Experimental analysis of overall thermal properties of parabolic trough receivers

被引:43
作者
Luepfert, Eckhard [1 ]
Riffelmann, Klaus-J. [2 ]
Price, Henry [3 ]
Burkholder, Frank [3 ]
Moss, Tim [4 ]
机构
[1] German Aerosp Ctr DLR, Inst Tech Thermodynam, D-51170 Cologne, Germany
[2] Flagsol GmbH, Cologne, Germany
[3] Natl Renewable Energy Lab, Golden, CO 80401 USA
[4] Sandia Natl Labs, Albuquerque, NM 87185 USA
来源
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME | 2008年 / 130卷 / 02期
关键词
parabolic trough; absorber; thermal losses; thermal testing;
D O I
10.1115/1.2888756
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The heat loss of a receiver in a parabolic trough collector plays an important role in collector performance. A number of methods have been used to measure the thermal loss of a receiver tube depending on its operating temperature. This paper presents methods for measuring receiver heat losses including field measurements and laboratory setups both based on energy balances from the hot inside of the receiver tube to the ambient. Further approaches are presented to measure and analyze the temperature of the glass envelope of evacuated receivers and to model overall heat losses and emissivity coefficients of the receiver Good agreement can be found between very different approaches and independent installations. For solar parabolic trough plants operating in the usual 390 degrees C temperature range, the thermal loss is around 300 W/m receiver length.
引用
收藏
页码:0210071 / 0210075
页数:5
相关论文
共 7 条
[1]  
BURKHOLDER F, 2007, P ASME 2007 LONG BEA
[2]  
Duffle J.A., 1991, SOLAR ENG THERMAL PR
[3]  
LUPFERT E, 2007, ASME, V129, P147
[4]  
LUPFERT E, 2006, 13 INT S CONC SOL TE
[5]  
MOSS T, 2005, 76022 ASME ISEC
[6]   Pyrometric temperature measurements on solar thermal high temperature receivers [J].
Pfaender, Markus ;
Luepfert, Eckhard ;
Heller, Peter .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (03) :285-292
[7]  
PRICE H, 2006, ASME ISEC 0708