Fracture resistance of short, randomly oriented, glass fiber-reinforced composite premolar crowns

被引:40
作者
Garoushi, Sufyan [1 ]
Vallittu, Pekka K. [1 ]
Lassila, Lippo V. J. [1 ]
机构
[1] Univ Turku, Inst Dent, Dept Prosthet Dent & Biomat Sci, FI-20520 Turku, Finland
关键词
fiber-reinforced composite; FRC; load-bearing capacity; fiber composite; crown restorations;
D O I
10.1016/j.actbio.2007.02.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The aim of this work was to determine the static load-bearing capacity of posterior composite crowns made of experimental composite resin (FC) with short fiber fillers and a semi-interpenetrating polymer network (IPN) matrix. In addition, we wanted to investigate how load-bearing capacity of surface composite resins was affected by substructures of fiber-reinforced composite (FRC) and FC, and by different curing systems. Five groups of crowns were fabricated (n = 6). The crowns were either polymerized with a hand-light curing unit (LCU) or cured in a vacuum curing device (VLC) before they were statically loaded at a speed of 1 mm min(-1) until fracture. Failure modes were visually examined. Data were analyzed using ANOVA. ANOVA revealed that crowns made from the FC had a statistically significant higher load-bearing capacity than the control PFC composite. Crowns with FRC substructure and PFC covering gave force values of 348 N (LCU) and 1199 N (VLC), respectively, which were lower than the values of FC composite. No statistically significant difference was found between crowns made from plain FC composite and those made from FC composite with a surface layer of PFC (P = 0.892 and 1.00). Restorations made from short glass fiber-containing composite resin with IPN-polymer matrix showed better load bearing capacity than those made with either plain PFC or PFC reinforced with FRC substructure. (c) 2007 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:779 / 784
页数:6
相关论文
共 36 条
[1]
The combined effects of load, moisture and temperature on the properties of E-glass/epoxy composites [J].
Abdel-Magid, B ;
Ziaee, S ;
Gass, K ;
Schneider, M .
COMPOSITE STRUCTURES, 2005, 71 (3-4) :320-326
[2]
[Anonymous], ACAD DENT MAT T
[3]
ASMUSSEN E, 1982, SCAND J DENT RES, V90, P484
[4]
BAYNE SC, 1996, ACAD DENT MAT T, V9, P238
[5]
EFFECT OF FIBER CONDITIONING ON THE INTERFACIAL SHEAR-STRENGTH OF GLASS-FIBER COMPOSITES [J].
CHENG, TH ;
JONES, FR ;
WANG, D .
COMPOSITES SCIENCE AND TECHNOLOGY, 1993, 48 (1-4) :89-96
[6]
Eick JD, 1979, ACAD DENT MAT T, V10, P89
[7]
Ferracane JL, 1998, J BIOMED MATER RES, V42, P465, DOI 10.1002/(SICI)1097-4636(19981205)42:3<465::AID-JBM17>3.0.CO
[8]
2-F
[9]
Clinical evaluation of fiber-reinforced fixed bridges [J].
Freilich, MA ;
Meiers, JC ;
Duncan, JP ;
Eckrote, KA ;
Goldberg, J .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2002, 133 (11) :1524-1534
[10]
Load bearing capacity of fibre-reinforced and particulate filler composite resin combination [J].
Garoushi, S ;
Lassila, LVJ ;
Tezvergil, A ;
Vallittu, PK .
JOURNAL OF DENTISTRY, 2006, 34 (03) :179-184