Real-Time Implementation of a Hybrid Protection Scheme for Bipolar HVDC Line Using FPGA

被引:91
作者
Liu, Xiaolei [1 ]
Osman, Ahmed H. [2 ]
Malik, Om P. [1 ]
机构
[1] Univ Calgary, Calgary, AB T2N 1N4, Canada
[2] Amer Univ Sharjah, Dept Elect Engn, Sharjah, U Arab Emirates
关键词
Boundary protection; field-programmable gate array (FPGA) implementation; HVDC line protection; real-time implementation; relay; stationary wavelet transform; traveling waves; WAVELET-TRANSFORM; FAULT LOCATOR; TRANSMISSION;
D O I
10.1109/TPWRD.2010.2056394
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
080906 [电磁信息功能材料与结构]; 082806 [农业信息与电气工程];
摘要
A hybrid protection scheme for bipolar HVDC line has been implemented with field-programmable gate array (FPGA) and evaluation of its performance in real time is described in this paper. The protection scheme amalgamates a traveling wave protection unit, a boundary protection unit, and a lightning unit. A stationary wavelet transform (SWT) and its wavelet modulus maxima are used to remove noise and represent a useful traveling wave signal. Boundary protection based on SWT is used jointly with traveling wave protection to distinguish internal faults from external faults. The lightning unit is used to distinguish non-fault transients and to identify the faulty pole. Xilinx XtremeDSP Development Kit-4 is employed for the hardware implementation, with coding done using the Xilinx System Generator and AccelDSP. The cost-efficient hardware co-simulation approach is adopted here to evaluate the real-time performance of the protection scheme.
引用
收藏
页码:101 / 108
页数:8
相关论文
共 23 条
[1]
ABB, 2007, DIG OPT INSTR TRANSF
[2]
Anderson P.M., 1999, POWER SYSTEM PROTECT, P915
[3]
DEVELOPMENT AND FIELD-DATA EVALUATION OF SINGLE-END FAULT LOCATOR FOR 2-TERMINAL HVDC TRANSMISSION-LINES .1. DATA-COLLECTION SYSTEM AND FIELD DATA [J].
ANDO, M ;
SCHWEITZER, EO ;
BAKER, RA .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (12) :3524-3530
[4]
[Anonymous], 2008, ACCELDSP SYNTH TOOL
[5]
[Anonymous], 2009, NATL INSTRUMENT SUPP
[6]
Modeling of bipolar HVdc links in the harmonic domain [J].
Bathurst, GN ;
Watson, NR ;
Arrillaga, J .
IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (03) :1034-1038
[7]
A new non-communication protection technique for transmission lines [J].
Bo, ZQ .
IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (04) :1073-1078
[8]
Surge impedance relay [J].
Dong, XZ ;
Ge, YZ ;
He, JL .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) :1247-1256
[9]
Gale PF, 2001, IEE CONF PUBL, P327, DOI 10.1049/cp:20010166
[10]
TRANSIENT OVERVOLTAGE ON A BIPOLAR HVDC OVERHEAD LINE CAUSED BY DC LINE FAULTS [J].
HINGORANI, NG .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1970, PA89 (04) :592-+