Optimum insulation thicknesses for building walls with respect to cooling and heating degree-hours in the warmest zone of Turkey

被引:231
作者
Bolatturk, Ali [1 ]
机构
[1] Suleyman Demirel Univ, Dept Mech Engn, TR-32260 Isparta, Turkey
关键词
thermal insulation; optimum insulation thickness; cooling degree-hours; heating degree-hours; energy savings;
D O I
10.1016/j.buildenv.2007.02.014
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Thermal insulation is one of the most effective energy conservation measures for cooling and heating in buildings. Therefore, determining and selecting the optimum thickness of insulation is the main subject of many engineering investigations. In this study, the determination of optimum insulation thickness on external walls of buildings is comparatively analyzed based on annual heating and cooling loads. The transmission loads, calculated by using measured long-term meteorological data for selected cities, are fed into an economic model (P-1-P-2 method) in order to determine the optimum insulation thickness. The degree-hours method that is the simplest and most intuitive way of estimating the annual energy consumption of a building is used in this study. The results show that the use of insulation in building walls with respect to cooling degree-hours is more significant for energy savings compared to heating degree-hours in Turkey's warmest zone. The optimum insulation thickness varies between 3.2 and 3.8 cm; the energy savings varies between 8.47 and 12.19 $/m(2); and the payback period varies between 3.39 and 3.81 years depending on the cooling degree-hours. On the other hand, for heating load, insulation thickness varies between 1.6 and 2.7 cm, energy savings varies between 2.2 and 6.6 $/m(2) and payback periods vary between 4.15 and 5.47 years. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1055 / 1064
页数:10
相关论文
共 26 条
[1]   Determination and selecting the optimum thickness of insulation for buildings in hot countries by accounting for solar radiation [J].
Al-Khawaja, MJ .
APPLIED THERMAL ENGINEERING, 2004, 24 (17-18) :2601-2610
[2]  
Al-Sanea S.A., 2002, Int. J. Ambient. Energy, V23, P115, DOI [10.1080/01430750.2002.9674880, DOI 10.1080/01430750.2002.9674880]
[3]   COOLING LOAD RESPONSE FOR BUILDING WALLS COMPRISING HEAT STORING AND THERMAL INSULATING LAYERS [J].
ALTURKI, A ;
ZAKI, GM .
ENERGY CONVERSION AND MANAGEMENT, 1991, 32 (03) :235-247
[4]  
ASANEA SA, 2002, INT J AMBIENT ENERGY, V23, P115
[5]  
ASHRAE, 1993, HDB FUND
[6]   Degree-days, degree-hours and ambient temperature bin data from monthly-average temperatures (Romania) [J].
Badescu, V ;
Zamfir, E .
ENERGY CONVERSION AND MANAGEMENT, 1999, 40 (08) :885-900
[7]   Insulation protection studies for energy saving in residential and tertiary sector [J].
Bakos, GC .
ENERGY AND BUILDINGS, 2000, 31 (03) :251-259
[8]   Determination of optimum insulation thickness for building walls with respect to various fuels and climate zones in Turkey [J].
Bolatturk, A .
APPLIED THERMAL ENGINEERING, 2006, 26 (11-12) :1301-1309
[9]   Analysis of variable-base heating and cooling degree-days for Turkey [J].
Büyükalaca, O ;
Bulut, H ;
Yilmaz, T .
APPLIED ENERGY, 2001, 69 (04) :269-283
[10]  
Cengel YA., 1998, HEAT TRANSFER PRACTI