Treatment of periprosthetic femur fractures with the non-contact bridging plate: a new angular stable implant

被引:94
作者
Erhardt, J. B. [1 ]
Grob, K. [1 ]
Roderer, G. [2 ]
Hoffmann, A. [1 ]
Forster, T. N. [1 ]
Kuster, M. S. [1 ]
机构
[1] Kantonsspital, Orthopad Chirurg Klin, CH-9007 St Gallen, Switzerland
[2] Univ Western Australia, Fremantle Orthopaed Unit, Perth, WA 6009, Australia
关键词
NCB; periprosthetic fracture; non contact bridging; polyaxial locked plate;
D O I
10.1007/s00402-007-0396-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives We report the application of a new fixed angle plate (NCB DF (R), Zimmer inc. USA, Warsaw, IN) in the treatment of periprosthetic femur fractures. The NCB DF (R) combines conventional plating technique with polyaxial screw placement and angular stability. Design Prospective cohort study. Setting A single level-1 trauma center. Patients From May 2003 to December 2005, a total of 24 patients with periprosthetic femur fractures were treated. The NCB DF (R) femur plate was used in all cases. The average follow-up period was 12 months (3-31 months). Twelve patients had a periprosthetic fracture after total knee replacement (TKA) and 12 patients after total hip replacement (THA). The mean period from primary joint replacement to periprosthetic fracture was 8.2 years for the THA group and 7.2 years for the TKA group. Intervention A combined conventional/locking surgical technique was performed in all the cases. Main outcome measures Union, non-union, mal-union, duration of surgery, range of motion, postoperative mobility, subjective patient satisfaction and complications. Results The union rate was 90%, the mal-union rate 5% and the re-operation rate 15%. Postoperative mobility reached the preoperative level in all but for two patients. Three complications occurred relating to the implant or the procedure: one fatigue failure of the plate (non-union), one screw breakage, and one wound infection. Conclusions The NCB DF (R) combines conventional plating technique with polyaxial screw placement and angular stability. This combination technique shows promising results regarding union and mal-union rates in periprosthetic fractures in elderly and osteoporotic patients.
引用
收藏
页码:409 / 416
页数:8
相关论文
共 22 条
[1]
Operative stabilization of supracondylar femur fractures above total knee arthroplasty - A comparison of four treatment methods [J].
Althausen, PL ;
Lee, MA ;
Finkemeier, CG ;
Meehan, JP ;
Rodrigo, JJ .
JOURNAL OF ARTHROPLASTY, 2003, 18 (07) :834-839
[2]
Aro HT, 1993, CLIN ORTHOP RELAT R, V293, P8
[3]
Beals R, 1996, CLIN ORTHOP RELAT R, V327, P238, DOI DOI 10.1097/00003086-199606000-00029
[4]
Epidemiology - Hip and knee [J].
Berry, DJ .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (02) :183-+
[5]
Comparison of the LISS and a retrograde-inserted supracondylar intramedullary nail for fixation of a periprosthetic distal femur fracture proximal to a total knee arthroplasty [J].
Bong, MR ;
Egol, KA ;
Koval, KJ ;
Kummer, FJ ;
Su, ET ;
Iesaka, K ;
Bayer, J ;
Di Cesare, PE .
JOURNAL OF ARTHROPLASTY, 2002, 17 (07) :876-881
[6]
Classification of the hip [J].
Brady, OH ;
Garbuz, DS ;
Masri, BA ;
Duncan, CP .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (02) :215-+
[7]
Chen F, 1994, J Arthroplasty, V9, P521, DOI 10.1016/0883-5403(94)90099-X
[8]
CULP RW, 1987, CLIN ORTHOP RELAT R, V222, P212
[9]
Davison Brian L, 2003, Am J Orthop (Belle Mead NJ), V32, P27
[10]
Figgie M P, 1990, J Arthroplasty, V5, P267, DOI 10.1016/S0883-5403(08)80082-4