Activating piezoelectric crystal surface by silanization for microgravimetric immunobiosensor application

被引:48
作者
Suri, CR
Mishra, GC
机构
[1] Institute of Microbial Technology, Sector 39-A
关键词
3-aminopropyltriethoxysilane; fluorescence isothiocyanate; immunobiosensor; protein G; immunoglobulin G;
D O I
10.1016/0956-5663(96)88084-5
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The development of a microgravimetric immunobiosensor using a piezoelectric quartz crystal as a detector requires a stable and reproducible immobilization method for ligand binding. The method of silanization using 3-aminopropyltriethoxysilane (APTES) has been widely used for activating the carrier surface. In the present study, APTES deposition on a piezoelectric crystal surface was studied under various solvent conditions. A fluorescence method, using fluorescence isothiocyanate as a dye, was demonstrated for the quantification of amino groups on the silanized piezoelectric crystal surface. The optimum binding conditions of APTES deposition on a piezoelectric crystal surface were incorporated for the covalent immobilization of protein on the crystal surface in developing a stable and sensitive microgravimetric immunobiosensor. Determination of immunoglobulin G (IgG) concentration was performed using APTES modified piezoelectric crystals coated with protein G. The resonant frequency shift, resulting from the formation of protein G-IgG complex on the crystal surface, correlated with the concentration of IgG in the range 10 ng/ml to 0.1 mg/ml. The APTES modified, protein G coated crystals were found to be quite stable and did not show a significant loss of sensitivity even after 12 weeks of storage at 4 degrees C in a desiccator. (C) 1996 Published by Elsevier Science Limited
引用
收藏
页码:1199 / 1205
页数:7
相关论文
共 19 条
  • [1] AKERSTROM B, 1985, J IMMUNOL, V135, P2589
  • [2] AKERSTROM B, 1986, J BIOL CHEM, V261, P240
  • [3] A CONCANAVALIN A-COATED PIEZOELECTRIC CRYSTAL BIOSENSOR
    BARNES, C
    DSILVA, C
    JONES, JP
    LEWIS, TJ
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1991, 3 (04) : 295 - 304
  • [4] CARVAJAL GS, 1988, ANAL CHEM, V60, P1776
  • [5] DAWSON RM, 1986, DATA BIOCH RES, P466
  • [6] IMMOBILIZATION METHODS FOR PIEZOELECTRIC BIOSENSORS
    GUILBAULT, GG
    LUONG, JHT
    PRUSAKSOCHACZEWSKI, E
    [J]. BIO-TECHNOLOGY, 1989, 7 (04): : 349 - 351
  • [7] JIMBO Y, 1990, BIOINSTRUMENTATION R, P466
  • [8] X-RAY PHOTOELECTRON-SPECTROSCOPY OF SILICA SURFACES TREATED WITH POLYFUNCTIONAL SILANES
    KALLURY, KMR
    KRULL, UJ
    THOMPSON, M
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (02) : 169 - 172
  • [9] LACASCIOBROWN L, 1990, ANAL CHIM ACTA, V228, P107
  • [10] LASKY S, 1989, CHEM SENSORS MICROIN, P403