Sensitivity and specificity of new GDx parameters

被引:32
作者
Colen, TP
Tang, NEML
Mulder, PGH
Lemij, HG
机构
[1] Rotterdam Eye Hosp, Glaucoma Serv, NL-3000 LM Rotterdam, Netherlands
[2] Erasmus Univ, Sch Med, Dept Biostat, NL-3000 DR Rotterdam, Netherlands
关键词
GDx; parameters; scanning laser polarimetry; sensitivity; specificity;
D O I
10.1097/00061198-200402000-00006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The GDx is a scanning laser polarimeter that assesses peripapillary nerve fiber layer thickness. In addition to the 14 existing outcome parameters, four new parameters have been described recently: the Ellipse Standard Deviation (ESD), the Normalized Superior Area (NSA), the Normalized Inferior Area (NIA) and the Discriminant Analysis (DA). The aim of this study was to investigate the sensitivity and specificity of these four new parameters. Methods: Only one randomly selected eye of 263 healthy volunteers and 241 glaucoma patients was considered. The healthy group was randomly divided into a reference set (n = 132) to calculate the tenth percentile of the normal distribution and a test set (n = 131) to calculate the specificity against these newly established cut-off points. Sensitivity was calculated for all glaucoma patients (n = 241) and again for three separate subgroups: early glaucoma (n = 90), moderate glaucoma (n = 93), and advanced glaucoma (n = 58). Results: When the tenth percentile of the normal distribution was used as a cut-off point, the sensitivity and specificity pairs of the new parameters were 61.8% and 87.6%, 61.8% and 89.1%, 50.2% and 92.2% and 72.6% and 95.3% for the ESD, NSA, NIA, and the DA, respectively. The Area under the ROC curve was 0.86, 0.86, 0.87, and 0.90, respectively. Among the existing parameters, the Number discriminated best (sensitivity and specificity: 76.8% and 89.1%, respectively; area under the ROC curve: 0.90). When compared with The Number, the DA was equally good, whereas the other three new parameters performed statistically significantly worse. In general, the area under the ROC curve increased from early to moderate to advanced glaucoma. Conclusions: The new GDx parameters discriminated well between normal subjects and glaucoma patients. None of the new parameters discriminated better than The Number.
引用
收藏
页码:28 / 33
页数:6
相关论文
共 18 条
[1]  
ANDERSON DR, 1999, AUTOMATED STAT PERIM, P104
[2]  
Bowd C, 2001, INVEST OPHTH VIS SCI, V42, P1993
[3]  
Chi Q M, 1995, J Glaucoma, V4, P406
[4]   Differentiating patients with glaucoma from glaucoma suspects and normal subjects by nerve fiber layer assessment with scanning laser polarimetry [J].
Choplin, NT ;
Lundy, DC ;
Dreher, AW .
OPHTHALMOLOGY, 1998, 105 (11) :2068-2076
[5]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[6]  
DREHER AW, 1992, CLIN VISION SCI, V7, P481
[7]   Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetry [J].
Greenfield, DS ;
Knighton, RW ;
Huang, XR .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (06) :715-722
[8]   Correction for corneal polarization axis improves the discriminating power of scanning laser polarimetry [J].
Greenfield, DS ;
Knighton, RW ;
Feuer, WJ ;
Schiffman, JC ;
Zangwill, L ;
Weinreb, RN .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 134 (01) :27-33
[9]   Variation of nerve fibre layer thickness measurements with age and ethnicity by scanning laser polarimetry [J].
Poinoosawmy, D ;
Fontana, L ;
Wu, JX ;
Fitzke, FW ;
Hitchings, RA .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1997, 81 (05) :350-354
[10]   Measurement by nerve fiber analyzer of retinal nerve fiber layer thickness in normal subjects and patients with ocular hypertension [J].
TjonFoSang, MJ ;
deVries, J ;
Lemij, HG .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1996, 122 (02) :220-227