Efficacy and tolerability of continuous overdrive atrial pacing in atrial fibrillation

被引:28
作者
Lam, CTF
Lau, CP [1 ]
Leung, SK
Tse, HF
Lee, KLF
Tang, MO
Tsang, V
机构
[1] Univ Hong Kong, Dept Med, Div Cardiol, Queen Mary Hosp, Hong Kong, Hong Kong, Peoples R China
[2] Univ Hong Kong, Queen Mary Hosp, Inst Cardiovasc Sci & Med, Hong Kong, Hong Kong, Peoples R China
[3] Kwong Wah Hosp, Dept Med & Geriatr, Hong Kong, Hong Kong, Peoples R China
来源
EUROPACE | 2000年 / 2卷 / 04期
关键词
atrial fibrillation; consistent atrial pacing; prevention of premature atrial complexes;
D O I
10.1053/eupc.2000.0124
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Overdrive right atrial pacing has been used to prevent atrial fibrillation, but its efficacy in atrial fibrillation prevention and the patient tolerability and quality of life during high rate pacing remain uncertain. The objective of this study was to lest the effects of a consistent atrial pacing algorithm that automatically paced the atrium at 30 ms shorter than the sinus P-P interval for atrial fibrillation prevention. Fifteen patients with sick sinus syndrome implanted with a Thera DR (model 7940 or 7960, Medhonic Inc.) were randomly programmed to rate adaptive dual chamber pacing (DDDR) or DDDR + consistent atrial pacing mode, each for an 8-week study period. The efficacy of consistent atrial pacing was assessed by the number of automatic mode switching and the number of premature atrial complexes. Symptoms and quality of life were assessed by the SF-36 quality of life questionnaire and an atrial fibrillation symptom checklist. The percentage of atrial pacing increased from 57 +/- 32% to 86 +/- 28%. Overall, there was no significant difference in the number of automatic mode switching episodes between DDDR and DDDR+ consistent atrial pacing (47 +/- 90 vs 42 +/- 87, P>0.05), but a significant reduction in premature atrial complexes by 74.7% (P<0.001). There was no undue increase in atrial rate by the DDDR+consistent atrial pacing mode versus DDDR (63 +/- 13 vs 70 +/- 7 bpm). There was no significant difference in quality of life scores and symptom severity on frequency between the two modes of pacing, but a trend towards a lower frequency of symptoms in the DDDR+consistent atrial pacing mode compared with baseline (29.5 +/- 10.2 vs 25.1 +/- 9.7, P=0.07). An algorithm that provides consistent atrial overdrive pacing can suppress atrial fibrillation triggering premature atrial complexes without the need to increase the overall atrial rate compared with conventional pacing. The algorithm appears to be well-tolerated, but further studies are needed to address the clinical impact of this atrial fibrillation prevention algorithm. (Europace 2000; 2: 286-291) (C) 2000 The European Society of Cardiology.
引用
收藏
页码:286 / 291
页数:6
相关论文
共 19 条
[1]   Long-term follow-up of patients from a randomised trial of atrial versus ventricular pacing for sick-sinus syndrome [J].
Andersen, HR ;
Nielsen, JC ;
Thomsen, PEB ;
Thuesen, L ;
Mortensen, PT ;
Vesterlund, T ;
Pedersen, AK .
LANCET, 1997, 350 (9086) :1210-1216
[2]   DDD PACING - AN EFFECTIVE TREATMENT MODALITY FOR RECURRENT ATRIAL ARRHYTHMIAS [J].
ATTUEL, P ;
PELLERIN, D ;
MUGICA, J ;
COUMEL, P .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11) :1647-1654
[3]   Dual-chamber versus ventricular pacing - Critical appraisal of current data [J].
Connolly, SJ ;
Kerr, C ;
Gent, M ;
Yasuf, S .
CIRCULATION, 1996, 94 (03) :578-583
[4]   Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes [J].
Connolly, SJ ;
Kerr, CR ;
Gent, M ;
Roberts, RS ;
Yusuf, S ;
Gillis, AM ;
Sami, MH ;
Talajic, M ;
Tang, ASL ;
Klein, GJ ;
Lau, C ;
Newman, DM .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (19) :1385-1391
[5]   Permanent left atrial pacing with a specifically designed coronary sinus lead [J].
Daubert, C ;
Leclercq, C ;
LeBreton, H ;
Gras, D ;
Pavin, D ;
Pouvreau, Y ;
VanVerooij, P ;
Bakels, N ;
Mabo, P .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (11) :2755-2764
[6]   Long-term outcome of patients with drug-refractory atrial flutter and fibrillation after single- and dual-site right atrial pacing for arrhythmia prevention [J].
Delfaut, P ;
Saksena, S ;
Prakash, A ;
Krol, RB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (07) :1900-1908
[7]   Design and implementation of the Dual Site Atrial Pacing to Prevent Atrial Fibrillation (DAPPAF) clinical trial [J].
Fitts, SM ;
Hill, MRS ;
Mehra, R ;
Friedman, P ;
Hammill, S ;
Kay, GN ;
Prakash, A ;
Webb, C ;
Saksena, S .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 1998, 2 (02) :139-144
[8]   Atrial pacing periablation for prevention of paroxysmal atrial fibrillation [J].
Gillis, AM ;
Wyse, DG ;
Connolly, SJ ;
Dubuc, M ;
Philippon, F ;
Yee, R ;
Lacombe, P ;
Rose, MS ;
Kerr, CD .
CIRCULATION, 1999, 99 (19) :2553-2558
[9]   Quality of life and clinical outcomes in elderly patients treated with ventricular pacing as compared with dual-chamber pacing [J].
Lamas, GA ;
Orav, J ;
Stambler, BS ;
Ellenbogen, KA ;
Sgarbossa, EB ;
Huang, SKS ;
Marinchak, RA ;
Estes, NAM ;
Mitchell, GF ;
Lieberman, EH ;
Mangione, CM ;
Goldman, L .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (16) :1097-1104
[10]  
LAU CP, 1999, PACE, V22, P804