Continuous assessment of multiple vital physiological functions in conscious freely moving rats using telemetry and a plethysmography system

被引:27
作者
Schierok, H [1 ]
Markert, M [1 ]
Pairet, M [1 ]
Guth, B [1 ]
机构
[1] Boehringer Ingelheim KG, Pharma, Dept Pulm Res, Gen Pharmacol Grp, D-88397 Biberach, Germany
关键词
telemetry; plethysmography; conscious rats; safety pharmacology;
D O I
10.1016/S1056-8719(00)00101-5
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The general pharmacologist in the pharmaceutical industry is challenged to generate physiologically relevant data on possible safety liabilities or on secondary therapeutic uses as early as possible in drug development. This implies the need for efficient use of usually only small supplies of test article. For this reason, we have developed a new animal model combining various elements to provide a broad spectrum of data focussing on the so-called vital physiological functions: cardiovascular, respiratory, and central nervous system. This system uses rats chronically implanted with transmitters for the measurement of arterial pressure, EGG, and body temperature. Modification of the transmitters also allows for the simultaneous assessment of locomotor activity. Studies are performed with these rats in plethysmographs placed directly over the antenna units thus allowing for the additional assessment of respiratory function in the same studies. Using this system, we can generate simultaneously a wide range of relevant physiological parameters in conscious rats with a modest requirement for test article. Such an approach is highly useful for getting early safety readouts of potential drug development candidates as well as for detecting possible secondary therapeutic actions of a drug. (C) 2001 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:211 / 217
页数:7
相关论文
共 9 条
[1]   Radiotelemetric versus externalized catheter monitoring of blood pressure: Effect of vasopressin in spontaneous hypertension [J].
Balakrishnan, S ;
Tatchum-Talom, R ;
McNeill, JR .
JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 1998, 40 (02) :87-93
[2]   Measurement of bronchoconstriction using whole-body plethysmograph: Comparison of freely moving versus restrained guinea pigs [J].
Chong, BTY ;
Agrawal, DK ;
Romero, FA ;
Townley, RG .
JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 1998, 39 (03) :163-168
[3]  
Detweiler DK., 1997, COMPREHENSIVE TOXICO, P95
[4]   A pharmacological validation of radiotelemetry in conscious, freely moving rats [J].
Deveney, AM ;
Kjellström, Å ;
Forsberg, T ;
Jackson, DM .
JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 1998, 40 (02) :71-79
[5]  
*ICH S7, 1999, ICH TOP S7 GUID SAF
[6]   COMPREHENSIVE OBSERVATIONAL ASSESSMENT .IA. A SYSTEMATIC QUANTITATIVE PROCEDURE FOR ASSESSING BEHAVIORAL AND PHYSIOLOGIC STATE OF MOUSE [J].
IRWIN, S .
PSYCHOPHARMACOLOGIA, 1968, 13 (03) :222-&
[7]   APPLICATION OF RADIO TELEMETRY TO CARDIOVASCULAR MONITORING IN UNRESTRAINED ANIMALS [J].
MELLOR, PM ;
PETTINGER, SJ .
JOURNAL OF PHARMACOLOGICAL METHODS, 1986, 16 (02) :181-184
[8]  
Pairet M, 1997, DRUG DEVELOP RES, V42, P57, DOI 10.1002/(SICI)1098-2299(199710)42:2<57::AID-DDR1>3.0.CO
[9]  
2-O