Implantable telemeter for long-term electroneurographic recordings in animals and humans

被引:30
作者
Donaldson, ND
Zhou, L
Perkins, TA
Munih, M
Haugland, M
Sinkjaer, T
机构
[1] UCL, Implanted Devices Grp, London, England
[2] Univ Ljubljana, Fac Elect Engn, Ljubljana, Slovenia
[3] Aalborg Univ, Ctr Sensory Motor Interact, Aalborg, Denmark
关键词
electroneurogram; implanted amplifier; telemeter; neuroprosthesis;
D O I
10.1007/BF02349973
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A system is described that amplifies an electroneurographic signal (ENG) from a tripolar electrode nerve cuff and transmits it from the implanted amplifier to an external drive box. The output was raw ENG, bandpass filtered from 800 to 8000Hz. The implant was powered by radio-frequency induction and operated for coil-to-coil separations up to 30mm. The testing and performance of the system is described. The input-referred noise was never more than 1muV RMS, and, at some positions of the radio-frequency field, was 0.7muV, close to the expected value for the amplifier used. The common-mode rejection ratio (CMRR) depended on the impedance imbalance from the cuff and the length of input cable. Devices with a short cable and low source impedance had CMRR of 84 dB, but, with 31 cm of cable and a real cuff the CMRR fell to 66dB. Recovery from a stimulus artifact took 5ms. The responses of the cuff to external potential gradients and to common-mode signals are described theoretically or by simulation. The devices are available for use in neuroprosthetic or neurophysiological research.
引用
收藏
页码:654 / 664
页数:11
相关论文
共 39 条
[1]  
ANDREASSEN LNS, 2000, P 5 ANN C IFESS JUN, P365
[2]   LOW-TECHNOLOGY SEALING METHOD FOR IMPLANTABLE HERMETIC PACKAGES [J].
DONALDSON, N .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (01) :111-116
[3]  
DONALDSON N, 2000, P 5 ANN C INT FUNCT, P378
[4]   ANALYSIS OF RESONANT COUPLED COILS IN THE DESIGN OF RADIO-FREQUENCY TRANS-CUTANEOUS LINKS [J].
DONALDSON, ND ;
PERKINS, TA .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1983, 21 (05) :612-627
[5]   EFFECT OF THE METALLIC SEAL OF A HERMETIC ENCLOSURE ON THE INDUCTION OF POWER TO AN IMPLANT [J].
DONALDSON, ND .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (01) :63-68
[6]   MORPHOGNOSTIC COILS - TECHNIQUE FOR TRANSMITTING SEVERAL NEARFIELD RADIO SIGNALS THROUGH THE SAME SPACE [J].
DONALDSON, NDN .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1979, 17 (02) :271-274
[7]   Speeding-up the cure of one-part silicone rubber, when encapsulating neurological prostheses: the permeable mould [J].
Donaldson, NN ;
Donaldson, PEK .
MEDICAL ENGINEERING & PHYSICS, 2000, 22 (04) :301-306
[8]   THE CRAGGS CONNECTOR - A TERMINATION FOR COOPER CABLE [J].
DONALDSON, PEK .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1985, 23 (02) :195-196
[10]   ASPECTS OF SILICONE-RUBBER AS ENCAPSULANT FOR NEUROLOGICAL PROSTHESES .2. ADHESION TO BINARY OXIDES [J].
DONALDSON, PEK ;
AYLETT, BJ .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (03) :285-292