An improved X-ray detector for use at synchrotrons

被引:52
作者
Thoms, M
Bauchau, S
Hausermann, D
Kunz, M
Le Bihan, T
Mezouar, M
Strawbridge, D
机构
[1] Univ Erlangen Nurnberg, Inst Mat Sci 6, D-91058 Erlangen, Germany
[2] European Synchrotron Radiat Facil, F-38043 Grenoble 09, France
关键词
BaFBr : Eu; image plate; image readout; light scattering; X-ray absorption; X-ray sensitivity; photon diffusion; photostimulation; photostimulated luminescence; sensitivity; storage phosphor;
D O I
10.1016/S0168-9002(98)00199-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Due to the advent of synchrotrons as X-ray sources with high power and brilliance new improved X-ray detectors are needed in order to make efficient use of the unique features of the synchrotron radiation. In this article the construction and characteristics of an X-ray detector, which is based on image plates and which has been especially designed for the detection of X-ray images at synchrotrons is reported. The detector has an X-ray sensitive area of 250 mm x 305 mm, and allows the acquisition of X-ray images with variable pixel sizes and readout speeds according to the requirements of the particular experiment. In the normal setup mode images can be recorded every 13 s using a pixel size of 80 mu m x 80 mu m, which relates to 12 x 10(6) pixels per image, while in the high-resolution setup images can be recorded every 41 s with 40 mu m x 40 mu m pixel size, which relates to 48 x 10(6) pixels per image. The relation of detector characteristics, such as readout speed, resolution and efficiency to the physical processes of image storage and readout are discussed. Examples of images taken during the first test experiment on the high-pressure beamline (ID30) of the ESRF are presented. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:175 / 184
页数:10
相关论文
共 12 条
[1]   DESIGN AND PERFORMANCE OF AN IMAGING PLATE SYSTEM FOR X-RAY-DIFFRACTION STUDY [J].
AMEMIYA, Y ;
MATSUSHITA, T ;
NAKAGAWA, A ;
SATOW, Y ;
MIYAHARA, J ;
CHIKAWA, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3) :645-653
[2]   Application of an imaging plate to the large-volume press MAX80 at the photon factory [J].
Chen, J ;
Kikegawa, T ;
Shimomura, O ;
Iwasaki, H .
JOURNAL OF SYNCHROTRON RADIATION, 1997, 4 :21-27
[3]   IMAGE PLATE DETECTORS FOR MACROMOLECULAR NEUTRON DIFFRACTOMETRY [J].
CIPRIANI, F ;
DAUVERGNE, F ;
GABRIEL, A ;
WILKINSON, C ;
LEHMANN, MS .
BIOPHYSICAL CHEMISTRY, 1994, 53 (1-2) :5-13
[4]   TEMPERATURE-DEPENDENCE OF THE PHOTOSTIMULATED LUMINESCENCE OF X-IRRADIATED BAFBR-EU-2+ [J].
HANGLEITER, T ;
KOSCHNICK, FK ;
SPAETH, JM ;
NUTTALL, RHD ;
EACHUS, RS .
JOURNAL OF PHYSICS-CONDENSED MATTER, 1990, 2 (32) :6837-6846
[5]   A NEW TYPE OF X-RAY AREA DETECTOR UTILIZING LASER STIMULATED LUMINESCENCE [J].
MIYAHARA, J ;
TAKAHASHI, K ;
AMEMIYA, Y ;
KAMIYA, N ;
SATOW, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :572-578
[6]   The dynamic range of X-ray imaging with image plates [J].
Thoms, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 389 (03) :437-440
[7]   An improved X-ray image plate detector for diffractometry [J].
Thoms, M ;
Burzlaff, H ;
Kinne, A ;
Lange, J ;
vonSeggern, H ;
Spengler, R ;
Winnacker, A .
EUROPEAN POWDER DIFFRACTION: EPDIC IV, PTS 1 AND 2, 1996, 228 :107-112
[8]   Radiographic imaging with image plates: The influence of the readout intensity on the image quality [J].
Thoms, M ;
vonSeggern, H .
JOURNAL OF APPLIED PHYSICS, 1997, 81 (09) :5887-5895
[9]   Image properties of polycrystalline storage films [J].
Thoms, M .
APPLIED OPTICS, 1996, 35 (19) :3702-3714
[10]   SPATIAL CORRELATION AND PHOTOSTIMULABILITY OF DEFECT CENTERS IN THE X-RAY-STORAGE PHOSPHOR BAFBR-EU2+ [J].
THOMS, M ;
VONSEGGERN, H ;
WINNACKER, A .
PHYSICAL REVIEW B, 1991, 44 (17) :9240-9247