A 768-lane microfabricated system for high-throughput DNA sequencing

被引:55
作者
Aborn, JH [1 ]
El-Difrawy, SA [1 ]
Novotny, M [1 ]
Gismondi, EA [1 ]
Lam, R [1 ]
Matsudaira, P [1 ]
Mckenna, BK [1 ]
O'Neil, T [1 ]
Streechon, P [1 ]
Ehrlich, DJ [1 ]
机构
[1] Whitehead Inst Biomed Res, Cambridge, MA 02142 USA
关键词
D O I
10.1039/b501104c
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A 768-lane DNA sequencing system based on microfluidic plates has been designed as a near-term successor to 96-lane capillary arrays. Electrophoretic separations are implemented for the first time in large-format ( 25 cm x 50 cm) microdevices, with the objective of proving realistic read length, parallelism, and the scaled sample requirements for long-read de novo sequencing. Two 384-lane plates are alternatively cycled between electrophoresis and regeneration via a robotic pipettor. A total of greater than 172 000 bases, 99% accuracy ( corresponding to quality score 20) is achieved for each iteration of a 384 lane plate. At current operating conditions, this implies a system throughput exceeding 4 megabases of raw sequence (Phred 20) per day on the new platform. Standard operation is at "1/32 x'' Sanger chemistry, equal to typical genome center operation on mature capillary array machines, and a 16-fold improvement in scaling relative to previous microfabricated devices. Experiments provide evidence that sample concentration can be further reduced to 1/256 x Sanger chemistry in the microdevice. Life-testing indicates a usable life of >150 hours ( more than 50 runs) for the 384 lane plates. The combined advances, particularly those in read length and sample requirement, directly address the cost model requirements for adaptation of the new technology as the next step beyond capillary array instruments.
引用
收藏
页码:669 / 674
页数:6
相关论文
共 14 条
  • [1] Drmanac R, 2001, Methods Mol Biol, V170, P173
  • [2] El-Difrawy S, 2004, PROCEEDINGS OF THE IEEE 30TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, P112
  • [3] ELDIFRAWY S, REV SCI INSTR
  • [4] Base-calling of automated sequencer traces using phred.: II.: Error probabilities
    Ewing, B
    Green, P
    [J]. GENOME RESEARCH, 1998, 8 (03): : 186 - 194
  • [5] Long-read pyrosequencing using pure 2′-deoxyadenosine-5′-O′-(1-thiotriphosphate) Sp-isomer
    Gharizadeh, B
    Nordström, T
    Ahmadian, A
    Ronaghi, M
    Nyrén, P
    [J]. ANALYTICAL BIOCHEMISTRY, 2002, 301 (01) : 82 - 90
  • [6] Eight hundred base sequencing in a microfabricated electrophoretic device
    Koutny, L
    Schmalzing, D
    Salas-Solano, O
    El-Difrawy, S
    Adourian, A
    Buonocore, S
    Abbey, K
    McEwan, P
    Matsudaira, P
    Ehrlich, D
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (14) : 3388 - 3391
  • [7] DNA molecules and configurations in a solid-state nanopore microscope
    Li, JL
    Gershow, M
    Stein, D
    Brandin, E
    Golovchenko, JA
    [J]. NATURE MATERIALS, 2003, 2 (09) : 611 - 615
  • [8] LIPSHUTZ RJ, 1995, BIOTECHNIQUES, V19, P442
  • [9] Automated parallel DNA sequencing on multiple channel microchips
    Liu, SR
    Ren, HJ
    Gao, QF
    Roach, DJ
    Loder, RT
    Armstrong, TM
    Mao, QL
    Blaga, I
    Barker, DL
    Jovanovich, SB
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (10) : 5369 - 5374
  • [10] Meldrum DR, 2000, GENOME RES, V10, P95