Study of axis-shield new %CDT immunoassay for quantification of carbohydrate-deficient transferrin (CDT) in serum

被引:69
作者
Helander, A
Fors, M
Zakrisson, B
机构
[1] Karolinska Hosp, Alcohol Lab, Div Clin Chem, SE-17176 Stockholm, Sweden
[2] Karolinska Inst, Dept Clin Neurosci, Stockholm, Sweden
来源
ALCOHOL AND ALCOHOLISM | 2001年 / 36卷 / 05期
关键词
D O I
10.1093/alcalc/36.5.406
中图分类号
R194 [卫生标准、卫生检查、医药管理];
学科分类号
摘要
Carbohydrate-deficient transferrin (CDT) in serum has emerged as a useful biochemical marker for identifying current alcohol misuse and monitoring abstinence. This study evaluated the performance of Axis-Shield new %CDT turbidimetric immunoassay (TIA; microtitre and Cobas Mira applications). Comparison was made with the previous Axis %CDT-TIA immunoassay (reference value <5.5%) and %CDT with the high-performance liquid chromatography (HPLC) technique (reference value <1.2%). The new %CDT assay measures primarily the asialo, monosialo and disialo transferrin isoforms, and the result is expressed as the amount relative to total transferrin. The analytical precision (coefficient of variation: CV) of the %CDT assay ranged between 3.1 and 8.5% for kit controls and serum samples. The %CDT values in serum from healthy social drinkers [i.e. Alcohol Use Disorders Identification Test (AUDIT) score 1-7 for men, and 1-5 for women] were 2.07 +/- 0.37% (mean +/- SD, range 1.4-3.3%, n = 100) and this was not significantly different from healthy non-drinkers (1.88 +/- 0.43%, 1.3-2.9%, n = 14), whereas abstinent alcohol patients showed slightly higher values (2.26 +/- 0.41, 1.7-3.4, n = 25). In chronic heavy drinkers (mean daily intake 225 +/- 137 g ethanol according to self-report), the %CDT values were markedly increased (6.33 +/- 4.01%, 1.2-18.0%, n = 107). There was no significant difference in %CDT values between male and female social drinkers. The reference value of the new %CDT assay to be used in clinical practice was tentatively set at <3.0%, which is slightly higher than that obtained by receiver operating characteristics (ROC) curve analysis (<2.8%) and that proposed by the manufacturer in the Instruction Manual (<2.6%). The %CDT assay showed good overall correlation with %CDT-TIA (r = 0.986, P < 0.0001) and %CDT-HPLC (r = 0.978, P < 0.0001). The specificity of the %CDT assay in healthy social drinkers was 98% (%CDT-TIA 100%, %CDT-HPLC 99%) and the sensitivity for any drinking during last week in the alcohol patients was 75% (%CDT-TIA 71%, %CDT-HPLC 80%). The new Axis-Shield %CDT assay can be recommended for routine use. However, whenever a positive immunoassay test result could lead to serious consequences for the individual, it is recommended to confirm the CDT result by the HPLC technique.
引用
收藏
页码:406 / 412
页数:7
相关论文
共 28 条
[1]   CARBOHYDRATE-DEFICIENT TRANSFERRIN AS A MEASURE OF IMMODERATE DRINKING - REMAINING ISSUES [J].
ALLEN, JP ;
LITTEN, RZ ;
ANTON, RF ;
CROSS, GM .
ALCOHOLISM-CLINICAL AND EXPERIMENTAL RESEARCH, 1994, 18 (04) :799-812
[2]   CARBOHYDRATE-DEFICIENT TRANSFERRIN AND GAMMA-GLUTAMYL-TRANSFERASE AS MARKERS OF HEAVY ALCOHOL-CONSUMPTION - GENDER DIFFERENCES [J].
ANTON, RF ;
MOAK, DH .
ALCOHOLISM-CLINICAL AND EXPERIMENTAL RESEARCH, 1994, 18 (03) :747-754
[3]  
Bean P, 1997, CLIN CHEM, V43, P983
[4]  
Helander A, 2001, Lakartidningen, V98, P5554
[5]  
Dibbelt L, 2000, CLIN CHEM, V46, P1203
[6]  
Heggli DE, 1996, ALCOHOL ALCOHOLISM, V31, P381
[7]  
Helander A, 1999, CLIN CHEM, V45, P131
[8]   Comparison of urinary 5-hydroxytryptophol, breath ethanol, and self-report for detection of recent alcohol use during outpatient treatment: a study on methadone patients [J].
Helander, A ;
von Wachenfeldt, J ;
Hiltunen, A ;
Beck, O ;
Liljeberg, P ;
Borg, S .
DRUG AND ALCOHOL DEPENDENCE, 1999, 56 (01) :33-38
[9]  
Helander A, 2001, CLIN CHEM, V47, P1225
[10]   Carbohydrate-deficient transferrin and gamma-glutamyl transferase levels during disulfiram therapy [J].
Helander, A ;
Carlsson, S .
ALCOHOLISM-CLINICAL AND EXPERIMENTAL RESEARCH, 1996, 20 (07) :1202-1205