Multi-centre evaluation of repeatability and reproducibility of the direct agglutination test for visceral leishmaniasis

被引:35
作者
Boelaert, M
El Safi, S
Mousa, H
Githure, J
Mbati, P
Gurubacharya, VL
Shrestha, J
Jacquet, D
De Muynck, A
Le Ray, D
Van der Stuyft, P
机构
[1] Inst Trop Med Prince Leopold, Dept Publ Hlth, B-2000 Antwerp, Belgium
[2] Inst Trop Med Prince Leopold, Dept Parasitol, B-2000 Antwerp, Belgium
[3] Univ Khartoum, Dept Microbiol & Parasitol, Khartoum, Sudan
[4] Kenya Med Res Inst, Nairobi, Kenya
[5] Nepal Hlth Res Council, Kathmandu, Nepal
关键词
reproducibility; direct agglutination test; visceral leishmaniasis; diagnosis; repeatability; agreement;
D O I
10.1046/j.1365-3156.1999.00348.x
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 [公共卫生与预防医学]; 120402 [社会医学与卫生事业管理];
摘要
OBJECTIVE To evaluate the repeatability and reproducibility of the serological direct agglutination test (DAT) for visceral leishmaniasis (VL) with aqueous antigen in a multi-centre study in VL-endemic areas in Sudan, Kenya and Nepal. METHODS Repeatability within each centre and reproducibility between the centres' results and an external reference laboratory (Belgium) was assessed on 1596 triplicate plain blood samples collected on filter payer. RESULTS High kappa values (range 0.86-0.97) indicated excellent DAT repeatability within the centres. The means of the titre differences between the reference laboratory and the centres in Sudan, Kenya and Nepal (2.3, 2.4 and 1.1, respectively, all significantly different from 0) showed weak reproducibility across centres. 95% of the titre differences between the reference laboratory and the respective centres were accounted for by large intervals: 0.6-9 fold titre variation for Sudan, 0.7-8 fold for Kenya and 0.26-4 fold for Nepal. CONCLUSION High repeatability of DAT confirms its potential, but reproducibility problems remain an obstacle to its routine use in the field. Reproducibility was hindered by alteration of the antigen through temperature and shaking, especially in Kenya and Sudan, and by nonstandardization of the test reading. DAT handling procedures and antigen quality must be carefully standardized and monitored when introducing this test into routine practice.
引用
收藏
页码:31 / 37
页数:7
相关论文
共 21 条
[1]
MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]
BIASES IN THE ASSESSMENT OF DIAGNOSTIC-TESTS [J].
BEGG, CB .
STATISTICS IN MEDICINE, 1987, 6 (04) :411-423
[3]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]
BOELAERT M, 1999, IN PRESS AM J TROPIC, V60
[5]
PREVALENCE OF AGGLUTINATING ANTI-LEISHMANIA ANTIBODIES IN 2 MULTI-THOUSAND BENGOLI COMMUNITIES [J].
CHOWDHURY, MS ;
ELHARITH, A ;
ALMASSUM, A ;
ALKARIM, E ;
ALRAHMAN, A .
PARASITOLOGY RESEARCH, 1993, 79 (06) :444-450
[6]
IMPROVEMENT OF A DIRECT AGGLUTINATION-TEST FOR FIELD STUDIES OF VISCERAL LEISHMANIASIS [J].
ELHARITH, A ;
KOLK, AHJ ;
LEEUWENBURG, J ;
MUIGAI, R ;
HUIGEN, E ;
JELSMA, T ;
KAGER, PA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1988, 26 (07) :1321-1325
[7]
ELHARITH A, 1987, T R SOC TROP MED HYG, V81, P603
[8]
ELHARITH AE, 1986, T ROY SOC TROP MED H, V80, P583
[10]
GRENIER B, 1998, DECISION MED, P137