Femoral neck strength of mouse in two loading configurations:: method evaluation and fracture characteristics

被引:35
作者
Jämsä, T [1 ]
Tuukkanen, J
Jalovaara, P
机构
[1] Univ Oulu, Tech Serv Unit, FIN-90220 Oulu, Finland
[2] Univ Oulu, Biomed Engn Program, FIN-90220 Oulu, Finland
[3] Univ Oulu, Dept Surg, FIN-90220 Oulu, Finland
[4] Univ Oulu, Dept Anat, FIN-90220 Oulu, Finland
关键词
loading angle; cervical fractures; murine model;
D O I
10.1016/S0021-9290(98)00087-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We evaluated the mechanical strength of murine femoral neck in two loading configurations. The mechanical strength of the left femora of 25 male mice (weight 39 +/- 4 g) were measured in an axial configuration simulating one-legged stance in a human, and the right femora were tested in a configuration simulating a fall to the lateral side, on the trochanter. The reproducibility of the mechanical testing was 1.6% in the axial configuration and 3.7% in the fall configuration. The femoral neck was slightly stronger in the fall configuration. Typically, a load in the fall direction associated with a basicervical fracture, while axial loading resulted in both mid- and basicervical fractures. The linear bivariate correlation coefficient between the mechanical strengths in the two loading configurations was 0.83. Total bone mineral content (BMC), cortical bone mineral content (CtBMC), volumetric cortical bone mineral density (vCtBMD), and cross-sectional cortical area (CSA), measured at the femoral neck by peripheral quantitative computed tomography (pQCT), had a significant relationship with the femoral neck strength in the axial configuration. The coefficient of variation of the pQCT measurements was 9.1, 5.5, 2.3 and 5.5% for BMC, CtBMC, vCtBMD and CSA, respectively. We conclude that the precision of pQCT is moderate in evaluating the femoral neck of the mouse, and vCtBMD is the most reproducible parameter. The mechanical strength of the murine femoral neck can be measured with high precision by the two mechanical testing configurations presented here. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:723 / 729
页数:7
相关论文
共 44 条
[1]  
ALHO A, 1988, CLIN ORTHOP RELAT R, P292
[2]   Transgenic mice expressing soluble tumor necrosis factor-receptor are protected against bone loss caused by estrogen deficiency [J].
Ammann, P ;
Rizzoli, R ;
Bonjour, JP ;
Bourrin, S ;
Meyer, JM ;
Vassalli, P ;
Garcia, I .
JOURNAL OF CLINICAL INVESTIGATION, 1997, 99 (07) :1699-1703
[3]   RECOVERY FROM DISUSE OSTEOPENIA COINCIDENT TO RESTORATION OF MUSCLE STRENGTH IN MDX MICE [J].
ANDERSON, JE ;
LENTZ, DL ;
JOHNSON, RB .
BONE, 1993, 14 (04) :625-634
[4]  
Augat P, 1996, J BONE MINER RES, V11, P1356
[5]  
Backman S, 1957, ACTA RADIOL S, V146, P1
[6]   Genetic variability in adult bone density among inbred strains of mice [J].
Beamer, WG ;
Donahue, LR ;
Rosen, CJ ;
Baylink, DJ .
BONE, 1996, 18 (05) :397-403
[7]   TRANSGENIC MOUSE MODEL OF THE MILD DOMINANT FORM OF OSTEOGENESIS IMPERFECTA [J].
BONADIO, J ;
SAUNDERS, TL ;
TSAI, E ;
GOLDSTEIN, SA ;
MORRISWIMAN, J ;
BRINKLEY, L ;
DOLAN, DF ;
ALTSCHULER, RA ;
HAWKINS, JE ;
BATEMAN, JF ;
MASCARA, T ;
JAENISCH, R .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (18) :7145-7149
[8]  
Breen SA, 1996, CALCIFIED TISSUE INT, V58, P449, DOI 10.1007/BF02509446
[9]   Assessment of the strength of proximal femur in vitro: Relationship to femoral bone mineral density and femoral geometry [J].
Cheng, XG ;
Lowet, G ;
Boonen, S ;
Nicholson, PHF ;
Brys, P ;
Nijs, J ;
Dequeker, J .
BONE, 1997, 20 (03) :213-218
[10]   AGE-RELATED REDUCTIONS IN THE STRENGTH OF THE FEMUR TESTED IN A FALL-LOADING CONFIGURATION [J].
COURTNEY, AC ;
WACHTEL, EF ;
MYERS, ER ;
HAYES, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (03) :387-395