Early features of apoptosis detected by four different flow cytometry assays

被引:92
作者
Overbeeke, R
Steffens-Nakken, H
Vermes, I
Reutelingsperger, C
Haanen, C
机构
[1] Med Spectrum Twente, Dept Clin Chem, Hosp Grp, NL-7500 KA Enschede, Netherlands
[2] Univ Maastricht, Dept Biochem, Maastricht, Netherlands
关键词
7A6-antigen; Annexin V; apoptosis; DNA fragmentation; phosphatidyl serine;
D O I
10.1023/A:1009649025439
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The objective of this study was to investigate the sensitivity, specificity and reproducibility of some frequently used apoptosis assays. The degree of apoptosis was tested in two T-lymphoblastoid cell lines, HSB and Jurkat, in which apoptosis was induced by ionizing radiation. HSB and Jurkat samples were taken before, and 0, 2, 4, 6, 8 and 24 h after irradiation with 6 and 10 Gray, or with 10 and 14 Gray, respectively. Four frequently used flow cytometric techniques were evaluated: (i) Annexin V/Propidium lodide assay, detecting the translocation of phosphatidylserine to the outer leaflet of the plasma membrane, simultaneously with preservation of the membrane integrity; (ii) Terminal deoxynucleotidyl Transferase (TdT) Uridine triphosphate (UTP) nick end labelling (TUNEL), revealing the presence of DNA strand breaks; (iii) DNA-flow cytometry, measuring DNA-stainability (DNA-fragmentation assay) and (iv) Phycoerythrin-labelled (PE) Apo2.7-assay, a monoclonal antibody against 7A6 antigen, a protein, which becomes exposed upon the mitochondrial membrane during apoptosis, As a general standard for identifying that apoptosis had occurred, the cells were assessed for the presence of DNA-laddering on agar gel electrophoresis and by demonstration of characteristic cell morphology, Results were as follows: Fluorescein Isothiocyanate (FITC)-labelled Annexin V/Propidium iodide flow cytometry appeared to be the most sensitive, the most specific and the most user-friendly test for measurement of apoptosis of cells in culture conditions in suspension. The expression of 7A6 antigen on the mitochondrial membrane appeared to be not specific for apoptotic cell death.
引用
收藏
页码:115 / 121
页数:7
相关论文
共 10 条
[1]   IDENTIFICATION OF PROGRAMMED CELL-DEATH INSITU VIA SPECIFIC LABELING OF NUCLEAR-DNA FRAGMENTATION [J].
GAVRIELI, Y ;
SHERMAN, Y ;
BENSASSON, SA .
JOURNAL OF CELL BIOLOGY, 1992, 119 (03) :493-501
[2]  
GORCZYCA W, 1992, INT J ONCOL, V1, P639
[3]   ANNEXIN-V FOR FLOW CYTOMETRIC DETECTION OF PHOSPHATIDYLSERINE EXPRESSION ON B-CELLS UNDERGOING APOPTOSIS [J].
KOOPMAN, G ;
REUTELINGSPERGER, CPM ;
KUIJTEN, GAM ;
KEEHNEN, RMJ ;
PALS, ST ;
VANOERS, MHJ .
BLOOD, 1994, 84 (05) :1415-1420
[4]   EARLY REDISTRIBUTION OF PLASMA-MEMBRANE PHOSPHATIDYLSERINE IS A GENERAL FEATURE OF APOPTOSIS REGARDLESS OF THE INITIATING STIMULUS - INHIBITION BY OVEREXPRESSION OF BCL-2 AND ABL [J].
MARTIN, SJ ;
REUTELINGSPERGER, CPM ;
MCGAHON, AJ ;
RADER, JA ;
VANSCHIE, RCAA ;
LAFACE, DM ;
GREEN, DR .
JOURNAL OF EXPERIMENTAL MEDICINE, 1995, 182 (05) :1545-1556
[5]   PROGRAMMED DEATH OF T-CELLS IN HIV-1 INFECTION [J].
MEYAARD, L ;
OTTO, SA ;
JONKER, RR ;
MIJNSTER, MJ ;
KEET, RPM ;
MIEDEMA, F .
SCIENCE, 1992, 257 (5067) :217-219
[6]   A SIMPLE SALTING OUT PROCEDURE FOR EXTRACTING DNA FROM HUMAN NUCLEATED CELLS [J].
MILLER, SA ;
DYKES, DD ;
POLESKY, HF .
NUCLEIC ACIDS RESEARCH, 1988, 16 (03) :1215-1215
[7]   A RAPID AND SIMPLE METHOD FOR MEASURING THYMOCYTE APOPTOSIS BY PROPIDIUM IODIDE STAINING AND FLOW-CYTOMETRY [J].
NICOLETTI, I ;
MIGLIORATI, G ;
PAGLIACCI, MC ;
GRIGNANI, F ;
RICCARDI, C .
JOURNAL OF IMMUNOLOGICAL METHODS, 1991, 139 (02) :271-279
[8]   A NOVEL ASSAY FOR APOPTOSIS - FLOW CYTOMETRIC DETECTION OF PHOSPHATIDYLSERINE EXPRESSION ON EARLY APOPTOTIC CELLS USING FLUORESCEIN-LABELED ANNEXIN-V [J].
VERMES, I ;
HAANEN, C ;
STEFFENSNAKKEN, H ;
REUTELINGSPERGER, C .
JOURNAL OF IMMUNOLOGICAL METHODS, 1995, 184 (01) :39-51
[9]  
Wolfe James T., 1996, P51
[10]  
Zhang CH, 1996, J IMMUNOL, V157, P3980