Backwash of RO spiral wound membranes

被引:80
作者
Sagiv, A [1 ]
Semiat, R [1 ]
机构
[1] Technion Israel Inst Technol, Grand Water Res Inst, Dept Chem Engn, Rabin Desalinat Lab, IL-32000 Haifa, Israel
关键词
desalination; backwash; cleaning; reverse osmosis; osmotic backwash;
D O I
10.1016/j.desal.2004.11.050
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Osmotic backwash experiments were conducted and analytical model was developed in attempt to describe the backwash mechanism. A single unit of a spiral wound RO membrane was used in the experiments. The RO membrane was fed by salted water solution. Permeate flux characteristics of the membrane were determined through steady-state RO experiments. Then the system was shifted immediately to a backwash process by reducing the feed pressure, Delta p, either to zero or to a level below the osmotic pressure to allow net backwash driving force. The backwash experiments reveal that the backwash process has two distinct regions. The flow rate drops sharply at the initial backwash process, followed by a prominently slower flow rate continuously slows down until it reaches a constant value (toward zero, for Delta p = 0). These results suggest that the first backwash stage acts mainly to dilute the salt concentration at the feed concentration polarization (CP) layer. The second stage of the backwash flow rate exhibits salt dilution of the bulk solution. RO experiments were conducted also with a super-saturated CaCO3 solution, to cause salt precipitation and partially clogging of the membrane surface followed by flux reduction. The permeate flux was resumed to its original level with osmotic backwash cleaning of the membrane. Effects of three independent RO feed variables; feed concentration, flow rate, and applied pressure, on the accumulated volume of backwash water, v(t) were analyzed experimentally. It was found that feed concentration has the strongest effect on v(t), while the other two parameters has only minor effects on the process. Presence of operational pressure during the backwash process reduces v(t) dramatically, as a consequence of the driving force reduction. A simple analytical model was developed and fits well the experimental data of the second stage without feed flow during the backwash process.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 15 条
[1]  
Ando M., 2002, Running method and treatment system for spiral wound membrane element and spiral wound membrane module, EP 1170053 A1 20020109, Patent No. 1170053
[2]  
Ando M., 2003, Treatment system having spiral membrane element and method for operating the treatment system, EP 1323461 A2 20030703, Patent No. 1323461
[3]   Optimization of membrane physical and chemical cleaning by a statistically designed approach [J].
Chen, JP ;
Kim, SL ;
Ting, Y .
JOURNAL OF MEMBRANE SCIENCE, 2003, 219 (1-2) :27-45
[4]  
Fukunaga Koh-Ichi, 1997, Membrane, V22, P211
[5]   Fouling characteristics of NF and RO operated for removal of dissolved matter from groundwater [J].
Gwon, EM ;
Yu, MJ ;
Oh, HK ;
Ylee, YH .
WATER RESEARCH, 2003, 37 (12) :2989-2997
[6]   Operation of NF/RO plants: from reactive to proactive [J].
Huiting, H ;
Kappelhof, JWNM ;
Bosklopper, TGJ .
DESALINATION, 2001, 139 (1-3) :183-189
[7]  
ISAO S, 2002, Patent No. 200203556
[8]  
KOJI H, 2001, Patent No. 2001286886
[9]  
LIBERMAN B, 2004, IDA WORKSH TEMP SAN
[10]   Chemical cleaning of reverse osmosis membranes fouled by whey [J].
Madaeni, SS ;
Mansourpanah, Y .
DESALINATION, 2004, 161 (01) :13-24