Magnetic resonance imaging based digitally reconstructed radiographs, virtual simulation, and three-dimensional treatment planning for brain neoplasms

被引:25
作者
Ramsey, CR [1 ]
Oliver, AL [1 ]
机构
[1] Thompson Canc Survival Ctr, Dept Radiat Oncol, Knoxville, TN 37916 USA
关键词
magnetic resonance imaging; digitally reconstructed radiographs; three-dimensional treatment planning; virtual simulation;
D O I
10.1118/1.598382
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Currently, patients with brain neoplasms must undergo both computed tomography (CT) and magnetic resonance (MR) imaging to take advantage of CT's density information and MR's soft tissue imaging capabilities. A method has been developed that allows virtual simulation, digitally reconstructed radiographs (DRRs), and 3-D treatment planning of patients with brain neoplasms to be generated using only one T1-weighted MR data set. DRRs of an anthropomorphic RANDO head phantom were generated using MR and CT imaging. The MR based DRRs provided structural information equivalent to CT based DRRs. The spatial linearity of CT and MR image sets was evaluated by measuring the percent distortion and spatial error. There was no statistical difference in spatial linearity or accuracy between the CT and MR image sets. MR and CT based treatment planning were compared using a variety of different treatment accessories, field sizes, photon energies, and gantry positions. Doses at various points throughout the head phantom were used as comparison points between CT based heterogeneous, CT based homogenous, and MR based homogenous treatment planning of the head phantom. Lithium fluoride thermoluminescent dosimeters were used to verify the dosimetric accuracy of MR based treatment planning by taking measurements at these points. For treatment plans with fields that pass through large air cavities, such as the maxillary sinus, homogenous treatment planning produces unacceptable dosimetric error (2%-4%). For treatment plans with fields that pass through the skull, MR homogenous treatment planning can be used with a dosimetric accuracy of +/-2%. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)01810-0].
引用
收藏
页码:1928 / 1934
页数:7
相关论文
共 15 条
[1]  
*AAPM TASK GROUP, 1995, RAD TREATM PLANN DOS
[2]   Application of AAPM Radiation Therapy Committee Task Group 23 test package for comparison of two treatment planning systems for photon external beam radiotherapy [J].
Alam, R ;
Ibbott, GS ;
Pourang, R ;
Nath, R .
MEDICAL PHYSICS, 1997, 24 (12) :2043-2054
[3]   INTEGRATION OF MAGNETIC-RESONANCE-IMAGING INTO RADIATION-THERAPY TREATMENT PLANNING .1. TECHNICAL CONSIDERATIONS [J].
FRAASS, BA ;
MCSHAN, DL ;
DIAZ, RF ;
TENHAKEN, RK ;
AISEN, A ;
GEBARSKI, S ;
GLAZER, G ;
LICHTER, AS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (12) :1897-1908
[4]   MULTIDIMENSIONAL TREATMENT PLANNING .2. BEAM EYE-VIEW, BACK PROJECTION, AND PROJECTION THROUGH CT SECTIONS [J].
GOITEIN, M ;
ABRAMS, M ;
ROWELL, D ;
POLLARI, H ;
WILES, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (06) :789-797
[5]   HUMAN CEREBRAL GLIOMAS - CORRELATION OF POSTMORTEM MR IMAGING AND NEUROPATHOLOGIC FINDINGS [J].
JOHNSON, PC ;
HUNT, SJ ;
DRAYER, BP .
RADIOLOGY, 1989, 170 (01) :211-217
[6]   A CONVOLUTION METHOD OF CALCULATING DOSE FOR 15-MV X-RAYS [J].
MACKIE, TR ;
SCRIMGER, JW ;
BATTISTA, JJ .
MEDICAL PHYSICS, 1985, 12 (02) :188-196
[7]   GENERATION OF PHOTON ENERGY DEPOSITION KERNELS USING THE EGS MONTE-CARLO CODE [J].
MACKIE, TR ;
BIELAJEW, AF ;
ROGERS, DWO ;
BATTISTA, JJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (01) :1-20
[8]   INVESTIGATION OF THE CONVOLUTION METHOD FOR POLYENERGETIC SPECTRA [J].
PAPANIKOLAOU, N ;
MACKIE, TR ;
MEGERWELLS, C ;
GEHRING, M ;
RECKWERDT, P .
MEDICAL PHYSICS, 1993, 20 (05) :1327-1336
[9]  
PRICE RR, 1988, MRI ACCEPTANCE TESTI, P18
[10]  
Purdy JA, 1997, PRINCIPALS PRACTICE, P343