摘要
Three-dimensional (3D) MR imaging of the knee is useful to detect cartilage abnormalities, although the tissue contrast in 3D gradient-recalled echo (GRE) sequences such as gradient-recalled acquisition in the steady state (GRASS) or fast low-angle shot (FLASH) is poor. T2 contrast can be added to a GRASS sequence by combining the signals from the first and second gradient echoes, which form immediately after and immediately before each radiofrequency (RF) pulse in a 3D GRE sequence, We have optimized a 3D dual echo in the steady state (DESS) sequence, which produces one averaged image from the two echoes, for use in the detection of articular cartilage abnormalities, In the optimization process, we examined the imaging parameters of flip angle (alpha), repetition time (TR), echo time (TE), and bandwidth to maximize the contrast between cartilage and joint fluid, A theoretical simulation of the sequence was; confirmed with experiments conducted on phantoms with known T1 and T2. On the basis of theoretical predictions and experiments using healthy volunteers, we determined that an optimized sequence with a bandwidth of 98 Hz per pixel, a TR of 30 msec, a TE of 7.1 msec, and an alpha of 60 degrees produced the highest contrast between cartilage and fluid within a defined acquisition time of 6 minutes, Additional contrast was obtained by filtering the second-echo image to eliminate noise before adding it to the first-echo image.
引用
收藏
页码:329 / 335
页数:7
相关论文
共 16 条
[1]
ADAMS ME, 1991, J RHEUMATOL, V18, P1573
[2]
A NEW STEADY-STATE IMAGING SEQUENCE FOR SIMULTANEOUS ACQUISITION OF 2-MR IMAGES WITH CLEARLY DIFFERENT CONTRASTS [J].
BRUDER, H ;
FISCHER, H ;
GRAUMANN, R ;
DEIMLING, M .
MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (01) :35-42
[3]
IMPLEMENTATION AND OPTIMIZATION BY THE SIMPLEX-METHOD OF A 3D DOUBLE ECHO SEQUENCE IN STEADY-STATE FREE PRECESSION [J].
DUFOUR, I ;
BITTOUN, J ;
IDYPERETTI, I ;
JOLIVET, O ;
DARRASSE, L ;
DIPAOLA, R .
MAGNETIC RESONANCE IMAGING, 1993, 11 (01) :87-93
[4]
ENGEL A, 1993, EUR RADIOL, V3, P161
[5]
ARTICULAR-CARTILAGE DEFECTS - DETECTABILITY IN CADAVER KNEES WITH MR [J].
GYLYSMORIN, VM ;
HAJEK, PC ;
SARTORIS, DJ ;
RESNICK, D .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (06) :1153-1157
[6]
HARDY PA, 1984, MED PHYS, V12, P581
[7]
KONIG H, 1987, RADIOLOGY, V164, P753
[8]
FAST SSFP GRADIENT ECHO SEQUENCE FOR SIMULTANEOUS ACQUISITIONS OF FID AND ECHO SIGNALS [J].
LEE, SY ;
CHO, ZH .
MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (02) :142-150
[9]
LEVENBERGMARQUA, NUMERICAL RECIPES
[10]
MR-IMAGING OF THE ARTHRITIC KNEE - IMPROVED DISCRIMINATION OF CARTILAGE, SYNOVIUM, AND EFFUSION WITH PULSED SATURATION-TRANSFER AND FAT-SUPPRESSED T1-WEIGHTED SEQUENCES [J].
PETERFY, CG ;
MAJUMDAR, S ;
LANG, P ;
VANDIJKE, CF ;
SACK, K ;
GENANT, HK .
RADIOLOGY, 1994, 191 (02) :413-419