Simultaneous quantification of polar and non-polar volatile organic compounds in water samples by direct aqueous injection-gas chromatography/mass spectrometry

被引:46
作者
Aeppli, Christoph [1 ]
Berg, Michael [1 ]
Hofstetter, Thomas B. [2 ]
Kipfer, Rolf [1 ]
Schwarzenbach, Rene P. [2 ]
机构
[1] Eawag, Swiss Fed Inst Aquat Sci & Technol, CH-8600 Dubendorf, Switzerland
[2] ETH, Inst Biogeochem & Pollutant Dynam IBP, CH-8092 Zurich, Switzerland
关键词
VOC; analysis; groundwater; environmental aqueous samples; carbon tetrachloride; chlorobenzene; chloroform; 1,2-dichlorobenzene; 1,4-dichlorobenzene; 1,2-dichloroethane; 1,2-dichloropropane; 1,1,1-trichloroethane; 1,3-dichlorobenzene; trichloroethene; 1,1-dichloroethene; trans-1,2-dichloroethene; cis-1,2-dichloroethene; perchloroethene; vinyl chloride; dichloromethane; benzene; toluene; xylene; methyl tert-butyl ether (MTBE); tert-butyl alcohol (TBA); ELECTRON-CAPTURE DETECTION; TERT-BUTYL ETHER; MASS-SPECTROMETRY; TRACE ANALYSIS; DEGRADATION-PRODUCTS; ISOTOPE ANALYSIS; SURFACE-WATER; GC; TRIHALOMETHANES; GROUNDWATER;
D O I
10.1016/j.chroma.2007.12.043
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A direct aqueous injection-gas chromatography/mass spectrometry (DAI-GC/MS) method for trace analysis of 24 volatile organic compounds (VOCs) in water samples is presented. The method allows for the simultaneous quantification of benzene, toluene, ethyl benzene, and xylenes (BTEX), methyl tert-butyl ether (MTBE), tert-butyl alcohol (TBA), as well as a variety of chlorinated methanes, ethanes, propane, enthenes and benzenes. Applying a liquid film polyethylene glycol or a porous layer open tubular (PLOT) divinylbenzene GC capillary column to separate the water from the VOCs, volumes of 1-10 mu L aqueous sample are directly injected into the GC. No enrichment or pretreatment steps are required and sample volumes as low as 100 mu L are sufficient for accurate quantification. Method detection limits determined in natural groundwater samples were between 0.07 and 2.8 mu g/L and instrument detection tin-tits of < 5 pg were achieved for 21 out of the 24 evaluated VOCs. DAI-GC/MS offers both good accuracy and precision (relative standard deviations <= 10%). The versatility of our method is demonstrated for contaminant quantification in drinking water disinfection (advanced oxidation of MTBE) and for VOC concentration measurements in a polluted aquifer. The wide range of detectable compounds and the lack of labor-intensive sample preparation illustrate that the DAI method is robust and easily applicable for the quantification of important organic groundwater contaminants. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:116 / 124
页数:9
相关论文
共 32 条
[1]   Henry's law constants for a diverse set of organic chemicals: Experimental determination and comparison of estimation methods [J].
Altschuh, J ;
Bruggemann, R ;
Santl, H ;
Eichinger, G ;
Piringer, OG .
CHEMOSPHERE, 1999, 39 (11) :1871-1887
[2]  
[Anonymous], 2004, World Health Organization Guidelines for Drinking Water Quality, V1
[3]  
CARMICHAEL D, 1990, HRC-J HIGH RES CHROM, V13, P267
[4]   Method for determination of methyl tert-butyl ether and its degradation products in water [J].
Church, CD ;
Isabelle, LM ;
Pankow, JF ;
Rose, DL ;
Tratnyek, PG .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (12) :3723-3726
[5]   Comparison of methods for determination of volatile organic compounds in drinking water [J].
Golfinopoulos, SK ;
Lekkas, TD ;
Nikolaou, AD .
CHEMOSPHERE, 2001, 45 (03) :275-284
[6]   ON-COLUMN INJECTION ON TO GLASS CAPILLARY COLUMNS [J].
GROB, K ;
GROB, K .
JOURNAL OF CHROMATOGRAPHY, 1978, 151 (03) :311-320
[7]   TRACE ANALYSIS OF HALOCARBONS IN WATER - DIRECT AQUEOUS INJECTION WITH ELECTRON-CAPTURE DETECTION [J].
GROB, K ;
HABICH, A .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1983, 6 (01) :11-15
[8]   FURTHER DEVELOPMENT OF DIRECT AQUEOUS INJECTION WITH ELECTRON-CAPTURE DETECTION IN GAS-CHROMATOGRAPHY [J].
GROB, K .
JOURNAL OF CHROMATOGRAPHY, 1984, 299 (01) :1-11
[9]   ENVIRONMENTAL-ANALYSIS BY DIRECT AQUEOUS INJECTION [J].
GURKA, DF ;
PYLE, SM ;
TITUS, R .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1749-1754
[10]   DIRECT ANALYSIS OF WATER SAMPLES FOR ORGANIC POLLUTANTS WITH GAS CHROMATOGRAPHY MASS SPECTROMETRY [J].
HARRIS, LE ;
BUDDE, WL ;
EICHELBERGER, JW .
ANALYTICAL CHEMISTRY, 1974, 46 (13) :1912-1917