Noninvasive evaluation of hand circulation before radial artery harvest for coronary artery bypass grafting

被引:68
作者
Starnes, SL
Wolk, SW
Lampman, RM
Shanley, CJ
Prager, RL
Kong, BK
Fowler, JJ
Page, JM
Babcock, SL
Lange, LA
Erlandson, EE
Whitehouse, WM
机构
[1] St Joseph Mercy Hosp, Michigan Heart & Vasc Inst, Ann Arbor, MI 48104 USA
[2] St Joseph Mercy Hosp, Dept Surg, Vasc Surg Sect, Ann Arbor, MI 48104 USA
[3] St Joseph Mercy Hosp, Dept Surg, Sect Cardiac Surg, Ann Arbor, MI 48104 USA
[4] St Joseph Mercy Hosp, Dept Surg, Dept Thorac Surg, Ann Arbor, MI 48104 USA
关键词
D O I
10.1016/S0022-5223(99)70421-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Radial artery harvesting for coronary artery bypass may lead to digit ischemia if collateral hand circulation is inadequate. The modified Alien's test is the most common preoperative screening test used. Unfortunately, this test has high false-positive and false-negative rates. The purpose of this study was to compare the results of a modified Alien's test with digit pressure change during radial artery compression for assessing collateral circulation before radial artery harvest. Methods: One hundred twenty-nine consecutive patients were studied before coronary artery bypass operations. A modified Alien's test was performed with Doppler ultrasound to assess blood flow in the superficial palmar arch before and during radial artery compression. A decreased audible Doppler signal after radial artery compression was considered a positive modified Alien's test. First and second digit pressures were measured before and during radial artery compression. A decrease in digit pressure of 40 mm Hg or more (digit Delta P) with radial artery compression was considered positive. Results: Seven of 14 dominant extremities (50%) and 8 of the 16 nondominant extremities (50%) with a positive modified Alien's test had a digit Delta P of less than 40 mm Hg (false positive). Sixteen of 115 dominant extremities (14%) and 5 of 112 nondominant extremities (4%) with a negative Alien's test had a digit Delta P of 40 mm Hg or more with radial artery compression (false negative). Conclusion: Use of the modified Alien's test for screening before radial artery harvest may unnecessarily exclude some patients from use of this conduit and may also place a number of patients at risk for digit ischemia from such harvest. Direct digit pressure measurement is a simple, objective method that may more precisely select patients for radial artery harvest. Additional studies are needed to define objective digital pressure criteria that will accurately predict patients at risk for hand ischemia after radial harvest.
引用
收藏
页码:261 / 265
页数:5
相关论文
共 13 条
[1]  
BAKER RJ, 1976, SURGERY, V80, P449
[2]   RADIAL ARTERY AND INFERIOR EPIGASTRIC ARTERY IN COMPOSITE GRAFTS - IMPROVED MIDTERM ANGIOGRAPHIC RESULTS [J].
CALAFIORE, AM ;
DIGIAMMARCO, G ;
TEODORI, G ;
DANNUNZIO, E ;
VITOLLA, G ;
FINO, C ;
MADDESTRA, N .
ANNALS OF THORACIC SURGERY, 1995, 60 (03) :517-524
[3]  
Carpentier A, 1973, Ann Thorac Surg, V16, P111
[4]  
COLEMAN S, 1961, SURG GYNECOL OBSTET, V113, P406
[5]  
DIETL CA, 1995, ANN THORAC SURG, V60, P102
[6]   THE TECHNIQUE OF RADIAL ARTERY BYPASS-GRAFTING AND EARLY CLINICAL-RESULTS [J].
FREMES, SE ;
CHRISTAKIS, GT ;
DELRIZZO, DF ;
MUSIANI, A ;
MALLIDI, H ;
GOLDMAN, BS .
JOURNAL OF CARDIAC SURGERY, 1995, 10 (05) :537-544
[7]   A MODIFICATION OF ALLEN TEST TO DETECT ABERRANT ULNAR COLLATERAL CIRCULATION [J].
GANDHI, SK ;
REYNOLDS, AC .
ANESTHESIOLOGY, 1983, 59 (02) :147-148
[8]   ALLEN TEST AND SYSTOLIC ARTERIAL-PRESSURE IN THE THUMB [J].
HUSUM, B ;
BERTHELSEN, P .
BRITISH JOURNAL OF ANAESTHESIA, 1981, 53 (06) :635-637
[9]   ACUTE-ISCHEMIA OF THE HAND RESULTING FROM ELEVATION OF A RADIAL FOREARM FLAP [J].
JONES, BM ;
OBRIEN, CJ .
BRITISH JOURNAL OF PLASTIC SURGERY, 1985, 38 (03) :396-397
[10]  
KAMIENSKI RW, 1976, SURG GYNECOL OBSTET, V142, P861