Assessing coronary blood flow dynamics with the TIMI frame count method: Comparison with simultaneous intracoronary Doppler and ultrasound

被引:28
作者
Tanedo, JS
Kelly, RF
Marquez, M
Burns, DE
Klein, LW
Costanzo, MR
Parrillo, JE
Hollenberg, SM
机构
[1] Cook Cty Hosp, Dept Cardiol, Chicago, IL 60612 USA
[2] Rush Med Coll, Cardiol Sect, Chicago, IL 60612 USA
关键词
angiography; coronary flow reserve;
D O I
10.1002/ccd.1203
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study compared the TIMI frame count (TFC), which has been proposed as a method for quantifying coronary blood flow, with coronary flow and microvascular function measured with intracoronary Doppler and intracoronary ultrasound. Coronary blood flow volume was calculated from coronary blood velocity (by intracoronary Doppler) and lumen area (by intracoronary ultrasound) in the LAD in 46 post-heart transplant patients at baseline and after intracoronary adenosine. TFC correlated significantly with average peak coronary blood velocity (r = -0.42; P = 0.004) and coronary lumen area (r = 0.39; P = 0.008), but not with coronary blood flow volume (r = -0.01; P = 0.96) or the coronary flow reserve response to adenosine (r = 0.09; P = 0.58). In conclusion, TFC is a simple method of assessing coronary blood velocity but not volumetric flow. While TFC does not predict coronary flow reserve, as a measure of velocity it does provide an assessment of basal microvascular tone, information that is complementary to that afforded by flow reserve measurements. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:459 / 463
页数:5
相关论文
共 16 条
[1]   Thrombolysis in Myocardial Infarction frame count in saphenous vein grafts [J].
Al-Mousa, EN ;
Dodge, JT ;
Rizzo, M ;
McLean, C ;
Ryan, K ;
Moynihan, J ;
Kelley, M ;
Marble, SJ ;
Goel, M ;
Daley, WL ;
Gibson, CM .
AMERICAN HEART JOURNAL, 1998, 135 (02) :323-328
[2]  
Bach Richard G., 1997, Cardiology Clinics, V15, P77, DOI 10.1016/S0733-8651(05)70320-9
[3]   Impact of injection rate on the Thrombolysis In Myocardial Infarction (TIMI) trial frame count [J].
Dodge, JT ;
Rizzo, M ;
Nykiel, M ;
Altmann, J ;
Hobkirk, K ;
Brennan, M ;
Gibson, CM .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (10) :1268-+
[4]   VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY [J].
DOUCETTE, JW ;
CORL, PD ;
PAYNE, HM ;
FLYNN, AE ;
GOTO, M ;
NASSI, M ;
SEGAL, J .
CIRCULATION, 1992, 85 (05) :1899-1911
[5]   Abnormal coronary flow in infarct arteries 1 year after myocardial infarction is predicted at 4 weeks by corrected thrombolysis in myocardial infarction (TIMI) frame count and stenosis severity [J].
French, JK ;
Ellis, CJ ;
Webber, BJ ;
Williams, BF ;
Amos, DJ ;
Ramanathan, K ;
Whitlock, RML ;
White, HD .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (06) :665-671
[6]   TIMI frame count: A quantitative method of assessing coronary artery flow [J].
Gibson, CM ;
Cannon, CP ;
Daley, WL ;
Dodge, JT ;
Alexander, B ;
Marble, SJ ;
McCabe, CH ;
Raymond, L ;
Fortin, T ;
Poole, WK ;
Braunwald, E .
CIRCULATION, 1996, 93 (05) :879-888
[7]   Relationship between TIMI frame count and clinical outcomes after thrombolytic administration [J].
Gibson, CM ;
Murphy, SA ;
Rizzo, MJ ;
Ryan, KA ;
Marble, SJ ;
McCabe, CH ;
Cannon, CP ;
Van de Werf, F ;
Braunwald, E .
CIRCULATION, 1999, 99 (15) :1945-1950
[8]  
Hollenberg SM, 1998, J HEART LUNG TRANSPL, V17, P487
[9]   EFFECTS OF INTRAAORTIC BALLOON PUMPING ON CORONARY HEMODYNAMICS AFTER CORONARY ANGIOPLASTY IN PATIENTS WITH ACUTE MYOCARDIAL-INFARCTION [J].
ISHIHARA, M ;
SATO, H ;
TATEISHI, H ;
KAWAGOE, T ;
MURAOKA, Y ;
YOSHIMURA, M .
AMERICAN HEART JOURNAL, 1992, 124 (05) :1133-1138
[10]   VALIDATION OF VOLUMETRIC FLOW MEASUREMENTS BY MEANS OF A DOPPLER-TIPPED CORONARY ANGIOPLASTY GUIDE-WIRE [J].
LABOVITZ, AJ ;
ANTHONIS, DM ;
CRAVENS, TL ;
KERN, MJ .
AMERICAN HEART JOURNAL, 1993, 126 (06) :1456-1461