In-line monitoring of granule moisture in fluidized-bed dryers using microwave resonance technology

被引:72
作者
Buschmueller, Caroline [1 ,2 ]
Wiedey, Wolfgang [2 ]
Doescher, Claas [3 ]
Dressler, Jochen [4 ]
Breitkreutz, Joerg [1 ]
机构
[1] Univ Dusseldorf, Inst Pharmaceut & Biopharmaceut, D-40225 Dusseldorf, Germany
[2] PHARBIL Waltrop GmbH, Waltrop, Germany
[3] Doscher & Doscher Ingn GmbH, Hamburg, Germany
[4] Glatt GmbH, Binzen, Germany
关键词
process analytical technology; microwave resonance technology; moisture measurement; granule water content; fluidized-bed dryer; wet granulation;
D O I
10.1016/j.ejpb.2007.09.014
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
This is the first report on in-line moisture measurement of pharmaceutical products by microwave resonance technology. In order to meet the FDA's PAT approach, a microwave resonance sensor appropriate for pharmaceutical use was developed and implemented into two different fluidized-bed dryers. The novel sensor enables a continuous moisture measurement independent from the product density. Hence, for the first time precise real time determination of the moisture in pharmaceutical granules becomes possible. The qualification of the newly developed sensor was performed by drying placebo granules under experimental conditions and the validation using drug loaded granules under real process conditions. The results of the investigations show good correlations between water content of the granules determined by the microwave resonance sensor and both reference methods, loss on drying by infrared light exposure and Karl Fischer titration. Furthermore, a considerable time saving in the drying process was achieved through monitoring the residual water content continuously by microwave resonance technology instead of the formerly used discontinuous methods. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:380 / 387
页数:8
相关论文
共 13 条
[1]  
DASCHNER F, 2006, GIT, V7, P2
[2]  
DOSCHER C, 1994, MIKROWELLEN RESONATO, P375
[3]  
DOSCHER J, 2002, PROCESS, P44
[4]  
*FDA, PROC AN TECHN IN GUI
[5]   Stray field ring resonators and a novel trough guide resonator for precise microwave moisture and density measurements [J].
Knoechel, Reinhard ;
Taute, Wolfgang ;
Doescher, Claas .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (04) :1061-1068
[6]  
Mattes R.A., 2005, SPECTROSCOPY
[7]  
MELICHAR M, 2005, P 1 EUR C LIF SCI PR, P105
[8]  
METHFESSEL J, 2006, PHARM TECHNOL EUR, V18, P24
[9]  
Prinz H, 2007, PHARM IND, V69, P223
[10]  
Rantanen J, 2001, AAPS PharmSciTech, V2, P21