Transfer of normal 99mTc-ECD brain SPET databases between different gamma cameras

被引:28
作者
Van Laere, K
Koole, M
Versijpt, J
Vandenberghe, S
Brans, B
D'Asseler, Y
De Winter, O
Kalmar, A
Dierckx, R
机构
[1] Ghent Univ Hosp, Div Nucl Med, B-9000 Ghent, Belgium
[2] Univ Ghent, Fac Sci Appl, Dept Med Signal & Image Proc, Ghent, Belgium
关键词
regional cerebral blood flow; Tc-99m-ECD; normal database; resolution;
D O I
10.1007/s002590000461
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A stereotactic, normal perfusion database is imperative for optimal clinical brain single-photon emission tomography (SPET). However, interdepartmental use of normal data necessitates accurate transferability of these data sets. The aim of this study was to investigate transfer of three normal perfusion databases obtained in the same large population of healthy volunteers who underwent sequential scanning using multihead gamma cameras with different resolution. Eighty-nine healthy adults (46 females, 43 males; aged 20-81 years) were thoroughly screened by history, biochemistry, physical and full neurological examination, neuropsychological testing and magnetic resonance imaging. After injection of 925 MBq technetium-99m labelled ethyl cysteinate dimer (ECD) under standard conditions, 101 scans were acquired from all subjects (12 repeat studies) on a triple-head Toshiba GCA-9300A (measured average FWHM 8.1 mm). Ninety-one sequential scans were performed on a dual-head Elscint Helix camera (FWHM 9.6 mm) and 22 subjects also underwent imaging on a triple-head Prism 3000 (FWHM 9.6 mm). Images were transferred to the same processing platform and reconstructed by filtered back-projection with the same Butterworth filter (order 8, cut-off 0.9 cycles/cm) and uniform Sorensen attenuation correction (mu =0.09). After automated rigid intrasubject registration, all subjects were automatically reoriented to a stereotactic template by a nine-parameter affine transformation. The databases were analysed using 35 predefined volumes of interest (VOIs) with normalisation on total VOI counts. For comparison, the high-resolution data were smoothed with a 3D Gaussian kernel to achieve moro similar spatial resolution. Hoffman phantom measurements were conducted on all cameras. Partial volume effects after smoothing varied between -6.5% and 10%, depending on VOI size. Between-camera reproducibility was 2.5% and 2.7% for the Toshiba camera versus the Helix and the Prism database, respectively. The highest reduction in between-camera variability was achieved by resolution adjustment in combination with linear washout correction and a Hoffman phantom-based correction. In conclusion, transfer of normal perfusion data between multihead gamma cameras can be accurately achieved, thereby enabling widespread interdepartmental use, which is likely to have a positive impact on the diagnostic capabilities of clinical brain perfusion SPET.
引用
收藏
页码:435 / 449
页数:15
相关论文
共 33 条
[1]  
ACTON PD, 1998, NUCL MED CLIN DIAGNO, P613
[2]  
Asenbaum S, 1998, J NUCL MED, V39, P613
[3]   Transmission scanning in emission tomography [J].
Bailey, DL .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (07) :774-787
[4]   Age-specific cerebral perfusion in 4- to 15-year-old children: a high-resolution brain SPET study using Tc-99m-ECD [J].
Barthel, H ;
Wiener, M ;
Dannenberg, C ;
Bettin, S ;
Sattler, B ;
Knapp, WH .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (10) :1245-1252
[5]  
Barthel H, 1999, NUKLEARMED, V38, P80
[6]  
BRIGGS G G, 1975, Cortex, V11, P230
[7]   Age related cognitive decline: A clinical entity? A longitudinal study of cerebral blood flow and memory performance [J].
Celsis, P ;
Agniel, A ;
Cardebat, D ;
Demonet, JF ;
Ousset, PJ ;
Puel, M .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1997, 62 (06) :601-608
[8]   Retention of Tc-99m ECD in delayed SPECT of the brain [J].
Flores, LG ;
Jinnouchi, S ;
Nagamachi, S ;
Ohnishi, T ;
Futami, S ;
Nakahara, H ;
Shimoshinbara, S ;
Ushinbana, K ;
Tamura, S .
ANNALS OF NUCLEAR MEDICINE, 1999, 13 (01) :1-4
[9]   ENHANCED DETECTION OF FOCAL BRAIN RESPONSES USING INTERSUBJECT AVERAGING AND CHANGE-DISTRIBUTION ANALYSIS OF SUBTRACTED PET IMAGES [J].
FOX, PT ;
MINTUN, MA ;
REIMAN, EM ;
RAICHLE, ME .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (05) :642-653
[10]   Spatial registration and normalization of images [J].
Friston, KJ ;
Ashburner, J ;
Frith, CD ;
Poline, JB ;
Heather, JD ;
Frackowiak, RSJ .
HUMAN BRAIN MAPPING, 1995, 3 (03) :165-189