Predictors of atrial antitachycardia pacing efficacy in patients affected by Brady-Tachy form of sick sinus syndrome and implanted with a DDDRP device

被引:16
作者
Boriani, G
Padeletti, L
Santini, M
Gulizia, M
Capucci, A
Botto, G
Ricci, R
Molon, G
Accogli, M
Vicentini, A
Biffi, M
Vimercati, M
Grammatico, A
机构
[1] Univ Bologna, Inst Cardiol, Osped S Orsola Malphigi, I-40138 Bologna, Italy
[2] Univ Florence, Med Clin, Dept Cardiol, I-50121 Florence, Italy
[3] S Filippo Neri Hosp, Dept Cardiol, Rome, Italy
[4] S Curro Hosp, Dept Cardiol, Catania, Italy
[5] Civile Hosp, Dept Cardiol, Piacenza, Italy
[6] St Anna Hosp, Dept Cardiol, Como, Italy
[7] S Cuore Hosp, Dept Cardiol, Negrar, Italy
[8] Panico Hosp, Dept Cardiol, Tricase, Italy
[9] Casa Cura Pederzoli, Dept Cardiol, Peschiera, Italy
关键词
antitachycardia pacing; termination efficacy predictors; atrial fibrillation;
D O I
10.1111/j.1540-8167.2005.40716.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Recent options to treat atrial tachyarrhythmias (ATA) include implantable devices delivering antitachycardia pacing therapies (ATP). No prospective study selected patients with higher chances of episode termination by ATP or indicated the most effective ATP use. Our aim was to study ATP efficacy in patients with brady-tachy form of sinus node disease (SND), identifying clinical factors, ATA characteristics, and device features predicting ATP efficacy. Methods and Results: Three hundred and sixteen patients (105 M, aged 71.1 +/- 8.8 years) received a DDDRP pacemaker and were prospectively followed. Median follow-up was 18 months: 37,125 ATA episodes occurred in 217 patients; ATP treated 5,536 of them. Overall, ATP efficacy was 50.0%. A multivariate analysis identified longer arrhythmia cycle lengths (OR = 1.25; CI = 1.07-1.47) and shorter delays to ATP delivery (OR = 0.15; CI = 0.10-0.22) as independent predictors of ATP efficacy for episodes preceded by >= 5 minutes of sinus rhythm. Additionally, ATP efficacy for all treated episodes was predicted by lower New York Heart Association (NYHA) class (OR = 0.64; CI = 0.42-0.98), episode classification as nonimmediate recurrence of ATA (non-IRAT) (OR = 0.07; CI = 0.02-0.33), absence of overlap in the device detection windows (OR = 0.54; CI = 0.32-0.91), and flecainide treatment (OR = 2.22; CI = 1.04-4.71). Conclusions: In patients paced for SND, multivariate analysis shows that ATP efficacy is associated to longer arrhythmia cycle lengths, shorter ATP delivery delays, NYHA class I, episode classification as non-IRAT, absence of overlap in the atrial arrhythmia device detection windows, and flecainide treatment.
引用
收藏
页码:714 / 723
页数:10
相关论文
共 43 条
  • [1] Efficacy of pacing therapies for treating atrial tachyarrhythmias in patients with ventricular arrhythmias receiving a dual-chamber implantable cardioverter defibrillator
    Adler, SW
    Wolpert, C
    Warman, EN
    Musley, SK
    Koehler, JL
    Euler, DE
    [J]. CIRCULATION, 2001, 104 (08) : 887 - 892
  • [2] Long-term follow-up of patients from a randomised trial of atrial versus ventricular pacing for sick-sinus syndrome
    Andersen, HR
    Nielsen, JC
    Thomsen, PEB
    Thuesen, L
    Mortensen, PT
    Vesterlund, T
    Pedersen, AK
    [J]. LANCET, 1997, 350 (9086) : 1210 - 1216
  • [3] Impact of atrial fibrillation on the risk of death
    Benjamin, EJ
    Wolf, PA
    D'Agostino, RB
    Silbershatz, H
    Kannel, WB
    Levy, D
    [J]. CIRCULATION, 1998, 98 (10) : 946 - 952
  • [4] Electrophysiological effects of flecainide and propafenone on atrial fibrillation cycle and relation with arrhythmia termination
    Biffi, M
    Boriani, G
    Bronzetti, G
    Capucci, A
    Branzi, A
    Magnani, B
    [J]. HEART, 1999, 82 (02) : 176 - 182
  • [5] Atrial pacing for prevention of atrial fibrillation: assessment of simultaneously implemented algorithms
    Blanc, JJ
    De Roy, L
    Mansourati, J
    Poezevara, Y
    Marcon, JL
    Schoels, W
    Hidden-Lucet, F
    Barnay, C
    [J]. EUROPACE, 2004, 6 (05): : 371 - 379
  • [6] Favorable effects of flecainide in transvenous internal cardioversion of atrial fibrillation
    Boriani, G
    Biffi, M
    Capucci, A
    Bronzetti, G
    Ayers, GM
    Zannoli, R
    Branzi, A
    Magnani, B
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (02) : 333 - 341
  • [7] Rate control in atrial fibrillation - Choice of treatment and assessment of efficacy
    Boriani, G
    Biffi, M
    Diemberger, I
    Martignani, C
    Branzi, A
    [J]. DRUGS, 2003, 63 (14) : 1489 - 1509
  • [8] Current clinical perspectives on implantable devices for atrial defibrillation
    Boriani, G
    Biffi, M
    Martignani, C
    Luceri, R
    Bartolini, P
    Branzi, A
    [J]. CURRENT OPINION IN CARDIOLOGY, 2002, 17 (01) : 82 - 89
  • [9] Effects of consistent atrial pacing and atrial rate stabilization - two pacing algorithms to suppress recurrent paroxysmal atrial fibrillation in brady-tachy syndrome
    Boriani, G
    Biffi, M
    Padeletti, L
    Spampinato, A
    Botto, GL
    Pignalberi, C
    Grammatico, A
    Hettrick, DA
    De Seta, F
    Branzi, A
    [J]. EUROPEAN HEART JOURNAL SUPPLEMENTS, 2001, 3 (0P) : P7 - P15
  • [10] A new pacemaker algorithm for the treatment of atrial fibrillation - Results of the Atrial Dynamic Overdrive Pacing Trial (ADOPT)
    Carlson, MD
    Ip, J
    Messenger, J
    Beau, S
    Kalbfleisch, S
    Gervais, P
    Cameron, DA
    Duran, A
    Val-Mejias, J
    Mackall, J
    Gold, M
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (04) : 627 - 633