Study of the parameters affecting operator doses in interventional radiology using Monte Carlo simulations

被引:71
作者
Koukorava, C. [1 ,4 ]
Carinou, E. [1 ]
Ferrari, P. [2 ]
Krim, S. [3 ]
Struelens, L. [3 ]
机构
[1] GAEC, Athens 15310, Greece
[2] ENEA Radiat Protect Inst, I-40136 Bologna, Italy
[3] CEN SCK, Belgian Nucl Res Ctr, B-2400 Mol, Belgium
[4] Univ Athens, Sch Med, Dept Med Phys, GR-11527 Athens, Greece
关键词
Interventional radiology; Occupational doses; Extremity dosimetry; Eye lens dosimetry; Monte Carlo simulations; EXTREMITY; STAFF;
D O I
10.1016/j.radmeas.2011.06.057
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
070305 [高分子化学与物理]; 080810 [电力电子与电能变换];
摘要
Measurements performed performed within the ORAMED project helped to evaluate the dose levels to the operators' hands, wrists, legs and eye lenses, during several types of interventional radiology (IR) and cardiology (IC) procedures, and also to determine the parameters that affect the doses. However, the study of the effect of each parameter separately, was possible only through Monte Carlo (MC) simulations, as in clinical practice many of those parameters change simultaneously. The influence of the protective equipment, the beam projections, the beam quality, the field size and the position of the operator according to the position of access of the catheter was investigated, using anthropomorphic phantoms in setups that represent realistic IR/IC procedures. The proper use of protective shields was found to be the most important way of reducing extremity and eye lens exposure during such examinations. Ceiling suspended shields can reduce the doses to the eye lenses up to 97%, but they can also reduce hand doses about 70% when placed correctly. The highest exposure to the operator is observed for left anterior oblique (LAO) and cranial projections. Additionally, for overcouch irradiations the eyes and the hands are about 6 times more exposed compared to the cases where the tube is below the operating table. For the lateral LAO projection, placing the ceiling suspended shield at the left side of the operator is twice more effective for the protection of the eyes compared to the cases where it is placed above the patient. Finally, beam collimation was found to play an important role in the reduction of the hands and wrists doses, especially when the operator is close to the irradiation field. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1216 / 1222
页数:7
相关论文
共 9 条
[1]
MONTE CARLO CALCULATIONS ON EXTREMITY AND EYE LENS DOSIMETRY FOR MEDICAL STAFF AT INTERVENTIONAL RADIOLOGY PROCEDURES [J].
Carinou, E. ;
Ferrari, P. ;
Koukorava, C. ;
Krim, S. ;
Struelens, L. .
RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) :492-496
[2]
EXTREMITY AND EYE LENS DOSES IN INTERVENTIONAL RADIOLOGY AND CARDIOLOGY PROCEDURES: FIRST RESULTS OF THE ORAMED PROJECT [J].
Domienik, J. ;
Brodecki, M. ;
Carinou, E. ;
Donadille, L. ;
Jankowski, J. ;
Koukorava, C. ;
Krim, S. ;
Nikodemova, D. ;
Ruiz-Lopez, N. ;
Sans-Merce, M. ;
Struelens, L. ;
Vanhavere, F. .
RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) :442-447
[3]
Staff eye lens and extremity exposure in interventional cardiology: Results of the ORAMED project [J].
Donadille, L. ;
Carinou, E. ;
Brodecki, M. ;
Domienik, J. ;
Jankowski, J. ;
Koukorava, C. ;
Krim, S. ;
Nikodemova, D. ;
Ruiz-Lopez, N. ;
Sans-Merce, M. ;
Struelens, L. ;
Vanhavere, F. ;
Zaknoune, R. .
RADIATION MEASUREMENTS, 2011, 46 (11) :1203-1209
[4]
Staff extremity doses in interventional radiology. Results of the ORAMED measurement campaign [J].
Nikodemova, D. ;
Brodecki, M. ;
Carinou, E. ;
Domienik, J. ;
Donadille, L. ;
Koukorava, C. ;
Krim, S. ;
Ruiz-Lopez, N. ;
Sans-Merce, M. ;
Struelens, L. ;
Vanhavere, F. ;
Zaknoune, R. .
RADIATION MEASUREMENTS, 2011, 46 (11) :1210-1215
[5]
Pelowitz DB., 2005, LACP050369
[6]
Monte Carlo calculations for assessment of radiation dose to patients with congenital heart defects and to staff during cardiac catheterizations [J].
Schultz, FW ;
Geleijns, J ;
Spoelstra, FM ;
Zoetelief, J .
BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (909) :638-647
[7]
Occupational radiation doses in interventional radiology: Simulations [J].
Siiskonen, T. ;
Tapiovaara, M. ;
Kosunen, A. ;
Lehtinen, M. ;
Vartiainen, E. .
RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) :36-38
[8]
Monte Carlo simulations of occupational radiation doses in interventional radiology [J].
Siiskonen, T. ;
Tapiovaara, M. ;
Kosunen, A. ;
Lehtinen, M. ;
Vartiainen, E. .
BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (954) :460-468
[9]
Snyder WS, 1978, ORNL4979