Optimized multilayer oxalate biosensor

被引:62
作者
Fiorito, PA [1 ]
de Torresi, SIC [1 ]
机构
[1] Univ Sao Paulo, Inst Quim, BR-05513970 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
amperometric biossensor; oxalate detection; conducting polymers;
D O I
10.1016/j.talanta.2003.09.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The optimization of a biosensor prepared by the immobilization of oxalate oxidase (OOX) with a cross-linking agent onto a multilayer inorganic/organic modified electrode, is presented. A very thin Prussian Blue (PB) film covered by a self-doped polyaniline (SPAN) layer acts as very sensitive amperometric sensor for the H2O2 formed by the enzymatic reaction. The electrode allows the very reliable and sensitive oxalate detection in the 0.08 to 0.45 mmol l(-1) concentration range. The observed sensitivity was 131.3 muA mmol(-1) cm(-2) at the operation potential of 0.05 V versus Ag/AgCl in a succinate buffer solution (pH = 3.8). The bilayer Prussian blue/SPAN leads to a very stable, sensitive and selective system that not only minimizes the interference caused by ascorbic and uric acids but also forms a very adherent sensing film that allows repetitive successive determinations. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:649 / 654
页数:6
相关论文
共 18 条
[1]   Oxidative degradation of the ascorbate anion in the presence of platinum and palladium. Formation and structures of platinum and palladium oxalate complexes [J].
Arendse, MJ ;
Anderson, GK ;
Rath, NP .
POLYHEDRON, 2001, 20 (19) :2495-2503
[2]  
De Mattos IL, 2001, QUIM NOVA, p200e5
[3]   Determination of oxalate in grass by FIA with a spectrophotometric detection system using a two enzyme reactor [J].
Fernandes, JR ;
Neto, GD ;
Tubino, M ;
Kubota, LT .
ANALYTICAL SCIENCES, 1996, 12 (03) :443-447
[4]   Use of sorghum seed tissue as a biocatalyst in a stirred reactor for oxalic acid determination [J].
Fernandes, JR ;
Neto, CD ;
Kubota, LT ;
Tubino, M .
ANALYTICAL COMMUNICATIONS, 1996, 33 (11) :397-399
[5]  
FRANCE NC, 1985, J CHROMATOGR, V433, P1
[6]   THE DETERMINATION OF OXALATE IN URINE AND PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FRY, IDR ;
STARKEY, BJ .
ANNALS OF CLINICAL BIOCHEMISTRY, 1991, 28 :581-587
[7]  
GRAJONYTE R, 1998, SENSOR ACTUAT B-CHEM, V46, P236
[8]   IMPROVED COLORIMETRIC PROCEDURE FOR URINE OXALATE [J].
HODGKINSON, A ;
WILLIAMS, A .
CLINICA CHIMICA ACTA, 1972, 36 (01) :127-+
[9]   Ellipsometric, electrogravimetric, and spectroelectrochemical studies of the redox process of sulfonated polyaniline [J].
Mello, RMQ ;
Torresi, RM ;
de Torresi, SIC ;
Ticianelli, EA .
LANGMUIR, 2000, 16 (20) :7835-7841
[10]  
Milardovic S, 2000, J AOAC INT, V83, P1212