A carbon paste modified with silica gel coated with Meldola's Blue and fructose 5-dehydrogenase was used to construct a new biosensor for fructose. An efficient electron transfer mediation from the reduced enzyme to the carbon paste electrode was verified, at a low applied potential of 20mV vs. SCE, where interfering reactions are minimized. A linear response range for 0.1 to 0.8 mmol(-1) fructose was adjusted by the equation I=0.0150(+/-0.006)+0.618(+/-0.011) [fructose], with a correlation coefficient of 0.999 and an rsd of 0.68% for n=7. The biosensor was used to determine fructose in sweets and fruit jellies and the results present good recovery, higher than 96% in both cases. A stable response is observed over two months, when stored in a refrigerator, or for 300 measurements in continuous use.
引用
收藏
页码:147 / 151
页数:5
相关论文
共 34 条
[1]   A SIMPLE AND RAPID COLORIMETRIC METHOD FOR LACTOSE DETERMINATION IN MILK [J].
ABULEHIA, IH .
FOOD CHEMISTRY, 1987, 24 (03) :233-240
[2]   CHARACTERIZATION OF MIXED ENZYME-MEDIATOR-CARBON PASTE ELECTRODES [J].
AMINE, A ;
KAUFFMANN, JM ;
GUILBAULT, GG ;
BACHA, S .
ANALYTICAL LETTERS, 1993, 26 (07) :1281-1299
[3]   NEW ELECTROCATALYTIC BIOMOLECULAR INTERFACE FOR FABRICATING A FRUCTOSE DEHYDROGENASE-BASED SENSING SYSTEM [J].
BEGUM, A ;
KOBATAKE, E ;
SUZAWA, T ;
IKARIYAMA, Y ;
AIZAWA, M .
ANALYTICA CHIMICA ACTA, 1993, 280 (01) :31-36
[4]   STUDIES ON ENZYME ELECTRODES WITH FERROCENE AND CARBON PASTE BOUND WITH CELLULOSE TRIACETATE [J].
BEH, SK ;
MOODY, GJ ;
THOMAS, JDR .
ANALYST, 1991, 116 (05) :459-462
[5]   EFFECT OF PRE-TREATMENT OF PLATINUM FOR MODIFIED PLATINUM WIRE GLUCOSE-OXIDASE AMPEROMETRIC ELECTRODES [J].
BEH, SK ;
MOODY, GJ ;
THOMAS, JDR .
ANALYST, 1989, 114 (01) :29-32
[6]  
Bradley RF, 1971, JOSLINS DIABETES MEL
[7]   AN AMPEROMETRIC GLUCOSE ELECTRODE BASED ON CARBON PASTE, CHEMICALLY MODIFIED WITH GLUCOSE-DEHYDROGENASE, NICOTINAMIDE ADENINE-DINUCLEOTIDE, AND A PHENOXAZINE MEDIATOR, COATED WITH A POLY(ESTER SULFONIC-ACID) CATION EXCHANGER [J].
BREMLE, G ;
PERSSON, B ;
GORTON, L .
ELECTROANALYSIS, 1991, 3 (02) :77-86
[8]   CARBON-FIBERS AS ELECTRODE MATERIALS FOR THE CONSTRUCTION OF PEROXIDASE-MODIFIED AMPEROMETRIC BIOSENSORS [J].
CSOREGI, E ;
GORTON, L ;
MARKOVARGA, G .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :59-70
[9]   APPLICATION OF DUAL-PULSE STAIRCASE VOLTAMMETRY FOR SIMULTANEOUS DETERMINATION OF GLUCOSE AND FRUCTOSE [J].
FUNG, YS ;
MO, SY .
ELECTROANALYSIS, 1995, 7 (02) :160-165
[10]   AMPEROMETRIC BIOSENSORS BASED ON AN APPARENT DIRECT ELECTRON-TRANSFER BETWEEN ELECTRODES AND IMMOBILIZED PEROXIDASES - PLENARY LECTURE [J].
GORTON, L ;
JONSSONPETTERSSON, G ;
CSOREGI, E ;
JOHANSSON, K ;
DOMINGUEZ, E ;
MARKOVARGA, G .
ANALYST, 1992, 117 (08) :1235-1241