摘要
Stereotactic localization of an intracranial lesion by computed tomography or magnetic resonance imaging requires the use of a head frame that is fixed to the skull of the patient. To such head frames are attached either N-shaped or V-shaped localization rods. Because of patient positioning, the transverse imaging slices may not be parallel to the frame base; a coordinate transformation algorithm that takes this possibility into consideration is crucial. Here we propose such an algorithm for a head frame with V-shaped localization rods. Our algorithm determines the transformation matrix between the image coordinate system of a transverse image and the frame coordinate system. The determining procedure has three steps: (a) calculation of the oblique angles of a transverse image relative to the head frame and calculation of the image magnification factor; (b) determination of the coordinates of four central markers in both coordinate systems; and (c) determination of the 3 x 3 transformation matrix by using the coordinates of the four markers. This algorithm is robust in principle and is useful for improving the accuracy of localization.
引用
收藏
页码:N1 / N7
页数:7
相关论文
共 11 条
[1]   STEREOTAXIC FRAME AND COMPUTER SOFTWARE FOR CT-DIRECTED NEUROSURGICAL LOCALIZATION [J].
BROWN, RA ;
ROBERTS, TS ;
OSBORN, AG .
INVESTIGATIVE RADIOLOGY, 1980, 15 (04) :308-312
[2]   TARGET POINT CALCULATION IN THE COMPUTERIZED-TOMOGRAPHY - COMPARISON OF DIFFERENT STEREOTAXIC METHODS [J].
GRUNERT, P ;
MAURER, J .
NEUROSURGICAL REVIEW, 1995, 18 (01) :15-24
[3]   CEREBRAL RADIATION SURGERY USING MOVING FIELD IRRADIATION AT A LINEAR-ACCELERATOR FACILITY [J].
HARTMANN, GH ;
SCHLEGEL, W ;
STURM, V ;
KOBER, B ;
PASTYR, O ;
LORENZ, WJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (06) :1185-1192
[4]   PRECISION AND ACCURACY OF STEREOTAXIC CONVERGENT-BEAM IRRADIATIONS FROM A LINEAR-ACCELERATOR [J].
HARTMANN, GH ;
BAUERKIRPES, B ;
SERAGO, CF ;
LORENZ, WJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (02) :481-492
[5]   STEREOTACTIC RADIOSURGERY [J].
LEKSELL, L .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1983, 46 (09) :797-803
[6]   A SYSTEM FOR STEREOTACTIC RADIOSURGERY WITH A LINEAR-ACCELERATOR [J].
LUTZ, W ;
WINSTON, KR ;
MALEKI, N .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (02) :373-381
[7]   COORDINATE TRANSFORMATIONS AND CALCULATION OF THE ANGULAR AND DEPTH PARAMETERS FOR A STEREOTAXIC SYSTEM [J].
SAW, CB ;
AYYANGAR, K ;
SUNTHARALINGAM, N .
MEDICAL PHYSICS, 1987, 14 (06) :1042-1044
[8]   STEREOTAXIC TARGET POINT VERIFICATION OF AN X-RAY AND CT LOCALIZER [J].
SERAGO, CF ;
LEWIN, AA ;
HOUDEK, PV ;
GONZALEZARIAS, S ;
HARTMANN, GH ;
ABITBOL, AA ;
SCHWADE, JG .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (03) :517-523
[9]   STEREOTAXIC LOCALIZATION OF INTRACRANIAL TARGETS [J].
SIDDON, RL ;
BARTH, NH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (08) :1241-1246
[10]  
STANEK G, 1996, STANDARD MATH TABLES, P681