Micro-CT Based Experimental Liver Imaging Using a Nanoparticulate Contrast Agent: A Longitudinal Study in Mice

被引:75
作者
Boll, Hanne [1 ]
Nittka, Stefanie [2 ]
Doyon, Fabian [3 ]
Neumaier, Michael [2 ]
Marx, Alexander [4 ]
Kramer, Martin [5 ]
Groden, Christoph [1 ]
Brockmann, Marc A. [1 ]
机构
[1] Univ Heidelberg, Dept Neuroradiol, Med Fac Mannheim, D-6800 Mannheim, Germany
[2] Univ Heidelberg, Dept Clin Chem, Med Fac Mannheim, D-6800 Mannheim, Germany
[3] Univ Heidelberg, Dept Surg, Med Fac Mannheim, D-6800 Mannheim, Germany
[4] Univ Heidelberg, Dept Pathol, Med Fac Mannheim, D-6800 Mannheim, Germany
[5] Univ Giessen, Dept Vet Clin Sci, Small Anim Clin, Giessen, Germany
关键词
COMPUTED-TOMOGRAPHY; ENHANCEMENT; TUMORS; PHEOCHROMOCYTOMA; INTUBATION; RABBITS; TIME;
D O I
10.1371/journal.pone.0025692
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
070301 [无机化学]; 070403 [天体物理学]; 070507 [自然资源与国土空间规划学]; 090105 [作物生产系统与生态工程];
摘要
Background: Micro-CT imaging of liver disease in mice relies on high soft tissue contrast to detect small lesions like liver metastases. Purpose of this study was to characterize the localization and time course of contrast enhancement of a nanoparticular alkaline earth metal-based contrast agent (VISCOVER ExiTron nano) developed for small animal liver CT imaging. Methodology: ExiTron nano 6000 and ExiTron nano 12000, formulated for liver/spleen imaging and angiography, respectively, were intravenously injected in C57BL/6J-mice. The distribution and time course of contrast enhancement were analysed by repeated micro-CT up to 6 months. Finally, mice developing liver metastases after intrasplenic injection of colon carcinoma cells underwent longitudinal micro-CT imaging after a single injection of ExiTron nano. Principal Findings: After a single injection of ExiTron nano the contrast of liver and spleen peaked after 4-8 hours, lasted up to several months and was tolerated well by all mice. In addition, strong contrast enhancement of abdominal and mediastinal lymph nodes and the adrenal glands was observed. Within the first two hours after injection, particularly ExiTron nano 12000 provided pronounced contrast for imaging of vascular structures. ExiTron nano facilitated detection of liver metastases and provided sufficient contrast for longitudinal observation of tumor development over weeks. Conclusions: The nanoparticulate contrast agents ExiTron nano 6000 and 12000 provide strong contrast of the liver, spleen, lymph nodes and adrenal glands up to weeks, hereby allowing longitudinal monitoring of pathological processes of these organs in small animals, with ExiTron nano 12000 being particularly optimized for angiography due to its very high initial vessel contrast.
引用
收藏
页数:6
相关论文
共 26 条
[1]
In-vivo high-resolution X-ray microtomography for liver and spleen tumor assessment in mice [J].
Almajdub, M. ;
Nejjari, M. ;
Poncet, G. ;
Magnier, L. ;
Chereul, E. ;
Roche, C. ;
Janier, M. .
CONTRAST MEDIA & MOLECULAR IMAGING, 2007, 2 (02) :88-93
[2]
Bakan D A, 2001, Am J Ther, V8, P359, DOI 10.1097/00045391-200109000-00009
[3]
Physicochemical characterization of a synthetic lipid emulsion for hepatocyte-selective delivery of lipophilic compounds: Application to polyiodinated triglycerides as contrast agents for computed tomography [J].
Bakan, DA ;
Longino, MA ;
Weichert, JP ;
Counsell, RE .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1996, 85 (09) :908-914
[4]
Polyiodinated triglyceride lipid emulsions for use as hepatoselective contrast agents in CT - Effects of physicochemical properties on biodistribution and imaging profiles [J].
Bakan, DA ;
Weichert, JP ;
Longino, MA ;
Counsell, RE .
INVESTIGATIVE RADIOLOGY, 2000, 35 (03) :158-169
[5]
Double-contrast micro-CT colonoscopy in live mice [J].
Boll, Hanne ;
Bag, Simona ;
Noelte, Ingo S. ;
Wilhelm, Thomas ;
Kramer, Martin ;
Groden, Christoph ;
Boecker, Ulrich ;
Brockmann, Marc A. .
INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 2011, 26 (06) :721-727
[6]
High-Speed Single-Breath-Hold Micro-Computed Tomography of Thoracic and Abdominal Structures in Mice Using a Simplified Method for Intubation [J].
Boll, Hanne ;
Bag, Simona ;
Schambach, Sebastian J. ;
Doyon, Fabian ;
Nittka, Stefanie ;
Kramer, Martin ;
Groden, Christoph ;
Brockmann, Marc A. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (05) :783-790
[7]
Comparison of Fenestra VC contrast-enhanced computed tomography imaging with gadopentetate dimeglumine and Ferucarbotran magnetic resonance imaging for the in vivo evaluation of murine liver damage after ischemia and reperfusion [J].
Chouker, Alexander ;
Lizak, Martin ;
Schimel, Daniel ;
HeImberger, Thomas ;
Ward, Jerrold M. ;
Despres, Daryl ;
Kaufmann, Ines ;
Bruns, Christiane ;
Lohe, Florian ;
Ohta, Akio ;
Sitkovsky, Michael V. ;
Klaunberg, Brenda ;
Thiel, Manfred .
INVESTIGATIVE RADIOLOGY, 2008, 43 (02) :77-91
[8]
Time-course characterization of the computed tomography contrast enhancement of an iodinated blood-pool contrast agent in mice using a volumetric flat-panel equipped computed tomography scanner [J].
Ford, NL ;
Graham, KC ;
Groom, AC ;
MacDonald, IC ;
Chambers, AF ;
Holdsworth, DW .
INVESTIGATIVE RADIOLOGY, 2006, 41 (04) :384-390
[9]
Contrast-enhanced microcomputed tomography using intraperitoneal contrast injection for the assessment of tumor-burden in liver metastasis models [J].
Graham, Kevin C. ;
Detombe, Sarah A. ;
MacKenzie, Lisa T. ;
Holdsworth, David W. ;
MacDonald, Ian C. ;
Chambers, Ann F. ;
Drangova, Maria .
INVESTIGATIVE RADIOLOGY, 2008, 43 (07) :488-495
[10]
Evaluation of a Continuous-Rotation, High-Speed Scanning Protocol for Micro-Computed Tomography [J].
Kerl, Hans Ulrich ;
Isaza, Cristina T. ;
Boll, Hanne ;
Schambach, Sebastian J. ;
Nolte, Ingo S. ;
Groden, Christoph ;
Brockmann, Marc A. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (04) :517-523