Quantitative determination of UV filters in sunscreen lotions using microemulsion electrokinetic chromatography

被引:23
作者
Klampfl, CW [1 ]
Leitner, T [1 ]
机构
[1] Johannes Kepler Univ Linz, Dept Analyt Chem, A-4040 Linz, Austria
关键词
microemulsion electrokinetic chromatography; MEEKC; high performance liquid chromatography; sunscreen lotion; UV filters;
D O I
10.1002/jssc.200301413
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microemulsion electrokinetic chromatography (MEEKC) has been applied to the separation of some UV filters (Eusolex 4360, Eusolex 6300, Eusolex OCR, Eusolex 2292, Eusolex 6007, Eusolex 9020, Eusolex HMS, Eusolex OS, and Eusolex 232) commonly used in sunscreen lotions. Use of a MEEKC buffer with a mixed surfactant system to stabilize the oil droplets and an organic modifier in the aqueous phase allowed separation of most of the selected analytes in a single run in a system fitted with a diode array detector recording three wavelengths (240 nm, 300 nm, and 380 nm) simultaneously. The microemulsion employed consisted of 2.25 g of SDS, 0.75 g of Brij 35, 6.6 g 1-butanol, 0.8 g n-octane, 17.5 g 2-propanol, and 72.1 g of 10 mM borate buffer (pH 9.2). Detection limits from 0.65 to 6.0 mug/mL were obtained and the calibration plots were linear over at least one order of magnitude for all analytes. The developed method could be applied to the determination of UV filters in several sun protection products including lotions, milks, and oils. Comparison of the obtained data with those from an HPLC method described in the literature showed acceptable agreement.
引用
收藏
页码:1259 / 1262
页数:4
相关论文
共 33 条
[1]   Highly efficient and selective separations of a wide range of analytes obtained by an optimised microemulsion electrokinetic chromatography method [J].
Altria, KD .
CHROMATOGRAPHIA, 1999, 49 (7-8) :457-464
[2]   Application of microemulsion electrokinetic chromatography to the analysis of a wide range of pharmaceuticals and excipients [J].
Altria, KD .
JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) :371-386
[3]   Background theory and applications of microemulsion electrokinetic chromatography [J].
Altria, KD .
JOURNAL OF CHROMATOGRAPHY A, 2000, 892 (1-2) :171-186
[4]  
Broadbent JK, 1996, J CHROMATOGR A, V732, P101
[5]   Simultaneous determination of oxybenzone and 2-ethylhexyl 4-methoxycinnamate in sunscreen formulations by flow injection-isodifferential derivative ultraviolet spectrometry [J].
Chisvert, A ;
Salvador, A ;
Pascual-Martí, MC .
ANALYTICA CHIMICA ACTA, 2001, 428 (02) :183-190
[6]  
Furumoto T, 2001, ELECTROPHORESIS, V22, P3438, DOI 10.1002/1522-2683(200109)22:16<3438::AID-ELPS3438>3.0.CO
[7]  
2-4
[8]   Microemulsion electrokinetic chromatography - or solvent-modified micellar electrokinetic chromatography? [J].
Hansen, SH ;
Gabel-Jensen, C ;
El-Sherbiny, DTM ;
Pedersen-Bjergaard, S .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (11) :614-619
[9]  
Hansen SH, 2001, J SEP SCI, V24, P643
[10]   Separation of hydrophobic polymer additives by microemulsion electrokinetic chromatography [J].
Hilder, EF ;
Klampfl, CW ;
Buchberger, W ;
Haddad, PR .
JOURNAL OF CHROMATOGRAPHY A, 2001, 922 (1-2) :293-302