Metabolite characterization in drug discovery utilizing robotic liquid-handling, quadruple time-of-flight mass spectrometry and in-silico prediction

被引:33
作者
Nassar, AEF [1 ]
Adams, PE [1 ]
机构
[1] Bayer Corp, Dept Pharmacokinet & Drug Metab, West Haven, CT 06516 USA
关键词
D O I
10.2174/1389200033489406
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
An assay method for identification of metabolites from in vitro microsomal incubations was developed for use in the early, stage of drug discovery. We have developed a Practical approach which involves integrated sample generation, sample preparation, bioanalysis, and data handling to maximize sample throughput and speed up the process for identification of metabolites. The assay system consisted of a robotic liquid handier (Genesis workstation) to generate and process samples, PALLAS MetabolExpert software to predict possible metabolites. exact mass measurement via a tandem quadrupole time-of-flight mass spectrometer (QTOF-MS) coupled with liquid chromatography to analyze samples, MetaboLynx software to find potential metabolites and Advanced Chemistry Development/MS (ACD/MS) software to provide guidance to the most likely hypothetical metabolite chemical Structures. For purposes of evaluating this new method, dextromethorphan, alprenolol. and propranolol were incubated separately for LIP to 60 minutes with rat and human hepatic microsomes. The incubation and sample preparation were carried Out in 96-well plates using the Genesis workstation. The bioanalysis was performed by LC-MS/MS using QTOF with MetaboLynx software to find metabolites. Metabolic products formed in vitro by rat and human microsomes were separated using an analytical column C18 with gradient elution at flow Late of 250 mul/min. The internal mass calibration was performed by Continuous postcolumn infusion of Haloperidol. The mass spectra from incubations containing NADPH were compared to those Without NADPH (control) using the MetabolLynx software to find potential metabolites. Finally, the MS/MS spectra were processed by the ACD/MS software to predict the chemical structure. MetaboLynx software Successfully identified metabolites for each of' tire drugs Studied by automatically discerning expected metabolites. Exact differences in masses between each metabolite and parent drug were measured from five replicate sample injections. All measured values arc accurate to less than 0.001 Da or 3.8 ppm with the standard deviation within 0.0015 Da, which allowed good prediction/confirmation of empirical formulae. Hypothetical chemical structures were achieved by tire ACD/MS software and provided a useful tool to assist in prediction of the metabolic pathways of the drugs. The metabolites identified were in good agreement with previously published results for all three compounds. This new, method will greatly enhance throughput, Which ill turn will facilitate our ability to rapidly provide this guidance to the synthetic chemist.
引用
收藏
页码:259 / 271
页数:13
相关论文
共 27 条
[1]  
Annesley TM, 2001, CLIN CHEM, V47, P910
[2]  
BAI SA, 1984, DRUG METAB DISPOS, V12, P749
[3]  
Bapiro TE, 2001, DRUG METAB DISPOS, V29, P30
[4]   High-performance liquid chromatography assay for simultaneous determination of dextromethorphan and its main metabolites in urine and in microsomal preparations [J].
Bendriss, EK ;
Markoglou, N ;
Wainer, IW .
JOURNAL OF CHROMATOGRAPHY B, 2001, 754 (01) :209-215
[5]   Estimating the precision of exact mass measurements on an orthogonal time-of-flight mass spectrometer [J].
Blom, KF .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :715-719
[6]   SIMULTANEOUS DETERMINATION OF DEXTROMETHORPHAN AND 3 METABOLITES IN PLASMA AND URINE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH APPLICATION TO THEIR DISPOSITION IN MAN [J].
CHEN, ZR ;
SOMOGYI, AA ;
BOCHNER, F .
THERAPEUTIC DRUG MONITORING, 1990, 12 (01) :97-104
[7]   The new time-of-flight mass spectrometry [J].
Cotter, RJ .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :445A-451A
[8]  
EBIHARA A, 1991, CLIN PHARM, V21, P351
[9]  
Fouda HG, 1997, DRUG METAB DISPOS, V25, P140
[10]  
Guilhaus M, 2000, MASS SPECTROM REV, V19, P65, DOI 10.1002/(SICI)1098-2787(2000)19:2<65::AID-MAS1>3.0.CO