Aperture modulated arc therapy

被引:62
作者
Crooks, SM
Wu, XD
Takita, C
Watzich, M
Xing, L
机构
[1] Sylvester Comprehens Canc Ctr, Dept Radiat Oncol, Miami, FL 33136 USA
[2] Stanford Univ, Med Ctr, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
D O I
10.1088/0031-9155/48/10/307
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We show that it is possible to translate an intensity modulated radiation therapy (IMRT) treatment plan and deliver it as a single arc. This technique is referred to in this paper as aperture modulation arc therapy (AMAT). During this arc, the MLC leaves do not conform to the projection of the target PTV and the machine output of the accelerator has a constant value. Dose was calculated using the CORVUS 4.0 IMRT system, which uses a pencil beam dose algorithm, and treatments were delivered using a Varian 2100C/D Clinac. Results are presented for a head and neck and a prostate case, showing the equivalence of the IMRT and the translated AMAT delivery. For a prostate AMAT delivery, coronal plane film dose for the IMRT and AMAT deliveries agreed within 7.19 +/- 6.62%. For a meningioma the coronal plane dose distributions were similar to a value of 4.6 +/- 6.62%. Dose to the isocentre was measured as being within 2% of the planned value in both cases.
引用
收藏
页码:1333 / 1344
页数:12
相关论文
共 12 条
[1]  
CROOKS SM, 2002, PHYS MED BIOL, V47, P1
[2]  
HO A, 2002, 44 AAPM ANN M MONTR
[3]   DYNAMIC FIELD SHAPING TO OPTIMIZE STEREOTAXIC RADIOSURGERY [J].
LEAVITT, DD ;
GIBBS, FA ;
HEILBRUN, MP ;
MOELLER, JH ;
TAKACH, GA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (05) :1247-1255
[4]   TOMOTHERAPY - A NEW CONCEPT FOR THE DELIVERY OF DYNAMIC CONFORMAL RADIOTHERAPY [J].
MACKIE, TR ;
HOLMES, T ;
SWERDLOFF, S ;
RECKWERDT, P ;
DEASY, JO ;
YANG, J ;
PALIWAL, B ;
KINSELLA, T .
MEDICAL PHYSICS, 1993, 20 (06) :1709-1719
[5]  
NAKAIDZUMI M, 1938, STRAHLENTHERAPIE, V59, P168
[6]  
TAKAHASHI S, 1961, Strahlentherapie, V115, P478
[7]   Intensity modulated radiation therapy (IMRT) following prostatectomy: More favorable acute genitourinary toxicity profile compared to primary IMRT for prostate cancer [J].
Teh, BS ;
Mai, WY ;
Augspurger, ME ;
Uhl, BM ;
McGary, J ;
Dong, L ;
Grant, WH ;
Butler, EB ;
Lu, HH ;
Woo, SY ;
Carpenter, LS ;
Chiu, JK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (02) :465-472
[8]  
WACHSMANN F, 1962, MOVING FIELD RAD THE
[9]  
WU X, 2002, 44 AAPM ANN M MONTR
[10]   Optimization of importance factors in inverse planning [J].
Xing, L ;
Li, JG ;
Donaldson, S ;
Le, QT ;
Boyer, AL .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (10) :2525-2536