A new ultrasound contrast imaging approach based on the combination of multiple imaging pulses and a separate release burst

被引:47
作者
Frinking, PJA [1 ]
Céspedes, EI
Kirkhorn, J
Torp, HG
de Jong, N
机构
[1] Bracco Res SA, Geneva, Switzerland
[2] EndoSon Corp, Rancho Cordova, CA 95670 USA
[3] Norwegian Univ Sci & Technol, Dept Physiol & Biomed Engn, N-7034 Trondheim, Norway
[4] Erasmus Univ, Thoraxctr, Dept Cardiol & Expt Echocardiog, NL-3000 DR Rotterdam, Netherlands
[5] ICIN, Utrecht, Netherlands
关键词
D O I
10.1109/58.920687
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A new ultrasound contrast imaging technique is described that optimally employs the rupture of the contrast agent. It is based on a combination of multiple high frequency, broadband, imaging pulses and a separate release burst. The imaging pulses are used to survey the target before and after the rupture and release of free gas bubbles. In this way, both processes (imaging and release) can be optimized separately. The presence of the contrast agent is simply detected by correlating or subtracting the signal responses of the imaging pulses. Because the time delay between the imaging pulses can be very short, the subtraction is less affected by tissue motion and can be done in real time. In vitro measurements showed that by using a release burst, the detection sensitivity increased 12 to 43 dB for different types of contrast agents. In the presence of a moving phantom, the increase in sensitivity was 22 dB. This new method is very sensitive for contrast agent detection in fundamental imaging mode and, therefore, non-linear propagation effects do not limit the maximum obtainable agent-to-tissue ratio. However, because of the inherent destruction of the contrast agent, it has to operate in an intermittent way. Through experiments, we have demonstrated the potential of the method to achieve simultaneous high sensitivity for contrast detection, i.e., high agent-to-tissue ratio, and high spatial resolution performance for different types of contrast agents.
引用
收藏
页码:643 / 651
页数:9
相关论文
共 22 条
[1]   Preliminary study in differential contrast echography [J].
Arditi, M ;
Brenier, T ;
Schneider, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (08) :1185-1194
[2]   ULTRASOUND MOVING TARGET INDICATOR SYSTEM FOR DIAGNOSTIC USE [J].
BARNES, RW ;
THURSTONE, FL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1971, BM18 (01) :4-+
[3]   A NOVEL METHOD FOR ANGLE INDEPENDENT ULTRASONIC-IMAGING OF BLOOD-FLOW AND TISSUE MOTION [J].
BOHS, LN ;
TRAHEY, GE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (03) :280-286
[4]   BACKGROUND SUBTRACTION FROM TIME-INTENSITY CURVES IN VIDEODENSITOMETRY - A PITFALL IN FLOW ASSESSMENT USING CONTRAST ECHOCARDIOGRAPHY [J].
BOS, LJ ;
PIEK, JJ ;
SPAAN, JAE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (09) :1211-1218
[5]  
BURNS PN, 1992, RADIOLOGY, V185, P142
[6]  
CATE FJT, 1992, IMAGING, V4, P241
[7]   Scattering properties of encapsulated gas bubbles at high ultrasound pressures [J].
Frinking, PJA ;
de Jong, N ;
Céspedes, EI .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 105 (03) :1989-1996
[8]   Acoustic modeling of shell-encapsulated gas bubbles [J].
Frinking, PJA ;
de Jong, N .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (04) :523-533
[9]  
FRINKING PJA, 1997, IEEE ULTR S TOR ON C
[10]   CURRENT TIME-DOMAIN METHODS FOR ASSESSING TISSUE MOTION BY ANALYSIS FROM REFLECTED ULTRASOUND ECHOES - A REVIEW [J].
HEIN, IA ;
OBRIEN, WD .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (02) :84-102