Early Loading at 21 Days of Non-Submerged Titanium Implants With a Chemically Modified Sandblasted and Acid-Etched Surface: 3-Year Results of a Prospective Study in the Posterior Mandible

被引:53
作者
Bornstein, Michael M. [1 ]
Wittneben, Julia-Gabriela [2 ]
Bragger, Urs [2 ]
Buser, Daniel [1 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Oral Surg & Stomatol, CH-3010 Bern, Switzerland
[2] Univ Bern, Sch Dent Med, Dept Crown & Bridge Prosthet, CH-3010 Bern, Switzerland
关键词
Clinical trials; dental implants; osseointegration; RECOMMENDED CLINICAL PROCEDURES; TISSUE INTEGRATION; REMOVAL TORQUE; ITI IMPLANTS; SLA SURFACE; IMMUNOHISTOCHEMICAL ANALYSIS; PROSPECTIVE MULTICENTER; CONSENSUS STATEMENTS; SURGICAL-PROCEDURES; STRAUMANN IMPLANTS;
D O I
10.1902/jop.2010.090727
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Background: This study evaluates 3-year success rates of titanium screw-type implants with a chemically modified sandblasted and acid-etched surface (mod SLA), which were functionally loaded after 3 weeks of healing. Methods: A total of 56 implants, inserted in the posterior mandibles of 39 partially edentulous patients, underwent undisturbed healing for 3 weeks. At day 21, the implants were fully loaded with provisional crowns. Definitive metal ceramic restorations were fabricated after 6 months of healing. Clinical measurements regarding soft tissue parameters and radiographs were obtained at different time points up to 36 months after implant placement. The soft tissue and radiographic parameters for the mod SLA implants after 3 years in function were compared to a historic control group of implants with an SLA surface using an early loading protocol after 6 weeks. Results: None of the implants failed to integrate. However, two implants were considered "spinners" at day 21 and were left unloaded for an extended period. Therefore, 96.4% of the inserted implants were loaded according to the protocol tested. All 56 implants, including the "spinners," showed favorable clinical and radiographic findings at the 3-year follow-up examination. All 56 implants were considered successfully integrated, resulting in a 3-year survival and success rate of 100%. Dental implants with a mod SLA surface demonstrated statistically significant differences for probing depths and clinical attachment level values compared to the historic control group, with the mod SLA surface implants having overall lower probing depths and clinical attachment level scores. Conclusion: This prospective study using an early loading protocol demonstrates that titanium implants with the mod SLA surface can achieve and maintain successful tissue integration over a period of 3 years. J Periodontol 2010;81:809-818.
引用
收藏
页码:809 / 818
页数:10
相关论文
共 62 条
[1]
ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P347
[2]
OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[3]
[Anonymous], R: The R project for statistical computing
[4]
Aparicio Carlos, 2003, Clin Implant Dent Relat Res, V5, P57, DOI 10.1111/j.1708-8208.2003.tb00183.x
[5]
*ASA, PHYS STAT CLASS
[6]
A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years [J].
Berglundh, T ;
Persson, L ;
Klinge, B .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2002, 29 :197-212
[7]
Performance of dental implants after staged sinus floor elevation procedures: 5-year results of a prospective study in partially edentulous patients [J].
Bornstein, Michael M. ;
Chappuis, Vivianne ;
von Arx, Thomas ;
Buser, Daniel .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (10) :1034-1043
[8]
Bone apposition around two different sandblasted and acid-etched titanium implant surfaces: a histomorphometric study in canine mandibles [J].
Bornstein, Michael M. ;
Valderrama, Pilar ;
Jones, Archie A. ;
Wilson, Thomas G. ;
Seibl, Reinhart ;
Cochran, David L. .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (03) :233-241
[9]
Early Loading of Nonsubmerged Titanium Implants with a Chemically Modified Sand-Blasted and Acid-Etched Surface: 6-Month Results of a Prospective Case Series Study in the Posterior Mandible Focusing on Peri-Implant Crestal Bone Changes and Implant Stability Quotient (ISQ) Values [J].
Bornstein, Michael M. ;
Hart, Christopher N. ;
Halbritter, Sandro A. ;
Morton, Dean ;
Buser, Daniel .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2009, 11 (04) :338-347
[10]
Bornstein MM, 2008, INT J ORAL MAX IMPL, V23, P1109