Advances in the Raman depth profiling of polymer laminates

被引:47
作者
Froud, CA [1 ]
Hayward, IP
Laven, J
机构
[1] Univ Southampton, Optoelect Res Ctr, Dept Chem, Southampton SO17 1BJ, Hants, England
[2] Renishaw Plc, Spect Prod Div, Wotton Under Edge GL12 7DW, Glos, England
[3] Eindhoven Univ Technol, NL-5600 MB Eindhoven, Netherlands
关键词
confocal Raman microscopy; depth resolution; refraction; depth profiling; oil immersion; polymer laminates; cross-sectioning;
D O I
10.1366/000370203322640099
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 [仪器科学与技术]; 080401 [精密仪器及机械]; 081102 [检测技术与自动化装置];
摘要
The use of Raman microspectroscopy to depth profile multi-layered polymer laminates is becoming increasingly popular. However, the results are generally degraded by aberrations introduced by the change in refractive index at the air/sample interface. Recent research has suggested that the use of an immersion oil and suitable objective can reduce this effect. This study evaluates this proposal by comparing depth profiling results on a multi-layer poly(styrene)/poly(methylmethacrylate) (PS/PMMA) laminate polymer from both dry metallurgical objectives and immersion objectives (used in combination with an oil of suitable refractive index). The immersion technique enabled successful depth profiling to the full working distance of the objective (100 mum), showing clear and distinct variations in 11 different layers within the laminate; a dry metallurgical objective used for comparison achieved poor resolution of only two layers. This is the first demonstration of depth profiling within a polymer laminate to this depth. The depth profiling results are compared to results obtained by sectioning the PS/PMMA sample after setting it in resin.
引用
收藏
页码:1468 / 1474
页数:7
相关论文
共 8 条
[1]
Confocal Raman microspectroscopy through a planar interface [J].
Baldwin, KJ ;
Batchelder, DN .
APPLIED SPECTROSCOPY, 2001, 55 (05) :517-524
[2]
Confocal Raman microscopy: Why the depth resolution and spatial accuracy can be much worse than you think [J].
Everall, NJ .
APPLIED SPECTROSCOPY, 2000, 54 (10) :1515-1520
[3]
Modeling and measuring the effect of refraction on the depth resolution of confocal Raman microscopy [J].
Everall, NJ .
APPLIED SPECTROSCOPY, 2000, 54 (06) :773-782
[4]
Depth profiling of polg(methyl methacrylate), poly(vinyl alcohol) laminates by confocal Raman microspectroscopy [J].
Hajatdoost, S ;
Yarwood, J .
APPLIED SPECTROSCOPY, 1996, 50 (05) :558-564
[5]
Confocal Raman depth profiling of surface-modified polymer films:: Effects of sample refractive index [J].
Reinecke, H ;
Spells, SJ ;
Sacristán, J ;
Yarwood, J ;
Mijangos, C .
APPLIED SPECTROSCOPY, 2001, 55 (12) :1660-1664
[6]
Sommer AJ, 1998, TECH ANAL CHEM SER, P291
[7]
CONFOCAL RAMAN MICROSPECTROSCOPY - THEORY AND APPLICATION TO THIN POLYMER SAMPLES [J].
TABAKSBLAT, R ;
MEIER, RJ ;
KIP, BJ .
APPLIED SPECTROSCOPY, 1992, 46 (01) :60-68
[8]
CONFOCAL RAMAN MICROSPECTROSCOPY USING A STIGMATIC SPECTROGRAPH AND CCD DETECTOR [J].
WILLIAMS, KPJ ;
PITT, GD ;
BATCHELDER, DN ;
KIP, BJ .
APPLIED SPECTROSCOPY, 1994, 48 (02) :232-235