDR
    Freeman, AH
    Sinnatamby, R
    Warren, R
    Goddard, MJ
    Wight, DGD
    Bobrow, L
    [J]. CLINICAL RADIOLOGY, 1997, 52 (10) : 764 - 767
  • [6] Stereotactic core-needle breast biopsy by surgeons - Minimum 2-year follow-up of benign lesions
    Burns, RP
    Brown, JP
    Roe, SM
    Sprouse, LR
    Yancey, AE
    Witherspoon, LE
    [J]. ANNALS OF SURGERY, 2000, 232 (04) : 542 - 547
  • [7] Crowe JP, 2003, SURGERY, V134, P523, DOI 10.1016/S0039-6060(03)00269-1
  • [8] A prospective review of the decline of excisional breast biopsy
    Crowe, JP
    Rim, A
    Patrick, R
    Rybicki, L
    Grundfest, S
    Kim, J
    Lee, K
    Levy, L
    [J]. AMERICAN JOURNAL OF SURGERY, 2002, 184 (04) : 353 - 355
  • [9] CUSICK JD, 1990, SURG GYNECOL OBSTET, V170, P407
  • [10] Dennison G, 2003, Breast J, V9, P491, DOI 10.1046/j.1524-4741.2003.09611.x