Conversion of umbilical arterial Doppler waveforms to cardiac cycle triggering signals: A preparatory study for online motion-gated three-dimensional fetal echocardiography

被引:17
作者
Deng, J
Birkett, AG
Kalache, KD
Hanson, MA
Peebles, DM
Linney, AD
Lees, WR
Rodeck, CH
机构
[1] UCL, Dept Obstet & Gynaecol, London, England
[2] UCL, Dept Med Phys & Bioengn, London, England
[3] UCL, Dept Med Imaging, London, England
基金
英国惠康基金;
关键词
fetal heart; ultrasonography; Doppler and echocardiography; three-dimensional; four-dimensional; motion artefact; cardiac gating; ultrasound interference; scanner design; transit-time ultrasound flow meter; electrocardiography;
D O I
10.1016/S0301-5629(00)00315-X
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
To remove motion artefacts, a device was built to convert "noisy" umbilical arterial Doppler waveforms (UADWs) from an ultrasound (US) system into sharp ECG R-wave-like cardiac cycle triggering signals (CCTSs). These CCTSs were then used to gate a simultaneous (online) 3-D acquisition of sectional fetal echocardiograms from another US system. To test the conversion performance, a study was carried out in sheep fetal twins. Pulmonary arterial flow waveforms (PAFWs) from implanted probes were traced, in the meantime, to determine the reference cardiac cycle. Interference caused by running the two nonsynchronised US systems was controlled to three degrees (not-noticeable, moderate, and severe), together with high (greater than or equal to 40 cm/s) and low (< 40) flow velocities on UADWs. The conversion efficiency, assessed by the percentage of UADWs converted into CCTSs, was in the range of 83% to 100% for not-noticeable and moderate interference, and 0% to 71% for severe interference. The triggering accuracy, assessed by [(time lag mean between the onsets of PAFWs and corresponding CCTSs) - (its 99% confidence level)] <divided by> the mean, was 90% to 96% for the not-noticeable interference high- and low-flow groups and for the moderate interference high-how group; 19% to 93% for the moderate interference low-flow group; and from not obtainable up to 90% for the severe interference groups. The results show that UADWs can be used as a satisfactory online motion-gating source even in the presence of moderate interference. The major problems are from severe interference or moderate interference with low-flow velocity, which can be minimised/eliminated by the integration of the individual systems involved. (E-mail: jdeng@medphys.ucl.ac.uk) (C) 2001 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:51 / 59
页数:9
相关论文
共 11 条
[1]   Validation study of a new transit time ultrasonic flow probe for continuous great vessel measurements [J].
Dean, DA ;
Jia, CX ;
Cabreriza, SE ;
DAlessandro, DA ;
Dickstein, ML ;
Sardo, MJ ;
Chalik, N ;
Spotnitz, HM .
ASAIO JOURNAL, 1996, 42 (05) :M671-M676
[2]   Fetal echocardiography in three and four dimensions [J].
Deng, J ;
Gardener, JE ;
Rodeck, CH ;
Lees, WR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (08) :979-986
[3]   Online motion-gated dynamic three-dimensional echocardiography in the fetus - Preliminary results [J].
Deng, J ;
Yates, R ;
Birkett, AG ;
Ruff, CF ;
Linney, AD ;
Lees, WR ;
Hanson, MA ;
Rodeck, CH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (01) :43-50
[4]   Simultaneous use of two ultrasound scanners for motion-gated three-dimensional fetal echocardiography [J].
Deng, J ;
Ruff, CF ;
Linney, AD ;
Lees, WR ;
Hanson, MA ;
Rodeck, CH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (06) :1021-1032
[5]   AFFERENT AND EFFERENT COMPONENTS OF THE CARDIOVASCULAR REFLEX RESPONSES TO ACUTE-HYPOXIA IN TERM FETAL SHEEP [J].
GIUSSANI, DA ;
SPENCER, JAD ;
MOORE, PJ ;
BENNET, L ;
HANSON, MA .
JOURNAL OF PHYSIOLOGY-LONDON, 1993, 461 :431-449
[6]  
KWON J, 1996, J AM SOC ECHOCARDIOG, V9, P389
[7]  
Nelson TR, 1996, J ULTRAS MED, V15, P1
[8]   SIMULATION OF INTRAOPERATIVE VISUALIZATION OF CARDIAC STRUCTURES AND STUDY OF DYNAMIC SURGICAL ANATOMY WITH REAL-TIME 3-DIMENSIONAL ECHOCARDIOGRAPHY [J].
SCHWARTZ, SL ;
CAO, QL ;
AZEVEDO, J ;
PANDIAN, NG .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 73 (07) :501-507
[9]  
Sklansky MS, 1999, J ULTRAS MED, V18, P745
[10]   ASSESSMENT OF CONGENITAL HEART-DEFECTS BY DYNAMIC 3-DIMENSIONAL ECHOCARDIOGRAPHY - METHODS OF DATA-ACQUISITION AND CLINICAL POTENTIAL [J].
VOGEL, M ;
HO, SY ;
BUHLMEYER, K ;
ANDERSON, RH .
ACTA PAEDIATRICA, 1995, 84 :34-39