Polyion sensors as liquid junction-free reference electrodes

被引:23
作者
Mi, YM [1 ]
Mathison, S [1 ]
Bakker, E [1 ]
机构
[1] Auburn Univ, Dept Chem, Auburn, AL 36849 USA
关键词
D O I
10.1149/1.1390782
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Potentiometric sensors for polyionic analytes may show very low electrode slopes, as predicted by the Nernst equation. This paper explores the possibility of using plasticized poly(vinyl chloride) membrane electrodes containing the ion-exchanger tridodecylmethylammonium chloride, conditioned in solutions of the sodium poly(anetholesulfonate), a polyanionic anticoagulant also called Liquoid(R), as reference electrodes without a liquid junction. This approach may be useful in samples such as whole blood that contain variable levels of a polyanionic anticoagulant. It is found that such electrodes show virtually no NaCl response in samples with and without anticoagulant and widely varying levels of NaCl. (C) 1999 The Electrochemical Society. S1099- 0062( 98) 10- 011- 6. All rights reserved.
引用
收藏
页码:198 / 200
页数:3
相关论文
共 12 条
[1]   SELECTIVITY OF POLYMER MEMBRANE-BASED ION-SELECTIVE ELECTRODES - SELF-CONSISTENT MODEL DESCRIBING THE POTENTIOMETRIC RESPONSE IN MIXED ION SOLUTIONS OF DIFFERENT CHARGE [J].
BAKKER, E ;
MERUVA, RK ;
PRETSCH, E ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (19) :3021-3030
[2]   Determination of improved selectivity coefficients of polymer membrane ion-selective electrodes by conditioning with a discriminated ion [J].
Bakker, E .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1996, 143 (04) :L83-L85
[3]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[4]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[5]   EXTRACTION THERMODYNAMICS OF POLYANIONS INTO PLASTICIZED POLYMER MEMBRANES DOPED WITH LIPOPHILIC ION-EXCHANGERS - A POTENTIOMETRIC STUDY [J].
FU, B ;
BAKKER, E ;
YANG, VC ;
MEYERHOFF, ME .
MACROMOLECULES, 1995, 28 (17) :5834-5840
[6]   RESPONSE MECHANISM OF POLYMER MEMBRANE-BASED POTENTIOMETRIC POLYION SENSORS [J].
FU, B ;
BAKKER, E ;
YUN, JH ;
YANG, VC ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (14) :2250-2259
[7]   Solvent-processible polymer membrane-based liquid junction-free reference electrode [J].
Lee, HJ ;
Hong, US ;
Lee, DK ;
Shin, JH ;
Nam, H ;
Cha, GS .
ANALYTICAL CHEMISTRY, 1998, 70 (16) :3377-3383
[8]   ELECTROCHEMICAL SENSOR FOR HEPARIN - FURTHER CHARACTERIZATION AND BIOANALYTICAL APPLICATIONS [J].
MA, SC ;
YANG, VC ;
FU, B ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1993, 65 (15) :2078-2084
[9]   HEPARIN-RESPONSIVE ELECTROCHEMICAL SENSOR - A PRELIMINARY-STUDY [J].
MA, SC ;
YANG, VC ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1992, 64 (06) :694-697