Determination of benzophenones in human placental tissue samples by liquid chromatography-tandem mass spectrometry

被引:69
作者
Vela-Soria, F. [1 ]
Jimenez-Diaz, I. [1 ,2 ]
Rodriguez-Gomez, R. [1 ]
Zafra-Gomez, A. [1 ]
Ballesteros, O. [1 ]
Navalon, A. [1 ]
Vilchez, J. L. [1 ]
Fernandez, M. F. [2 ]
Olea, N. [2 ]
机构
[1] Univ Granada, Res Grp Analyt Chem & Life Sci, Dept Analyt Chem, E-18071 Granada, Spain
[2] Univ Granada, Lab Med Invest, San Cecilia Univ Hospital, CIBER Epidemiol & Publ Hlth CIBERESP, E-18071 Granada, Spain
关键词
Benzophenone; Liquid chromatography-tandem mass spectrometry (LC-MS/MS); Human placental tissue analysis; HPLC-MS/MS METHOD; SOLID-PHASE MICROEXTRACTION; PERSONAL CARE PRODUCTS; HUMAN URINE SAMPLES; UV FILTERS; IN-VIVO; ENVIRONMENTAL PHENOLS; WASTE-WATER; SENSITIVE DETERMINATION; ESTROGENIC ACTIVITY;
D O I
10.1016/j.talanta.2011.07.030
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
Benzophenones (BPS) are a family of compounds widely used to protect the skin and hair from UV irradiation. Despite human exposure to BPs through dermal application of products containing sunscreen agents and the increasing evidence that BPs are able to interfere with endocrine systems, few studies have examined the occurrence of BPs in humans. In this work, we propose a new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to determine six BPs, namely. benzophenone-1 (BP-1), benzophenone-2 (BP-2), benzophenone-3 (BP-3). benzophenone-6 (BP-6), benzophenone-8 (BP-8) and 4-hydroxybenzophenone (4-0H-BP) in human placental tissue samples. The method involves an extraction step of the analytes from the samples using ethyl acetate, followed by a clean-up step using centrifugation prior to their quantification by LC-MS/MS using an atmospheric pressure chemical ionization (APCI) interface in the positive mode. Benzophenone-d(10) (BR-d(10)) was used as surrogate. Found detection limits (LOD) ranged from 0.07 to 0.3 ngg(-1) and quantification limits (LOQ) from 0.3 to 1.0 ngg(-1), while inter- and intra-day variability was under 5%. The method was validated using standard addition calibration and a recovery assay. Recovery rates for spiked samples ranged from 98 to 104%. This method was satisfactorily applied for the determination of BPs in 16 placental tissue samples collected from women who live in Granada (Spain). (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1848 / 1855
页数:8
相关论文
共 46 条
[1]
[Anonymous], 1982, STATGR CENTURION 15
[2]
[Anonymous], 1976, OFF J EUR COMMUN L, V262, P169
[3]
Occurrence of some organic UV filters in wastewater, in surface waters, and in fish from Swiss lakes [J].
Balmer, ME ;
Buser, HR ;
Müller, MD ;
Poiger, T .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (04) :953-962
[4]
Occurrence of UV filters 4-methylbenzylidene camphor and octocrylene in fish from various swiss rivers with inputs from wastewater treatment plants [J].
Buser, HR ;
Balmer, ME ;
Schmid, P ;
Kohler, M .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2006, 40 (05) :1427-1431
[5]
Estimate of gas chromatographic blanks - Application to detection limits evaluation as recommended by IUPAC [J].
Casado, AG ;
Rodriguez, LC ;
Hernandez, EA ;
Vilchez, JL .
JOURNAL OF CHROMATOGRAPHY A, 1996, 726 (1-2) :133-139
[6]
Determination of UV filters and antimicrobial agents in environmental water samples [J].
Cuderman, Petra ;
Heath, Ester .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (04) :1343-1350
[7]
Nomenclature in evaluation of analytical methods including detection and quantification capabilities (IUPAC Recommendations 1995) [J].
Currie, LA .
ANALYTICA CHIMICA ACTA, 1999, 391 (02) :105-126
[8]
Determination of benzophenone-3 and metabolites in water and human urine by solid-phase microextraction and quadrupole ion trap GC-MS [J].
Felix, T ;
Hall, BJ ;
Brodbelt, JS .
ANALYTICA CHIMICA ACTA, 1998, 371 (2-3) :195-203
[9]
ABSORPTION OF SUNSCREENS AND OTHER COMPOUNDS THROUGH HUMAN SKIN IN-VIVO - DERIVATION OF A METHOD TO PREDICT MAXIMUM FLUXES [J].
HAGEDORNLEWEKE, U ;
LIPPOLD, BC .
PHARMACEUTICAL RESEARCH, 1995, 12 (09) :1354-1360
[10]
Systemic absorption of sunscreen after topical application [J].
Hayden, CGJ ;
Roberts, MS ;
Benson, HAE .
LANCET, 1997, 350 (9081) :863-864